Line 42: Line 42:
 
*950 watt AC-input power supply<br/>
 
*950 watt AC-input power supply<br/>
 
**PWR-950-AC<br/>
 
**PWR-950-AC<br/>
''Note: the power entry module '''PEM-15A-AC ''' is needed when using a PWR-950-AC. You need one '''PEM-15A-AC ''' per PWR-950-AC.<br/>''
+
''!!!Note: the power entry module '''PEM-15A-AC ''' is needed when using a PWR-950-AC. You need one '''PEM-15A-AC ''' per PWR-950-AC.<br/>''
 
''The power entry modules are installed on the front of the chassis on the very top.''
 
''The power entry modules are installed on the front of the chassis on the very top.''
  
 
*950 watt DC-input power supply<br/>
 
*950 watt DC-input power supply<br/>
 
**PWR-950-DC<br/>
 
**PWR-950-DC<br/>
''Note: the power entry module '''PEM-DC/3''' is needed when using a PWR-950-DC. You need one '''PEM-DC/3''' per PWR-950-DC.<br/>''
+
''!!!Note: the power entry module '''PEM-DC/3''' is needed when using a PWR-950-DC. You need one '''PEM-DC/3''' per PWR-950-DC.<br/>''
 
''The power entry modules are installed on the front of the chassis on the very top.''
 
''The power entry modules are installed on the front of the chassis on the very top.''
  
 
*1400 watt AC-input power supply<br/>
 
*1400 watt AC-input power supply<br/>
 
**PWR-1400-AC<br/>
 
**PWR-1400-AC<br/>
''Note: the power entry module '''PEM-20A-AC+''' is needed when using a PWR-1400-AC. You need one '''PEM-20A-AC+''' per PWR-1400-AC.<br/>''
+
''!!!Note: the power entry module '''PEM-20A-AC+''' is needed when using a PWR-1400-AC. You need one '''PEM-20A-AC+''' per PWR-1400-AC.<br/>''
 
''The power entry modules are installed on the front of the chassis on the very top.''
 
''The power entry modules are installed on the front of the chassis on the very top.''
  

Revision as of 07:47, 30 April 2008

Supervisor engines

Both, the Cisco7603 and the Cisco7603-S router have three horizontal slots being numbered from top to bottom.
While slot 1 is reserved for the supervisor engine, slot 2 can contain an optional redundant supervisor engine.
When installing a redundant supervisor engine, both supervisor engines must be identical.
The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by

Supported supervisor engines in the Cisco7603 router

  • Supervisor engine 2
    • WS-X6K-S2-PFC2
    • WS-X6K-S2-MSFC2
    • WS-X6K-S2U-MSFC2
  • Supervisor engine 720
    • WS-SUP720
    • WS-SUP720-3B
    • WS-SUP720-3BXL

While being supported in the WS-C6503 and WS-C6503-E chassis, the supervisor engine 32 is not supported in the ciso7603 router

Supported supervisor engines in the Cisco7603-S router

  • Supervisor engine 32
    • WS-SUP32-GE-3B
    • WS-SUP32-10GE-3B
  • Supervisor engine 720
    • WS-SUP720
    • WS-SUP720-3B
    • WS-SUP720-3BXL
  • Route switch processor 720
    • RSP720-3C-GE
    • RSP720-3CXL-GE

the supervisor engine 2 is not longer supported in the Cisco7603-S router.

Power supplies

Both, the Cisco7603 and the Cisco7603-S router have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.

Supported spower supplies in the Cisco7603 router

  • 950 watt AC-input power supply
    • PWR-950-AC

!!!Note: the power entry module PEM-15A-AC is needed when using a PWR-950-AC. You need one PEM-15A-AC per PWR-950-AC.
The power entry modules are installed on the front of the chassis on the very top.

  • 950 watt DC-input power supply
    • PWR-950-DC

!!!Note: the power entry module PEM-DC/3 is needed when using a PWR-950-DC. You need one PEM-DC/3 per PWR-950-DC.
The power entry modules are installed on the front of the chassis on the very top.

  • 1400 watt AC-input power supply
    • PWR-1400-AC

!!!Note: the power entry module PEM-20A-AC+ is needed when using a PWR-1400-AC. You need one PEM-20A-AC+ per PWR-1400-AC.
The power entry modules are installed on the front of the chassis on the very top.

Supported spower supplies in the Cisco7603-S router

  • 1500 watt DC-input power supply
    • PWR-1500-DC

!!! Note: the power entry module PEM-1500W-DC/03S is needed when using a PWR-1500-DC. You need one PEM-1500W-DC/03S per PWR-1500-DC.
The power entry modules are installed on the front of the chassis on the very top.
There is no longer an AC power supply option for the Cisco7603-S router