Feature | Supervisor 1A | Supervisor 2 | Supervisor 2U |
Chassis Support | 6x06/6x09/6503 7603 (w/MSFC2) | 65xx, 76xx | 65xx, 76xx |
EOS | Yes | No | No |
Redundant Supervisors | Yes (Note:Must be identical models and feature cards) | Yes (Note:Must be identical models and feature cards) | Yes (Note:Must be identical models and feature cards) |
CPU | 150MHz R4700 | 250MHz RM7000 | 250MHz RM7000 |
PFC | PFC (optional) | PFC2 | PFC2 |
MSFC | MSFC/MSFC2 (opt.) | MSFC2 (opt.) | MSFC2 |
Switch Fabric | N/A | SFM or SFM2 | SFM or SFM2 |
Software Required | 5.3(1a) (Hybrid) 12.0(7)XE (Native) | 6.1(1d)(Hybrid) 12.1(8a)E(Native) | |
Fixed Uplinks | (2) GBIC | (2) GBIC | (2) GBIC |
Modular Uplinks | No | No | No |
Onboard GE Queues | 1p1q4t(Rx)/1p2q2t(Tx) | 1p1q4t(Rx)/1p2q2t(Tx) | 1p1q4t(Rx)/1p2q2t(Tx) |
Backplane Connection(s) | 32 Gbps | 32 and 256 Gbps | 32 and 256 Gbps |
Flash Slot | (1) PCMCIA | (1) PCMCIA | (1) PCMCIA |
Flash Card Capacity | 16, 24MB(16MB def.) | 16, 24MB (16MB def), 64MB FD | 16, 24MB (16MB def), 64MB FD |
Onboard Flash Capacity | 16 MB | 32 MB | 32 MB |
Default DRAM | 128 MB | 256MB | 256MB |
Maximum DRAM | 128 MB | 512 MB | 512 MB |
DRAM Slots | 1 | 1 | 1 |
NVRAM | 256 KB | 512 KB | 512 KB |
Power Supply | Any | Any | Any |
Console/Aux Port | RJ-45 CON/AUX | RJ-45 CON | RJ-45 CON |
Max # of MAC Addresses | 128000 | 128000 | 128000 |
Dimensions (H/W/D) | 1.6 x 15.3 x 16.3 in. (4.0 x 37.9 x 40.3 cm) | 1.6 x 15.3 x 16.3 in. (4.0 x 37.9 x 40.3 cm) | 1.6 x 15.3 x 16.3 in. (4.0 x 37.9 x 40.3 cm) |
Operating Temperature | 32 to 104° F (0 to 40° C) | 32 to 104° F (0 to 40° C) | 32 to 104° F (0 to 40° C) |
Storage Temperature | -40 to 167° F (-40 to 75° C) | -40 to 167° F (-40 to 75° C) | -40 to 167° F (-40 to 75° C) |
Relative Humidity | 10% to 90%, non-condensing | 10% to 90%, non-condensing | 10% to 90%, non-condensing |
Notes - Supervsior (1st and 2nd Gen):
The "optional" PFC on the Supervisor 1A may not be added as a FRU - it must be ordered that way from the factory. Only the MSFC is truly modular - PFC addition to the Supervisor 1A requires a trade-in.
Sup2 units with bootrom v7.1(1) or later and 12.1(8a)EX (Native) software may use flash disks. Sup2 units shipped prior to January 2001 shipped with 16Mb default onboard flash. 32Mb requires 6.1(3) bootrom's.
If doing DFC's on the WS-X65xx or WS-68xx linecards, 256Mb DRAM on the SUP2 is required.
Default memory on the Sup2 increased from 128MB to 256MB on August 1, 2004.
PFC has 16,000 entries for both QoS and ACL's, while PFC2 has 32,000 for QoS and 32,000 for ACL.