Catalyst 5000 - Switching Fabric Only Supervisors
From NesevoWiki
Jump to navigationJump to searchFeature | Supervisor III | Supervisor III F | Supervisor III G |
EOS Status | July 30, 2003 | April 15, 2000 | July 30, 2003 |
Chassis Support | All but 5002 with 155W Power | All | All |
Redundant Supervisors | Yes | Yes | Yes |
Processor | 150MHz R4700 RISC | IDT RISC (Similar to SupII) | 37.5MHz Motorola MCF5102 |
Modular NFFC-II | Yes (A and II-A)* | Yes | Integrated |
Modular RSFC | No | No | Yes |
Fixed Uplinks | None | (2)1000BaseSX (2)1000BaseLX | (2)GBIC |
Modular Uplinks No No | (2/4)100BaseTX, (2/4)100BaseFX, (2)1000BaseSX, (2)1000BaseLX | No | No |
Backplane Connection | 3.6 Gbps | 3.6 Gbps | 3.6 Gbps |
PCMCIA Flash | Yes | No | No |
Default Flash | 8 MB | 8 MB | 8 MB |
Default DRAM | 64 MB | 32 MB | 32 MB |
NVRAM | 512 KB | 512 KB | 512 KB |
Console Port | RJ-45 | RJ-45 | RJ-45 |
Auxiliary Port | RJ-45 | RJ-45 | RJ-45 |
FE Management Interface | Yes | Yes | Yes |
EtherChannel on Uplinks FEC No No | FEC | No | No |
Max # of MAC Addresses | 16000 | 16000 | 16000 |
Max VLANs | 1024 | 1024 | 1024 |
Dimensions | 1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm) | 1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm) | 1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm) |
Operating Temperature Range | 32 to 104 Deg. F (0 to 40 Deg. C) | 32 to 104 Deg. F (0 to 40 Deg. C) | 32 to 104 Deg. F (0 to 40 Deg. C) |
Storage Temperature Range | -40 to 167 Deg. F (-40 to 75 Deg. C) | -40 to 167 Deg. F (-40 to 75 Deg. C) | -40 to 167 Deg. F (-40 to 75 Deg. C) |
Relative Humidity | 10% to 90%, noncondensing | 10% to 90%, noncondensing | 10% to 90%, noncondensing |
Note: Older versions of the Supervisor III came with NFFC's or NFFC-II's, instead of the newer NFFC-A and
NFFC-IIA's. Some even older ones even came without a NFFC at all, and these models were quickly EOS'd.
Part Number | Description | Software Req'd | |
WS-X5005 | Supervisor I (100BaseFX, Singlemode) | 1.1 | |
WS-X5006 | Supervisor I (100BaseFX, Multimode) | 1.1 | |
WS-X5009 | Supervisor I (100BaseTX) | 1.1 | |
WS-X5505 | Supervisor II (100BaseFX, Singlemode) | 2.2 (1) | |
WS-X5506 | Supervisor II (100BaseFX, Multimode) | 2.2 (1) | |
WS-X5509 | Supervisor II (100BaseTX) | 2.2 (1) | |
WS-X5530-E1 | Supervisor III | 3.1(1) | |
WS-X5530-E2 | Supervisor III with NFFC | 4.1(1) | |
WS-X5530-E2A | Supervisor III with NFFC-A | 4.5(4) | |
WS-X5530-E3 | Supervisor III with NFFC II | 4.3(1) | |
WS-X5530-E3A | Supervisor III with NFFC II-A | 4.5(4) | |
WS-X5534-E1-GESX | Supervisor III F (1000BaseSX) | 4.3(1a) | |
WS-X5534-E1-GELX | Supervisor III F (1000BaseLX) | 4.3(1a) | |
WS-X5540 | Supervisor II G | 5.1(1a) | |
WS-X5550 | Supervisor III G | 5.1(1a) |
Supervisor Redundancy
Supervisor Redundancy requires a 5500 series chassis (5505, 5509, 5500) and one of the following |
combinations: |
Two Supervisor Engine IIs |
Two Supervisor Engine IIIs with EARL 1 |
Two Supervisor Engine IIIs with the NFFC/NFFC-A |
Two Supervisor Engine IIIs with the NFFC II/II-A |
Two Supervisor Engine III Fs with EARL 1 |
Two Supervisor Engine III Fs with NFFC/NFFC-A |
Two Supervisor Engine III Fs with NFFC II/II-A |
Two Supervisor Engine II Gs without the RSFC |
Two Supervisor Engine II Gs with RSFC |
Two Supervisor Engine III Gs without the RSFC |
Two Supervisor Engine III Gs with RSFC |
One Supervisor Engine II G with the RSFC and one Supervisor Engine II G without the RSFC |
One Supervisor Engine III G with the RSFC and one Supervisor Engine III G without the RSFC |
The following redundant configurations are supported, but with the caveat that MLS is not supported for
traffic on the redundant supervisor engine ports when the supervisor engine in standby mode has the NFFC
or NFFCII. MLS is supported for traffic on the redundant supervisor engine ports when the supervisor engine
in standby mode has the NFFC-A or NFFCII-A.
Supervisor Engine III with NFFC and Supervisor Engine III with NFFC-A |
Supervisor Engine III with NFFC II and Supervisor Engine III with NFFC II-A |
Supervisor Engine III F with NFFC and Supervisor Engine III F with NFFC-A |
Supervisor Engine III F with NFFC II and Supervisor Engine III F with NFFC II-A |