Gigabit Ethernet Transceiver Modules Compatibility Matrix
From NesevoWiki
Jump to navigationJump to searchCatalyst Express 500 Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst Express 500 | WS-CE500-24LC WS-CE500-24PC WS-CE500G-12TC |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)FY |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst Express 520 | WS-CE520-8PC-K9 | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(35)EX |
WS-CE520-24LC-K9 WS-CE520-24PC-K9 WS-CE520G-24TC-K9 |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(37)EX |
Metro Ethernet Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | ||
DOM Support | Cisco IOS Release | ||||
Cisco ME 2400 | ME-2400-24TS-A | GLC-T(10/100/1000) | — | 12.2(25)EX | |
ME-2400-24TS-D | GLC-SX-MM | ||||
GLC-LH-SM | |||||
GLC-ZX-SM | |||||
GLC-BX-D | 12.2(44)SE | 12.2(25)EX | |||
GLC-BX-U | |||||
CDWM SFP |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Cisco ME 3400 | ME-3400-24TS-A | GLC-T (10/100/1000) | — | 12.2(25)EX |
ME-3400-24TS-D | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)EX | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(25)EX | ||
GLC-BX-D | 12.2(44)SE | 12.2(25)EX | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400G-12CS-A | GLC-T (10/100/1000) | — | 12.2(25)SEG1 | |
ME-3400G-12CS-D | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)SEG1 | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(25)SEG1 | ||
GLC-BX-D | 12.2(44)SE | |||
GLC-BX-U | 12.2(44)SE | |||
CWDM SFP | 12.2(44)SE | 12.2(25)SEG1 | ||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400G-2CS-A | GLC-T (10/100/1000) | — | 12.2(35)SE1 | |
GLC-SX-MM | — | |||
GLC-LH-SM | — | |||
GLC-SX-MMD | 12.2(46)SE | 12.2(35)SE1 | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(35)SE1 | ||
GLC-BX-D | 12.2(44)SE | |||
GLC-BX-U | 12.2(44)SE | |||
CWDM SFP | 12.2(44)SE | 12.2(35)SE1 | ||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400-24FS-A | GLC-T (10/100/1000) | — | 12.2(40)SE | |
GLC-SX-MM | — | |||
GLC-LH-SM | — | |||
GLC-ZX-SM | 12.2(46)SE | |||
GLC-SX-MMD | 12.2(46)SE | |||
GLC-LH-SMD | 12.2(46)SE | |||
GLC-BX-D | 12.2(44)SE | 12.2(40)SE | ||
GLC-BX-U | ||||
CWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP | 12.2(50)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400E-24TS-M | GLC-T (10/100/1000) | — | 12.2(44)EY | |
ME-3400EG-2CS-A | GLC-SX-MM | |||
ME-3400EG-12CS-M | GLC-LH-SM | |||
GLC-SX-MMD | 12.2(44)EY | 12.2(44)EY | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Cisco ME 3800X | ME-3800X-24FS-M (client ports) | GLC-T (10/100/1000) GLC-SX-MM GLC-LH-SM SFP-GE-T (10/100/1000) GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM SFP-GE-S SFP-GE-L GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) |
— 12.2(52)EY |
12.2(52)EY 12.2(52)EY |
ME-3800X-24FS-M (SFP+ ports) | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM SFP-GE-S SFP-GE-L GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) |
— 12.2(52)EY |
12.2(52)EY 12.2(52)EY |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Cisco ME 4900 Series | ME-4924-10GE | GLC-T (1000BASE-T) | — | 12.2(31)SGA |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(31)SGA | 12.2(31)SGA | ||
GLC-BX-U | ||||
CDWM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG |
Catalyst 2900 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2900 series | WS-C2980G-A | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
7.2.1 | Not supported |
WS-C2948G | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
7.2 | Not supported | |
WS-C2948G-L3 | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
7.2 | Not supported | |
Catalyst 2900 series (continued) | WS-C2948G-GE-TX | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP |
8.2(1)GLX | Not supported |
WS-C2912MF-XL with WS-X2931-XL |
WS-G5482 WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
Not supported Not supported |
12.0(5)XW 12.0(5)WC3b 12.0(5)WC5 | |
WS-C2924M-XL-EN with WS-X2931-XL | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
Not supported | 12.0(5)WC3b 12.0(5)WC5 | |
WS-C2924M-XL-EN-DC with WS-X2931-XL | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
Not supported | 12.0(5)WC3b 12.0(5)WC5 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2940 Series | WS-C2940-8TF-S | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.1(13)AY |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2950 Series | WS-C2950G-12-EI WS-C2950G-24-EI WS-C2950G-24-EI-DC WS-C2950G-48-EI |
WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC DWDM GBIC |
Not supported | 12.1(6)EA2b 12.1(12c)EA1 12.1(20)EA2 |
WS-C2950ST-8 LRE WS-C2950ST-24 LRE WS-C2950ST-24 LRE997 |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.1(19)EA1c |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2960 series | WS-C2960-24TC-L WS-C2960G-24TC-L WS-C2960-48TC-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(25)FX |
WS-C2960-24PC-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(44)SE | |
WS-C2960-24TC-S WS-C2960-48TC-S |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(37)EY | |
WS-C2960-8TC-S | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(46)SE | |
WS-C2960-48PST-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(46)SE | |
Catalyst 2960 series (continued) | WS-C2960-8TC-L WS-C2960G-8TC-L | GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(35)SE |
WS-C2960G-48TC-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(25)SEE | |
WS-C2960-48PST-S WS-C2960-24PC-S WS-C2960-24LT-S | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(50)SE |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2960-S Series | WS-C2960S-24TS-S | GLC-T (1000BASE-T) | Not supported | 12.2(53)SE1 |
WS-C2960S-48TS-S | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
WS-C2960S-48FPS-L | GLC-T (1000BASE-T) | Not supported | 12.2(53)SE1 | |
WS-C2960S-48LPS-L | GLC-SX-MM | |||
WS-C2960S-24PS-L | GLC-LH-SM | |||
WS-C2960S-48TS-L | GLC-ZX-SM | |||
WS-C2960S-24TS-L | GLC-BX-D | |||
GLC-BX-U | ||||
CWDM SFP | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
WS-C2960S-48FPD-L | GLC-SX-MM | Not supported | 12.2(53)SE1 | |
WS-C2960S-48LPD-L | GLC-LH-SM | |||
WS-C2960S-24PD-L | GLC-ZX-SM | |||
WS-C2960S-48TD-L | GLC-BX-D | |||
WS-C2960S-24TD-L | GLC-BX-U | |||
CWDM SFP | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2960-C Series | WS-C2960CG-8TC-L | GLC-SX-MM | Not supported | 12.2(55)EX1 |
GLC-SX-MMD | ||||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
WS-C2960C-8TC-S | GLC-SX-MM | Not supported | 12.2(55)EX3 | |
GLC-SX-MMD | ||||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
WS-C2960C-8TC-L | GLC-SX-MM | Not supported | 12.2(55)EX3 | |
WS-C2960C-8PC-L | GLC-SX-MMD | |||
WS-C2960C-12PC-L | GLC-LH-SM | |||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2970 series | WS-C2970G-24TS-E | GLC-T (10/100/1000) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.1(14)EA1 |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2975 Series | WS-C2975GS-48PS-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(46)EX |
Catalyst 3500 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3500XL Series | WS-C3508G-XL-EN | WS-G5482 | — | 12.0(5)XW |
WS-C3512-XL-EN | WS-G5483 | 12.0(5)WC3b | ||
WS-C3524-XL-EN | WS-G5484 | |||
WS-C3524-PWR-XL-EN | WS-G5486 | |||
WS-C3548-XL-EN | WS-G5487 | |||
CWDM GBIC |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3550 Series | WS-C3550-24-SMI | WS-G5482 | — | 12.1(6)EA1a |
WS-C3550-24-EMI | WS-G5483 | 12.1(8)EA1b | ||
WS-C3550-24-DC-SMI | WS-G5484 | |||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | 12.1(12c)EA1 | |||
DWDM GBIC | 12.1(20)EA2 | |||
WS-C3550-24-FX-SMI | WS-G5482 | — | 12.1(12c)EA1 | |
WS-C3550-24PWR-SMI | WS-G5483 | |||
WS-C3550-24PWR-EMI | WS-G5484 | |||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.1(20)EA2 | |||
WS-C3550-48-SMI | WS-G5482 | — | 12.1(8)EA1b | |
WS-C3550-48-EMI | WS-G5483 | |||
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | 12.1(12c)EA1 | |||
DWDM GBIC | 12.1(20)EA2 | |||
WS-C3550-12G | WS-G5482 | — | 12.1(6)EA1 | |
WS-C3550-12T | WS-G5483 | 12.1(8)EA1b | ||
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | 12.1(12c)EA1 | |||
DWDM GBIC | 12.1(20)EA2 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560 Series | WS-C3560-24PS | GLC-T (10/100/1000) | — | 12.1(19)EA1c |
WS-C3560-48PS | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.1(19)EA1c | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | ||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560G-24TS | GLC-T (10/100/1000) | — | 12.2(20)SE3 | |
WS-C3560G-48TS | GLC-SX-MM | |||
WS-C3560G-48PS | GLC-LH-SM | |||
WS-C3560G-24PS | GLC-SX-MMD | 12.2(46)SE | 12.2(20)SE3 | |
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | ||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560-48TS | GLC-T (10/100/1000) | — | 12.2(20)SE3 | |
WS-C3560-24TS | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(20)SE3 | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | ||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560-8PC | GLC-T (10/100/1000) | — | 12.2(35)SE | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(35)SE | ||
CWDM SFP | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
WS-C3560-12PC-S | GLC-SX-MM | — | 12.2(46)SE | |
GLC-LH-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(46)SE | ||
CWDM SFP | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
WS-C3560V2-24PS | GLC-T (10/100/1000) | — | 12.2(50)SE | |
WS-C3560V2-24TS | GLC-SX-MM | |||
WS-C3560V2-48PS | GLC-LH-SM | |||
WS-C3560V2-48TS | GLC-SX-MMD | 12.2(50)SE | 12.2(50)SE | |
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
CWDM SFP | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560-E Series | WS-C3560E-12SD | GLC-T (10/100/1000) | — | 12.2(44)SE |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(44)SE | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560E-12SD | GLC-T (10/100/1000) | — | 12.2(44)SE | |
With CVR-X2-SFP (for X2 ports) | GLC-SX-MM GLC-LH-SM |
|||
GLC-SX-MMD | 12.2(46)SE | 12.2(44)SE | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560-X Series | WS-C3560X-24T | GLC-T (10/100/1000) | — | 12.2(53)SE |
WS-C3560X-48T | GLC-SX-MM | |||
WS-C3560X-24P | GLC-LH-SM | |||
WS-C3560X-48P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3560X-48PF | GLC-LH-SMD | |||
With C3KX-NM-1G and C3KX-NM-10G (slots 1 and 3) network modules |
GLC-ZX-SM GLC-BX-D GLC-BX-U |
|||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3560X-24T | GLC-SX-MM | — | 12.2(53)SE | |
WS-C3560X-48T | GLC-LH-SM | |||
WS-C3560X-24P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3560X-48P | GLC-LH-SMD | |||
WS-C3560X-48PF | GLC-ZX-SM | |||
With C3KX-NM-10G | GLC-BX-D | |||
(slots 2 and 4) and | GLC-BX-U | |||
C3KX-SM-10G network modules | SFP-GE-S SFP-GE-L |
|||
SFP-GE-Z | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560-C Series | WS-C3560CG-8TC-S | GLC-SX-MM | — | 12.2(55)EX |
WS-C3560CG-8PC-S | GLC-SX-MMD | |||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
WS-C3560C-8PC-S | GLC-SX-MM | — | 12.2(55)EX3 | |
WS-C3560C-12PC-S | GLC-SX-MMD | |||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP |
Catalyst 3700 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst 3750-E Series | WS-C3750E-24TD | GLC-T (10/100/1000) | — | 12.2(35)SE2 |
WS-C3750E-24PD | GLC-SX-MM | |||
WS-C3750E-48TD | GLC-LH-SM | |||
WS-C3750E-48PD | GLC-SX-MMD | 12.2(46)SE | 12.2(35)SE2 | |
WS-C3750E-48PDF | GLC-LH-SMD | |||
With CVR-X2-SFP (for X2 ports) | GLC-ZX-SM GLC-BX-D |
|||
GLC-BX-U | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | ||
DOM Support | Cisco IOS Release | ||||
Catalyst 3750 series | WS-C3750G-12S | GLC-T (10/100/1000) | — | 12.1.(14)EA1 | |
WS-C3750G-24TS | GLC-SX-MM | ||||
WS-C3750G-48TS | GLC-LH-SM | ||||
WS-C3750G-24PS | GLC-SX-MMD | 12.2(46)SE | 12.1(14)EA1 | ||
WS-C3750G-48PS | GLC-LH-SMD | ||||
GLC-ZX-SM | |||||
CWDM SFP | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | |||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24TS | GLC-T (10/100/1000) | — | 12.1(14)EA1 | ||
WS-C3750-48TS | GLC-SX-MM | ||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.1(14)EA1 | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | 12.2(46)SE | 12.1(19)EA1c | |||
CWDM SFP | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | |||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24PS | GLC-T (10/100/1000) | — | 12.1(19)EA1c | ||
WS-C3750-48PS | GLC-SX-MM | ||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.1(19)EA1c | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
CWDM SFP | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | |||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24FS-S | GLC-T (10/100/1000) | — | 12.2(25)SEB | ||
GLC-SX-MM | |||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)SEB | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
CWDM SFP | |||||
GLC-BX-D | |||||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24WFS | GLC-T (1000BASE-T) | — | 12.2(25)FZ | ||
GLC-SX-MM | |||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)FZ | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
CWDM SFP | |||||
GLC-BX-D | |||||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750V2-24PS | GLC-T (10/100/1000) | — | 12.2(50)SE | ||
WS-C3750V2-24TS | GLC-SX-MM | ||||
WS-C3750V2-48PS | GLC-LH-SM | ||||
WS-C3750V2-48TS | GLC-SX-MMD | 12.2(50)SE | 12.2(50)SE | ||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
CWDM SFP | |||||
GLC-BX-D | |||||
GLC-BX-U | |||||
DWDM SFP | |||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst 3750-X Series | WS-C3750X-24T | GLC-T (10/100/1000) | — | 12.2(53)SE |
WS-C3750X-48T | GLC-SX-MM | |||
WS-C3750X-24P | GLC-LH-SM | |||
WS-C3750X-48P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3750X-48PF | GLC-LH-SMD | |||
With C3KX-NM-1G and | GLC-ZX-SM | |||
C3KX-NM-10G (slots 1 and 3) network modules |
GLC-BX-D GLC-BX-U |
|||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3750X-24T | GLC-SX-MM | — | 12.2(53)SE | |
WS-C3750X-48T | GLC-LH-SM | |||
WS-C3750X-24P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3750X-48P | GLC-LH-SMD | |||
WS-C3750X-48PF | GLC-ZX-SM | |||
With C3KX-NM-10G | GLC-BX-D | |||
(slots 2 and 4) and | GLC-BX-U | |||
C3KX-SM-10G network modules | CWDM SFP SFP-GE-S |
|||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3750X-12S | GLC-T (10/100/1000) | — | 12.2(58)SE1 | |
WS-C3750X-24S | GLC-SX-MM | |||
Client ports and uplink | GLC-LH-SM | |||
ports with C3KX-NM-1G and C3KX-NM-10G | GLC-SX-MMD GLC-LH-SMD |
12.2(58)SE1 | 12.2(58)SE1 | |
(slots 1 and 3) network modules | GLC-ZX-SM GLC-BX-D |
|||
GLC-BX-U | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3750X-12S | GLC-SX-MM | — | 12.2(58)SE1 | |
WS-C3750X-24S | GLC-LH-SM | |||
Uplink ports with | GLC-SX-MMD | 12.2(58)SE1 | 12.2(58)SE1 | |
C3KX-NM-10G (slots 2 and 4) and C3KX-SM-10G network modules | GLC-LH-SMD GLC-ZX-SM GLC-BX-D |
|||
GLC-BX-U | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) |
Industrial Ethernet and Smart Grid Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Cisco 2500 Connected Grid Switch Series | CGS-2520-24TC CGS-2520-16S-8PC |
GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD GLC-BX-D GLC-BX-U SFP-GE-S SFP-GE-L GLC-EX-SMD SFP-GE-Z CWDM SFP |
Not supported | 12.2(53)EX |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Cisco 2000 Connected Grid Router Series | CGR 2010 | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD |
Not supported | 15.1(1)T |
Catalyst 4500 Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Cisco IOS Support | DOM Support | |||
Catalyst 4500 series | WS-X4013 | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CDWM GBIC |
Not supported | — |
WS-X4013+ | WS-G5483 | 12.1(19)EW | — | |
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CDWM GBIC | ||||
DWDM GBIC | 12.1(19)EW | |||
WS-X4013+TS | GLC-SX-MM | 12.2(20)EWA | — | |
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(20)EWA | 12.2(20)EWA | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG | ||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4013+10GE | GLC-SX-MM | 12.2(25)SG | — | |
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(25)SG | 12.2(25)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG | ||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4014 | WS-G5483 | 12.1(13)EW | — | |
WS-X4232-GB-RJ | WS-G5484 | 12.1(8a)EW | — | |
WS-X4306-GB | WS-G5486 | |||
WS-X4412-2GB-T | WS-G5487 | |||
CWDM GBIC | 12.1(12c)EW | — | ||
DWDM GBIC | 12.1(19)EW | 12.2(19)EW | ||
WS-X4418-GB | WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
12.1(8a)EW 12.1(12c)EW |
— — | |
DWDM GBIC | 12.1(19)EW | 12.2(19)EW | ||
WS-X4302-GB | WS-G5483 | 12.1(19)EW | — | |
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.1(19)EW | 12.2(19)EW | ||
WS-4448-GB-SFP | GLC-T (1000BASE-T) | 12.2(20)EW | — | |
GLC-SX-MM | — | |||
GLC-LH-SM | — | |||
GLC-ZX-SM | — | |||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
CWDM SFP | 12.2(20)EW | 12.2(20)EW | ||
GLC-BX-D | 12.2(20)EWA | 12.2(20)EWA | ||
GLC-BX-U | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4506-GB-T | GLC-SX-MM | 12.2(20)EWA | — | |
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(20)EWA | 12.2(20)EWA | ||
GLC-BX-U | ||||
CWDM SFP | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4515 | WS-G5483 | 12.1(13)EW | — | |
WS-G5484 | 12.1(12c)EW | — | ||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.1(19)EW | 12.1(19)EW | ||
WS-X4516 | WS-G5483 | 12.2(18)EW | — | |
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.2(18)EW | 12.2(18)EW | ||
WS-X4516-10GE | GLC-T (1000BASE-T) | 12.2(25)EWA | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(25)EWA | 12.2(25)EWA | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG | ||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X45-SUP6-E | GLC-T | 12.2(40)SG | — | |
WS-X4606-X2 | GLC-SX-MM | |||
with CVR-X2-SFP Twin | GLC-LH-SM | |||
Gig converter | GLC-ZX-SM | |||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(40)SG | 12.2(40)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-4624-SFP-E | GLC-T (1000BASE-T) | 12.2(44)SG | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(44)SG | 12.2(44)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X45-SUP6L-E | GLC-T (1000BASE-T) | 12.2(52)SG | — | |
with CVR-X2-SFP Twin | GLC-SX-MM | |||
Gig converter | GLC-LH-SM | |||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(52)SG | 12.2(52)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4612-SFP-E | GLC-T (1000BASE-T) | 12.2(54)SG | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(54)SG | 12.2(54)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4640-CSFP-E | GLC-T (1000BASE-T) | 15.0(2)SG | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 15.0(2)SG | 15.0(2)SG | ||
GLC-2BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4712-SFP+E | GLC-T (1000BASE-T) | 3.1.0SG | — | |
WS-X45-SUP7-E | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 3.1.0SG | 3.1.0SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X45-SUP7L-E | GLC-T (1000BASE-T) | 3.2.0XO | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 3.2.0XO | 3.2.0XO | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG |