Catalyst 6000 Supervisors - 1st and 2nd Generation Supervisors

From NesevoWiki
Revision as of 14:22, 29 September 2008 by Florian (talk | contribs) (New page: {| border = "1" ||Feature ||Supervisor 1A ||Supervisor 2 ||Supervisor 2U |- ||Chassis Support ||6x06/6x09/6503 7603 (w/MSFC2) ||65xx, 76xx ||65xx, 76xx |- ||EOS ||Yes ||No ||No |- ||Redund...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search
Feature Supervisor 1A Supervisor 2 Supervisor 2U
Chassis Support 6x06/6x09/6503 7603 (w/MSFC2) 65xx, 76xx 65xx, 76xx
EOS Yes No No
Redundant Supervisors Yes (Note:Must be identical models and feature cards) Yes (Note:Must be identical models and feature cards) Yes (Note:Must be identical models and feature cards)
CPU 150MHz R4700 250MHz RM7000 250MHz RM7000
PFC PFC (optional) PFC2 PFC2
MSFC MSFC/MSFC2 (opt.) MSFC2 (opt.) MSFC2
Switch Fabric N/A SFM or SFM2 SFM or SFM2
Software Required 5.3(1a) (Hybrid) 12.0(7)XE (Native) 6.1(1d)(Hybrid) 12.1(8a)E(Native)
Fixed Uplinks (2) GBIC (2) GBIC (2) GBIC
Modular Uplinks No No No
Onboard GE Queues 1p1q4t(Rx)/1p2q2t(Tx) 1p1q4t(Rx)/1p2q2t(Tx) 1p1q4t(Rx)/1p2q2t(Tx)
Backplane Connection(s) 32 Gbps 32 and 256 Gbps 32 and 256 Gbps
Flash Slot (1) PCMCIA (1) PCMCIA (1) PCMCIA
Flash Card Capacity 16, 24MB(16MB def.) 16, 24MB (16MB def), 64MB FD 16, 24MB (16MB def), 64MB FD
Onboard Flash Capacity 16 MB 32 MB 32 MB
Default DRAM 128 MB 256MB 256MB
Maximum DRAM 128 MB 512 MB 512 MB
DRAM Slots 1 1 1
NVRAM 256 KB 512 KB 512 KB
Power Supply Any Any Any
Console/Aux Port RJ-45 CON/AUX RJ-45 CON RJ-45 CON
Max # of MAC Addresses 128000 128000 128000
Dimensions (H/W/D) 1.6 x 15.3 x 16.3 in. (4.0 x 37.9 x 40.3 cm) 1.6 x 15.3 x 16.3 in. (4.0 x 37.9 x 40.3 cm) 1.6 x 15.3 x 16.3 in. (4.0 x 37.9 x 40.3 cm)
Operating Temperature 32 to 104° F (0 to 40° C) 32 to 104° F (0 to 40° C) 32 to 104° F (0 to 40° C)
Storage Temperature -40 to 167° F (-40 to 75° C) -40 to 167° F (-40 to 75° C) -40 to 167° F (-40 to 75° C)
Relative Humidity 10% to 90%, non-condensing 10% to 90%, non-condensing 10% to 90%, non-condensing


Notes - Supervsior (1st and 2nd Gen):
The "optional" PFC on the Supervisor 1A may not be added as a FRU - it must be ordered that way from the factory. Only the MSFC is truly modular - PFC addition to the Supervisor 1A requires a trade-in.
Sup2 units with bootrom v7.1(1) or later and 12.1(8a)EX (Native) software may use flash disks. Sup2 units shipped prior to January 2001 shipped with 16Mb default onboard flash. 32Mb requires 6.1(3) bootrom's.
If doing DFC's on the WS-X65xx or WS-68xx linecards, 256Mb DRAM on the SUP2 is required.
Default memory on the Sup2 increased from 128MB to 256MB on August 1, 2004.
PFC has 16,000 entries for both QoS and ACL's, while PFC2 has 32,000 for QoS and 32,000 for ACL.