Difference between revisions of "Cisco 6506 and Cisco 6506-E"
(13 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
Both, The Cisco Catalyst 6506 switch and the Cisco Catalyst 6506-E switch have 6-slot horizontal slots and being nummbered from 1 (botton) to 6 (top). | Both, The Cisco Catalyst 6506 switch and the Cisco Catalyst 6506-E switch have 6-slot horizontal slots and being nummbered from 1 (botton) to 6 (top). | ||
<br> | <br> | ||
+ | ==Video Datasheet== | ||
+ | [http://www.youtube.com/watch?v=QXfDuNUCLlQ Cisco Catalyst 6506-E Datasheet ] | ||
==Supervisor engines== | ==Supervisor engines== | ||
− | '''Supported supervisor engines in the | + | '''Supported supervisor engines in the Cisco WS-C6506 switch''' |
− | <br/> | + | <br/><br/> |
− | + | '''Note:''' Supervisor Engine 2 is installed in slot 1 or slot 2. Supervisor Engine 32 and Supervisor Engine 720 are installed in slot 5 or slot 6. | |
− | + | <br/><br/> | |
− | *Supervisor Engine 32 | + | *Supports Supervisor Engine 2 |
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-PFC2]]<br/> | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-MSFC2]] <br/> | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2U-MSFC2]] <br/> | ||
+ | |||
+ | *Supervisor Engine 32 | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B]] | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]] | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32-GE-PISA]] | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32P-10GE-PISA]] | ||
+ | |||
+ | *Supervisor Engine 720 | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/> | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/> | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]] <br/> | ||
+ | ** VS-S720-10G-3C | ||
+ | ** VS-S720-10G-3CXL | ||
<br/> | <br/> | ||
'''''Note:''''' Redundant supervisor engines must be configured identically. | '''''Note:''''' Redundant supervisor engines must be configured identically. | ||
<br/><br/> | <br/><br/> | ||
− | '''Supported supervisor engines in the | + | '''Supported supervisor engines in the Cisco WS-C6506-E switch''' |
<br> | <br> | ||
− | *Supervisor Engine 2 | + | *Supports Supervisor Engine 2 |
− | * | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-PFC2]]<br/> |
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-MSFC2]] <br/> | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2U-MSFC2]] <br/> | ||
+ | |||
*Supervisor Engine 32 | *Supervisor Engine 32 | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B ]] | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]] | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32-GE-PISA]] | ||
+ | **[[Cisco catalyst 6000 / 6500 series supervisor engines | WS-S32P-10GE-PISA]] | ||
+ | |||
*Supervisor Engine 720 | *Supervisor Engine 720 | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/> | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/> | ||
+ | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]] <br/> | ||
+ | ** VS-S720-10G-3C | ||
+ | ** VS-S720-10G-3CXL | ||
<br/> | <br/> | ||
'''''Note:''''' Redundant supervisor engines must be configured identically. | '''''Note:''''' Redundant supervisor engines must be configured identically. | ||
<br/><br/> | <br/><br/> | ||
− | ==Fan | + | |
− | '''Supported Fan | + | ==Fan trays == |
+ | '''Supported Fan trays in the WS-C6506 series''' | ||
<br/> | <br/> | ||
* Standard fan tray | * Standard fan tray | ||
Line 27: | Line 59: | ||
** WS-C6K-6SLOT-FAN2 | ** WS-C6K-6SLOT-FAN2 | ||
<br/> | <br/> | ||
− | '''Supported Fan trys in the | + | '''''Note''''' The standard fan tray will only support WS-X6K-S2-PFC2, WS-X6K-S2-MSFC2 and WS-X6K-S2U-MSFC2. Supervisor Engin 32 and 720 will need a high-speed fan tray |
+ | <br/><br/> | ||
+ | '''Supported Fan trys in the WS-C6506-E series''' | ||
<br/> | <br/> | ||
*one hot-swappable fan tray | *one hot-swappable fan tray | ||
− | **WS-C6506-E- | + | **WS-C6506-E-FAN |
<br/> | <br/> | ||
− | ==Power supplies | + | '''''Note:''''' The WS-C6506-E-Fan ist a high-speed fan tray. |
− | Both, the Cisco | + | |
+ | ==Power supplies== | ||
+ | Both, the Cisco WS-C6506 and the Cisco 6506-E switch have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.<br/> | ||
<br/> | <br/> | ||
− | '''Supported spower supplies in the Cisco | + | '''Supported spower supplies in the Cisco WS-C6506 switch''' |
<br/> | <br/> | ||
* 1000 W AC-input power supply | * 1000 W AC-input power supply | ||
Line 60: | Line 96: | ||
** WS-CAC-8700W | ** WS-CAC-8700W | ||
<br/> | <br/> | ||
− | '''Supported spower supplies in the Cisco | + | '''Supported spower supplies in the Cisco WS-C6506-E switch''' |
<br/> | <br/> | ||
* 2500 W AC-input power supply | * 2500 W AC-input power supply |
Latest revision as of 11:03, 15 July 2009
Both, The Cisco Catalyst 6506 switch and the Cisco Catalyst 6506-E switch have 6-slot horizontal slots and being nummbered from 1 (botton) to 6 (top).
Video Datasheet
Cisco Catalyst 6506-E Datasheet
Supervisor engines
Supported supervisor engines in the Cisco WS-C6506 switch
Note: Supervisor Engine 2 is installed in slot 1 or slot 2. Supervisor Engine 32 and Supervisor Engine 720 are installed in slot 5 or slot 6.
- Supports Supervisor Engine 2
- Supervisor Engine 32
- Supervisor Engine 720
- WS-SUP720
- WS-SUP720-3B
- WS-SUP720-3BXL
- VS-S720-10G-3C
- VS-S720-10G-3CXL
- WS-SUP720
Note: Redundant supervisor engines must be configured identically.
Supported supervisor engines in the Cisco WS-C6506-E switch
- Supports Supervisor Engine 2
- Supervisor Engine 32
- Supervisor Engine 720
- WS-SUP720
- WS-SUP720-3B
- WS-SUP720-3BXL
- VS-S720-10G-3C
- VS-S720-10G-3CXL
- WS-SUP720
Note: Redundant supervisor engines must be configured identically.
Fan trays
Supported Fan trays in the WS-C6506 series
- Standard fan tray
- WS-C6K-6SLOT-FAN
- High- Speed fan tray
- WS-C6K-6SLOT-FAN2
Note The standard fan tray will only support WS-X6K-S2-PFC2, WS-X6K-S2-MSFC2 and WS-X6K-S2U-MSFC2. Supervisor Engin 32 and 720 will need a high-speed fan tray
Supported Fan trys in the WS-C6506-E series
- one hot-swappable fan tray
- WS-C6506-E-FAN
Note: The WS-C6506-E-Fan ist a high-speed fan tray.
Power supplies
Both, the Cisco WS-C6506 and the Cisco 6506-E switch have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.
Supported spower supplies in the Cisco WS-C6506 switch
- 1000 W AC-input power supply
- WS-CAC-1000W
- 1300 W AC-input power supply
- WS-CAC-1300W
- 1300 W DC-input power supply
- WS-CDC-1300W
- 2500 W AC-input power supply
- WS-CAC-2500W
- 2500 W DC-input power supply
- WS-CDC-2500W
- 3000 W AC-input power supply
- WS-CAC-3000W
- 4000 W AC-input power supply
- WS-CAC-4000W-US
- 4000 W AC-input power supply
- WS-CAC-4000W-INT
- 4000 W DC-input power supply
- PWR-4000-DC
- 6000 W AC-input power supply
- WS-CAC-6000W
- 8700 W AC-input power supply
- WS-CAC-8700W
Supported spower supplies in the Cisco WS-C6506-E switch
- 2500 W AC-input power supply
- WS-CAC-2500W
- 2500 W DC-input power supply
- WS-CDC-2500W
- 3000 W AC-input power supply
- WS-CAC-3000W
- 4000 W AC-input power supply
- WS-CAC-4000W-US
- 4000 W AC-input power supply
- WS-CAC-4000W-INT
- 4000 W DC-input power supply
- PWR-4000-DC
- 6000 W AC-input power supply
- WS-CAC-6000W
- 8700 W AC-input power supply
- WS-CAC-8700W-E