Cisco 6503 and Cisco 6503-E
Video Datasheet
Cisco Catalyst 6503-E Datasheet
Supervisor engines
Both, the Cisco WS-C6503 and the Cisco WS-C6503-E switch have three horizontal slots being numbered from 1 (top) to 3 (bottom)
Supported supervisor engines in the Cisco WS-C6503 switch
- Supports Supervisor Engine 2
- Supervisor Engine 32
- WS-SUP32-GE-3B
- WS-SUP32-10GE-3B
- WS-S32-GE-PISA
- WS-S32P-10GE-PISA
- Supervisor Engine 720
- WS-SUP720
- WS-SUP720-3B
- WS-SUP720-3BXL
- VS-S720-10G-3C
- VS-S720-10G-3CXL
- WS-SUP720
Note: Redundant supervisor engines must be configured identically.
Supported supervisor engines in the Cisco WS-C6503-E switch
- Supports Supervisor Engine 2
- Supervisor Engine 32
- WS-SUP32-GE-3B
- WS-SUP32-10GE-3B
- WS-S32-GE-PISA
- WS-S32P-10GE-PISA
- Supervisor Engine 720
- WS-SUP720
- WS-SUP720-3B
- WS-SUP720-3BXL
- VS-S720-10G-3C
- VS-S720-10G-3CXL
- WS-SUP720
Note: Redundant supervisor engines must be configured identically.
Fan trays
Supported Fan trays in the 6503 series
- Standard Fan tray
- FAN-MOD-3
- High-speed fan tray
- FAN-MOD-3HS
Note The standard fan tray will only support WS-X6K-S2-PFC2, WS-X6K-S2-MSFC2 and WS-X6K-S2U-MSFC2. Supervisor Engin 32 and 720 will need a high-speed fan tray
Supported Fan trays in the 6503-E series
- WS-C6503-E-FAN
Note: The WS-C6503-E-Fan ist a high-speed fan tray.
Power supplies and power entry modules
Both, the Cisco 6503 and the Cisco 6503-E switch have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.
Supported spower supplies in the Cisco 6503 switch
- 950 W AC-input power supply
- PWR-950-AC
!!! Note: the power entry module PEM-15A-AC is needed when using a PWR-950-AC. You need one PEM-15A-AC per PWR-950-AC.
- 950 W DC-input power supply
- PWR-950-DC
!!! Note: the power entry module PEM-DC/3 is needed when using a PWR-950-DC. You need one PEM-DC/3 per PWR-950-DC.
- 1400 W AC-input power supply
- PWR-1400-AC
!!! Note: the power entry module PEM-20A-AC+ is needed when using a PWR-1400-AC. You need one PEM-20A-AC+ per PWR-1400-AC.
Supported spower supplies in the Cisco 6503-E switch
- 950 W AC-input power supply
- PWR-950-AC
!!! Note: the power entry module PEM-15A-AC is needed when using a PWR-950-AC. You need one PEM-15A-AC per PWR-950-AC.
- 950 W DC-input power supply
- PWR-950-DC
!!! Note: the power entry module PEM-DC/3 is needed when using a PWR-950-DC. You need one PEM-DC/3 per PWR-950-DC.
- 1400 W AC-input power supply
- PWR-1400-AC
!!! Note: the power entry module PEM-20A-AC+ is needed when using a PWR-1400-AC. You need one PEM-20A-AC+ per PWR-1400-AC.