Difference between revisions of "Cisco 6506 and Cisco 6506-E"

From NesevoWiki
Jump to navigationJump to search
 
(11 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
Both, The Cisco Catalyst 6506 switch and the Cisco Catalyst 6506-E switch have 6-slot horizontal slots and being nummbered from 1 (botton) to 6 (top).
 
Both, The Cisco Catalyst 6506 switch and the Cisco Catalyst 6506-E switch have 6-slot horizontal slots and being nummbered from 1 (botton) to 6 (top).
 
<br>
 
<br>
 +
==Video Datasheet==
 +
[http://www.youtube.com/watch?v=QXfDuNUCLlQ Cisco Catalyst 6506-E Datasheet ]
 
==Supervisor engines==
 
==Supervisor engines==
'''Supported supervisor engines in the Cisco6506 switch'''
+
'''Supported supervisor engines in the Cisco  WS-C6506 switch'''
<br/>
+
<br/><br/>
*Supervisor Engine 2
+
'''Note:''' Supervisor Engine 2 is installed in slot 1 or slot 2. Supervisor Engine 32 and Supervisor Engine 720 are installed in slot 5 or slot 6.
*Supervisor Engine 32 and Supervisor Engine 720
+
<br/><br/>
*Supervisor Engine 32 and Supervisor Engine 720 require that you install the high-speed fan tray.
+
*Supports Supervisor Engine 2
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-PFC2]]<br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-MSFC2]] <br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2U-MSFC2]] <br/>
 +
 
 +
*Supervisor Engine 32  
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B]]
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]]
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32-GE-PISA]]
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32P-10GE-PISA]]
 +
 
 +
*Supervisor Engine 720
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]] <br/>
 +
** VS-S720-10G-3C
 +
** VS-S720-10G-3CXL
 
<br/>
 
<br/>
 
'''''Note:''''' Redundant supervisor engines must be configured identically.
 
'''''Note:''''' Redundant supervisor engines must be configured identically.
 
<br/><br/>
 
<br/><br/>
'''Supported supervisor engines in the Cisco6506-E switch'''
+
'''Supported supervisor engines in the Cisco WS-C6506-E switch'''
 
<br>
 
<br>
*Supervisor Engine 2  
+
*Supports Supervisor Engine 2
*Supervisor Engine 32 and Supervisor Engine 720
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-PFC2]]<br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-MSFC2]] <br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2U-MSFC2]] <br/>
 +
 
 
*Supervisor Engine 32  
 
*Supervisor Engine 32  
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B ]]
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]]
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32-GE-PISA]]
 +
**[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32P-10GE-PISA]]
 +
 
*Supervisor Engine 720
 
*Supervisor Engine 720
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/>
 +
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]] <br/>
 +
** VS-S720-10G-3C
 +
** VS-S720-10G-3CXL
 
<br/>
 
<br/>
 
'''''Note:''''' Redundant supervisor engines must be configured identically.
 
'''''Note:''''' Redundant supervisor engines must be configured identically.
 
<br/><br/>
 
<br/><br/>
==Fan trys ==
+
 
'''Supported Fan trays in the 6506 series'''
+
==Fan trays ==
 +
'''Supported Fan trays in the WS-C6506 series'''
 
<br/>
 
<br/>
 
* Standard fan tray
 
* Standard fan tray
Line 27: Line 59:
 
** WS-C6K-6SLOT-FAN2
 
** WS-C6K-6SLOT-FAN2
 
<br/>
 
<br/>
'''Supported Fan trys in the 6506 series'''
+
'''''Note''''' The standard fan tray will only support WS-X6K-S2-PFC2, WS-X6K-S2-MSFC2 and WS-X6K-S2U-MSFC2. Supervisor Engin 32 and 720 will need a high-speed fan tray
 +
<br/><br/>
 +
'''Supported Fan trys in the WS-C6506-E series'''
 
<br/>
 
<br/>
 
*one hot-swappable fan tray
 
*one hot-swappable fan tray
**WS-C6506-E-FAN—564 CFM
+
**WS-C6506-E-FAN
 
<br/>
 
<br/>
==Power supplies and power entry modules==
+
'''''Note:''''' The WS-C6506-E-Fan ist a high-speed fan tray.
Both, the Cisco 6503 and the Cisco 6506-E switch have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.<br/>
+
 
 +
==Power supplies==
 +
Both, the Cisco WS-C6506 and the Cisco 6506-E switch have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.<br/>
 
<br/>
 
<br/>
'''Supported spower supplies in the Cisco 6506 switch'''
+
'''Supported spower supplies in the Cisco WS-C6506 switch'''
 
<br/>
 
<br/>
 
* 1000 W AC-input power supply
 
* 1000 W AC-input power supply
Line 60: Line 96:
 
** WS-CAC-8700W
 
** WS-CAC-8700W
 
<br/>
 
<br/>
'''Supported spower supplies in the Cisco 6506-E switch'''
+
'''Supported spower supplies in the Cisco WS-C6506-E switch'''
 
<br/>
 
<br/>
 
* 2500 W AC-input power supply
 
* 2500 W AC-input power supply

Latest revision as of 11:03, 15 July 2009

Both, The Cisco Catalyst 6506 switch and the Cisco Catalyst 6506-E switch have 6-slot horizontal slots and being nummbered from 1 (botton) to 6 (top).

Video Datasheet

Cisco Catalyst 6506-E Datasheet

Supervisor engines

Supported supervisor engines in the Cisco WS-C6506 switch

Note: Supervisor Engine 2 is installed in slot 1 or slot 2. Supervisor Engine 32 and Supervisor Engine 720 are installed in slot 5 or slot 6.


Note: Redundant supervisor engines must be configured identically.

Supported supervisor engines in the Cisco WS-C6506-E switch


Note: Redundant supervisor engines must be configured identically.

Fan trays

Supported Fan trays in the WS-C6506 series

  • Standard fan tray
    • WS-C6K-6SLOT-FAN
  • High- Speed fan tray
    • WS-C6K-6SLOT-FAN2


Note The standard fan tray will only support WS-X6K-S2-PFC2, WS-X6K-S2-MSFC2 and WS-X6K-S2U-MSFC2. Supervisor Engin 32 and 720 will need a high-speed fan tray

Supported Fan trys in the WS-C6506-E series

  • one hot-swappable fan tray
    • WS-C6506-E-FAN


Note: The WS-C6506-E-Fan ist a high-speed fan tray.

Power supplies

Both, the Cisco WS-C6506 and the Cisco 6506-E switch have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.

Supported spower supplies in the Cisco WS-C6506 switch

  • 1000 W AC-input power supply
    • WS-CAC-1000W
  • 1300 W AC-input power supply
    • WS-CAC-1300W
  • 1300 W DC-input power supply
    • WS-CDC-1300W
  • 2500 W AC-input power supply
    • WS-CAC-2500W
  • 2500 W DC-input power supply
    • WS-CDC-2500W
  • 3000 W AC-input power supply
    • WS-CAC-3000W
  • 4000 W AC-input power supply
    • WS-CAC-4000W-US
  • 4000 W AC-input power supply
    • WS-CAC-4000W-INT
  • 4000 W DC-input power supply
    • PWR-4000-DC
  • 6000 W AC-input power supply
    • WS-CAC-6000W
  • 8700 W AC-input power supply
    • WS-CAC-8700W


Supported spower supplies in the Cisco WS-C6506-E switch

  • 2500 W AC-input power supply
    • WS-CAC-2500W
  • 2500 W DC-input power supply
    • WS-CDC-2500W
  • 3000 W AC-input power supply
    • WS-CAC-3000W
  • 4000 W AC-input power supply
    • WS-CAC-4000W-US
  • 4000 W AC-input power supply
    • WS-CAC-4000W-INT
  • 4000 W DC-input power supply
    • PWR-4000-DC
  • 6000 W AC-input power supply
    • WS-CAC-6000W
  • 8700 W AC-input power supply
    • WS-CAC-8700W-E