Cisco 6503 and Cisco 6503-E
Supervisor engines
Both, the Cisco6503 and the Cisco6503-E switch have three horizontal slots being numbered from 1 (top) to 3 (bottom)
Supported supervisor engines in the Cisco6503 switch
- Supports Supervisor Engine 2
- Supervisor engines are installed in slot 1 and slot 2.
- Supervisor Engine 32 and Supervisor Engine 720.
- Using a Supervisor Engine 32 or a Supervisor Engine 720 requires that you install the optional high-speed fan tray.
Note: Redundant supervisor engines must be configured identically.
Supported supervisor engines in the Cisco6503-E switch
- Supports Supervisor Engine 2
- Supervisor Engine 32
- Supervisor Engine 720.
Note: Redundant supervisor engines must be configured identically.
Fan trys
Supported Fan trays in the 6503 series
- Standard Fan try
- FAN-MOD-3
- High-speed fan tray
- FAN-MOD-3HS
Note Both fan tray models contain four individual fans. The individual fans are not field replaceable; you must replace the fan tray.
Supported Fan trays in the 6503-E series
- WS-C6503-E-FAN
Note The fan tray contains four individual fans. The individual fans are not field replaceable; you must replace the fan tray.
Power supplies and power entry modules
Both, the Cisco 6503 and the Cisco 6503-E switch have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.
Supported spower supplies in the Cisco 6503 switch
- 950 W AC-input power supply
- PWR-950-AC
!!! Note: the power entry module PEM-15A-AC is needed when using a PWR-950-AC. You need one PEM-15A-AC per PWR-950-AC.
- 950 W DC-input power supply
- PWR-950-DC
!!! Note: the power entry module PEM-DC/3 is needed when using a PWR-950-DC. You need one PEM-DC/3 per PWR-950-DC.
- 1400 W AC-input power supply
- PWR-1400-AC
!!! Note: the power entry module PEM-20A-AC+ is needed when using a PWR-1400-AC. You need one PEM-20A-AC+ per PWR-1400-AC.
Supported spower supplies in the Cisco 6503-E switch
- 950 W AC-input power supply
- PWR-950-AC
!!! Note: the power entry module PEM-15A-AC is needed when using a PWR-950-AC. You need one PEM-15A-AC per PWR-950-AC.
- 950 W DC-input power supply
- PWR-950-DC
!!! Note: the power entry module PEM-DC/3 is needed when using a PWR-950-DC. You need one PEM-DC/3 per PWR-950-DC.
- 1400 W AC-input power supply
- PWR-1400-AC
!!! Note: the power entry module PEM-20A-AC+ is needed when using a PWR-1400-AC. You need one PEM-20A-AC+ per PWR-1400-AC.