Difference between revisions of "Gigabit Ethernet Transceiver Modules Compatibility Matrix"
From NesevoWiki
Jump to navigationJump to search(52 intermediate revisions by the same user not shown) | |||
Line 2,359: | Line 2,359: | ||
|| | || | ||
|| | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | == Catalyst 3700 Switches Support == | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM Support''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||Catalyst 3750-E Series | ||
+ | ||WS-C3750E-24TD | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.2(35)SE2 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750E-24PD | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750E-48TD | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750E-48PD | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(35)SE2 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750E-48PDF | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||With CVR-X2-SFP (for X2 ports) | ||
+ | ||GLC-ZX-SM <br/>GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(44)SE | ||
+ | ||12.2(40)SE | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(52)SE | ||
+ | ||12.2(52)SE | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | || | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM Support''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||Catalyst 3750 series | ||
+ | ||WS-C3750G-12S | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.1.(14)EA1 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750G-24TS | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750G-48TS | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750G-24PS | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(46)SE | ||
+ | ||12.1(14)EA1 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750G-48PS | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(25)SEB | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(40)SE | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(52)SE | ||
+ | ||12.2(52)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750-24TS | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.1(14)EA1 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750-48TS | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(46)SE | ||
+ | ||12.1(14)EA1 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | ||12.2(46)SE | ||
+ | ||12.1(19)EA1c | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(25)SEB | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(40)SE | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(52)SE | ||
+ | ||12.2(52)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750-24PS | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.1(19)EA1c | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750-48PS | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(46)SE | ||
+ | ||12.1(19)EA1c | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(25)SEB | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(40)SE | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(52)SE | ||
+ | ||12.2(52)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750-24FS-S | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.2(25)SEB | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(25)SEB | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(40)SE | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(52)SE | ||
+ | ||12.2(52)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750-24WFS | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||— | ||
+ | ||12.2(25)FZ | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(25)FZ | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(46)SE | ||
+ | ||12.2(40)SE | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(52)SE | ||
+ | ||12.2(52)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750V2-24PS | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.2(50)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750V2-24TS | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750V2-48PS | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750V2-48TS | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(50)SE | ||
+ | ||12.2(50)SE | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(52)SE | ||
+ | ||12.2(52)SE | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM Support''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||Catalyst 3750-X Series | ||
+ | ||WS-C3750X-24T | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.2(53)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-48T | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-24P | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-48P | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(53)SE | ||
+ | ||12.2(53)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-48PF | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||With C3KX-NM-1G and | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||C3KX-NM-10G (slots 1<br/>and 3) network modules | ||
+ | ||GLC-BX-D<br/>GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-24T | ||
+ | ||GLC-SX-MM | ||
+ | ||— | ||
+ | ||12.2(53)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-48T | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-24P | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(53)SE | ||
+ | ||12.2(53)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-48P | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-48PF | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||With C3KX-NM-10G | ||
+ | ||GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||(slots 2 and 4) and | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||C3KX-SM-10G network modules | ||
+ | ||CWDM SFP <br/>SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-12S | ||
+ | ||GLC-T (10/100/1000) | ||
+ | ||— | ||
+ | ||12.2(58)SE1 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-24S | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||Client ports and uplink | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||ports with C3KX-NM-1G and C3KX-NM-10G | ||
+ | ||GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||12.2(58)SE1 | ||
+ | ||12.2(58)SE1 | ||
+ | |- | ||
+ | || | ||
+ | ||(slots 1 and 3) network modules | ||
+ | ||GLC-ZX-SM <br/>GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-12S | ||
+ | ||GLC-SX-MM | ||
+ | ||— | ||
+ | ||12.2(58)SE1 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C3750X-24S | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||Uplink ports with | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(58)SE1 | ||
+ | ||12.2(58)SE1 | ||
+ | |- | ||
+ | || | ||
+ | ||C3KX-NM-10G (slots 2 and 4) and C3KX-SM-10G network modules | ||
+ | ||GLC-LH-SMD <br/>GLC-ZX-SM <br/>GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | == Industrial Ethernet and Smart Grid Support == | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''Catalyst Operating System''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||Cisco 2500 Connected Grid Switch Series | ||
+ | ||CGS-2520-24TC <br/>CGS-2520-16S-8PC | ||
+ | ||GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD GLC-BX-D<br/>GLC-BX-U<br/>SFP-GE-S<br/>SFP-GE-L<br/>GLC-EX-SMD<br/>SFP-GE-Z<br/>CWDM SFP | ||
+ | ||Not supported | ||
+ | ||12.2(53)EX | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''Catalyst Operating System''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||Cisco 2000 Connected Grid Router Series | ||
+ | ||CGR 2010 | ||
+ | ||GLC-SX-MM-RGD <br/>GLC-LX-SM-RGD <br/>GLC-ZX-SM-RGD | ||
+ | ||Not supported | ||
+ | ||15.1(1)T | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | == Catalyst 4500 and Catalyst 4900 Switches Support == | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''Cisco IOS Support''' | ||
+ | ||'''DOM Support''' | ||
+ | |- | ||
+ | ||Catalyst 4500 series | ||
+ | ||WS-X4013 | ||
+ | ||WS-G5483 <br/>WS-G5484 <br/>WS-G5486 <br/>WS-G5487 <br/>CDWM GBIC | ||
+ | ||Not supported | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4013+ | ||
+ | ||WS-G5483 | ||
+ | ||12.1(19)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5484 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CDWM GBIC | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM GBIC | ||
+ | || | ||
+ | ||12.1(19)EW | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4013+TS | ||
+ | ||GLC-SX-MM | ||
+ | ||12.2(20)EWA | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(20)EWA | ||
+ | ||12.2(20)EWA | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(37)SG | ||
+ | ||12.2(37)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(53)SG3 | ||
+ | ||12.2(53)SG3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4013+10GE | ||
+ | ||GLC-SX-MM | ||
+ | ||12.2(25)SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(25)SG | ||
+ | ||12.2(25)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(37)SG | ||
+ | ||12.2(37)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(53)SG3 | ||
+ | ||12.2(53)SG3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4014 | ||
+ | ||WS-G5483 | ||
+ | ||12.1(13)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4232-GB-RJ | ||
+ | ||WS-G5484 | ||
+ | ||12.1(8a)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4306-GB | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4412-2GB-T | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM GBIC | ||
+ | ||12.1(12c)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM GBIC | ||
+ | ||12.1(19)EW | ||
+ | ||12.2(19)EW | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4418-GB | ||
+ | ||WS-G5484<br/>WS-G5486<br/>WS-G5487<br/>CWDM GBIC | ||
+ | ||12.1(8a)EW<br/><br/><br/>12.1(12c)EW | ||
+ | ||—<br/>— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM GBIC | ||
+ | ||12.1(19)EW | ||
+ | ||12.2(19)EW | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4302-GB | ||
+ | ||WS-G5483 | ||
+ | ||12.1(19)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5484 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM GBIC | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM GBIC | ||
+ | ||12.1(19)EW | ||
+ | ||12.2(19)EW | ||
+ | |- | ||
+ | || | ||
+ | ||WS-4448-GB-SFP | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||12.2(20)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | ||12.2(20)EW | ||
+ | ||12.2(20)EW | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(20)EWA | ||
+ | ||12.2(20)EWA | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4506-GB-T | ||
+ | ||GLC-SX-MM | ||
+ | ||12.2(20)EWA | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(20)EWA | ||
+ | ||12.2(20)EWA | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4515 | ||
+ | ||WS-G5483 | ||
+ | ||12.1(13)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5484 | ||
+ | ||12.1(12c)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM GBIC | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM GBIC | ||
+ | ||12.1(19)EW | ||
+ | ||12.1(19)EW | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4516 | ||
+ | ||WS-G5483 | ||
+ | ||12.2(18)EW | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5484 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM GBIC | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM GBIC | ||
+ | ||12.2(18)EW | ||
+ | ||12.2(18)EW | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4516-10GE | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||12.2(25)EWA | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(25)EWA | ||
+ | ||12.2(25)EWA | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | ||12.2(37)SG | ||
+ | ||12.2(37)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(53)SG3 | ||
+ | ||12.2(53)SG3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X45-SUP6-E | ||
+ | ||GLC-T | ||
+ | ||12.2(40)SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4606-X2 | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||with CVR-X2-SFP Twin | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||Gig converter | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(40)SG | ||
+ | ||12.2(40)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(53)SG3 | ||
+ | ||12.2(53)SG3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-4624-SFP-E | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||12.2(44)SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(44)SG | ||
+ | ||12.2(44)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(53)SG3 | ||
+ | ||12.2(53)SG3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X45-SUP6L-E | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||12.2(52)SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||with CVR-X2-SFP Twin | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||Gig converter | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(52)SG | ||
+ | ||12.2(52)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(53)SG3 | ||
+ | ||12.2(53)SG3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4612-SFP-E | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||12.2(54)SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||12.2(54)SG | ||
+ | ||12.2(54)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4640-CSFP-E | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||15.0(2)SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||15.0(2)SG | ||
+ | ||15.0(2)SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-2BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X4712-SFP+E | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||3.1.0SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X45-SUP7-E | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||3.1.0SG | ||
+ | ||3.1.0SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X45-SUP7L-E | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||3.2.0XO | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | ||3.2.0XO | ||
+ | ||3.2.0XO | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''Cisco IOS Support''' | ||
+ | ||'''DOM Support''' | ||
+ | |- | ||
+ | ||Catalyst 4500-X Series | ||
+ | ||WS-C4500X-32SFP+ | ||
+ | ||GLC-T (1000BASE-T) | ||
+ | ||3.3.0SG | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C4500X-F-32SFP+ | ||
+ | ||GLC-SX-MM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||WS-C4500X-40X-ES | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||C4KX-NM-8SFP+ | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | ||3.3.0SG | ||
+ | ||3.3.0SG | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-EX-SMD | ||
+ | ||15.1(1)SG | ||
+ | ||15.1(1)SG | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ==Catalyst 6500 Switches Support == | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''Catalyst Operating System''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | ||'''DOM Support''' | ||
+ | |- | ||
+ | ||Catalyst 6500 Series<br/><br/><br/> | ||
+ | ||WS-X6K-SUP1-2GE <br/>WS-X6K-SUP1A-2GE <br/>WS-X6K-SUP1A-MSFC <br/>WS-X6K-SUP1A-MSFC2 <br/>WS-X6K-SUP1A-PFC <br/>WS-X6K-SUP2U-MSFC2 <br/>WS-X6K-S2-PFC2 | ||
+ | ||WS-G5483<br/>WS-G5484<br/>WS-G5486<br/>WS-G5487<br/>CWDM GBIC | ||
+ | ||7.2<br/>Please see release notes for details<br/>7.2 | ||
+ | ||12.1(13)E<br/>Please see<br/>release notes for details<br/>12.1(13)E | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X6K-SUP2-MSFC2 <br/>WS-X6K-SUP2U-PFC2 <br/>WS-X6408-GBIC <br/>WS-X6408A-GBIC <br/>WS-X6416-GBIC <br/>WS-X6516-GBIC <br/>WS-X6816-GBIC | ||
+ | ||WS-G5483<br/>WS-G5484<br/>WS-G5486<br/>WS-G5487<br/>CWDM GBIC<br/>DWDM GBIC | ||
+ | ||7.2<br/>Please see release notes for details<br/>7.2<br/>8.3.1 | ||
+ | ||12.1(13)E<br/>Please see<br/>release notes for details<br/>12.1(13)E <br/>12.2(17a)SX | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X6516A-GBIC | ||
+ | ||WS-G5483<br/>WS-G5484<br/>WS-G5486<br/>WS-G5487<br/>CWDM GBIC<br/>DWDM GBIC | ||
+ | ||7.5.1<br/>Please see release notes for details<br/>7.5.1<br/>8.3.1 | ||
+ | ||12.1(19)E1<br/>Please see<br/>release notes for details<br/>12.1(19)E1 <br/>12.2(17a)SX | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-SUP720 | ||
+ | ||GLC-T(1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U<br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||8.3.1 <br/>8.1.1 <br/>8.1.1 <br/>8.2<br/>8.4.1 <br/>8.4.1 <br/>8.3.1<br/>—<br/>—<br/>— | ||
+ | ||12.2(17a)SX <br/>12.2(14)SX <br/>12.2(17a)SX <br/>12.2(17d)SXB1 <br/>12.2(18)SXE1 <br/>12.2(18)SXE1 <br/>12.2(17a)SX <br/>12.2(33)SXH <br/>12.2(14)SX <br/>12.2(17a)SX | ||
+ | ||—<br/>—<br/>—<br/>— <br/>12.2(18)SXE1 <br/>12.2(18)SXE1 <br/>12.2(18)SXE <br/>12.2(33)SXH<br/>—<br/>— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-SUP720-3B <br/>WS-SUP720-3BXL | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U<br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||8.3.2 <br/>8.3.2 <br/>8.3.2 <br/>8.3.2 <br/>8.4.1 <br/>8.4.1 <br/>8.3.2<br/>—<br/>—<br/>— | ||
+ | ||12.2(17d)SXB1 <br/>12.2(17d)SXB1 <br/>12.2(17d)SXB1 <br/>12.2(17d)SXB1 <br/>12.2(18)SXE1 <br/>12.2(18)SXE1 <br/>12.2(17d)SXB1 <br/>12.2(33)SXH <br/>12.2(17d)SXB1 <br/>12.2(17d)SXB1 | ||
+ | ||—<br/>—<br/>—<br/>— <br/>12.2(18)SXE1 <br/>12.2(18)SXE1 <br/>12.2(18)SXE <br/>12.2(33)SXH<br/>—<br/>— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-SUP32-GE-3B <br/>WS-SUP32-10GE-3B | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U<br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||8.4(1) <br/>8.4(1) <br/>8.4(1) <br/>8.4(1) <br/>8.4(1) <br/>8.4(1) <br/>8.4(1)<br/>—<br/>—<br/>— | ||
+ | ||12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(33)SXH <br/>12.2(18)SXF <br/>12.2(18)SXF | ||
+ | ||—<br/>—<br/>—<br/>— <br/>12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(18)SXF <br/>12.2(33)SXH<br/>—<br/>— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-SUP32-GE-PISA | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U<br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.2(18)ZY | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||VS-S720-10G-3C <br/>VS-S720-10G-3CXL | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U<br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.2(33)SXH | ||
+ | ||—<br/>—<br/>—<br/>— <br/>12.2(33)SXH <br/>12.2(33)SXH <br/>12.2(33)SXH <br/>12.2(33)SXH<br/>—<br/>— | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X6724-SFP<br/>WS-X6748-SFP | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U<br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||8.3.1 <br/>8.1.1 <br/>8.1.1 <br/>8.2<br/>8.4.1 <br/>8.4.1 <br/>8.3.1<br/>—<br/>—<br/>— | ||
+ | ||12.2(17a)SX <br/>12.2(14)SX <br/>12.2(17a)SX <br/>12.2(17d)SXB1 <br/>12.2(18)SXE1 <br/>12.2(18)SXE1 <br/>12.2(17a)SX <br/>12.2(33)SXH<br/>12.2(14)SX <br/>12.2(17a)SX | ||
+ | ||— | ||
+ | |- | ||
+ | || | ||
+ | ||VS-S2T-10G<br/>VS-S2T-10G-XL <br/>WS-X6824-SFP-2T <br/>WS-X6824-SFP-2TXL <br/>WS-X6848-SFP-2T <br/>WS-X6848-SFP-2TXL | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM-SFP <br/>DWDM-SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.2(50)SY | ||
+ | ||— | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | == Data Center and Blade Switching Support == | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Catalyst 2350 Series | ||
+ | ||2350-48TD-S <br/>2350-48TD-SD<br/>(with CVR-X2-SFP TwinGig converter) | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-SX-MMD | ||
+ | ||— | ||
+ | ||Cisco IOS 12.2(46)EY | ||
+ | |- | ||
+ | ||Cisco Catalyst 2360 Series | ||
+ | ||2360-48TD-S | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD GLC-LH-SMD | ||
+ | ||— | ||
+ | ||Cisco IOS 12.2(53)EY | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Catalyst 3000 and 3100 Blade Switches | ||
+ | ||WS-CBS3020-HPQ | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||Cisco IOS 12.2(35)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-CBS3030-DEL <br/>WS-CBS3040-FSC | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-SX-MMD | ||
+ | ||— | ||
+ | ||Cisco IOS 12.2(35)SE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-CBS-3120G-S<br/>WS-CBS-3130G-S<br/>(with CVR-X2-SFP TwinGig converter) | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||Cisco IOS 12.2(40)EX1 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-CBS3032-DEL<br/>(with CVR-X2-SFP TwinGig converter) | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||Cisco IOS 12.2(40)EX1 | ||
+ | |- | ||
+ | || | ||
+ | ||WS-CBS3110X-S<br/>(with CVR-X2-SFP TwinGig converter) | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||Cisco IOS 12.2(52)SE | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Nexus 2000 Series | ||
+ | ||N2K-C2232PP-10GE | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||NX-OS 4.2(1)N2(1) | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Nexus 3000 Series | ||
+ | ||N3K-C3064PQ | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||NX-OS 5.0(3)U1(1d) | ||
+ | |- | ||
+ | || | ||
+ | ||N3K-C3064PQ-10GE | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||NX-OS 5.0(3)U1(2) | ||
+ | |- | ||
+ | || | ||
+ | ||N3K-C3048TP-1GE | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||NX-OS 5.0(3)U2(2b) | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Nexus 4000 Series | ||
+ | ||N4K-4001I-XPX | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||NX-OS 4.1(2)E1(1) | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Nexus 5000 Series | ||
+ | ||N5K-C5010P-BF<br/>N5K-C5020P-BF | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM<br/>SFP-GE-T (1000BASE-T)<br/>SFP-GE-S<br/>SFP-GE-L <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||—<br/><br/><br/><br/><br/><br/>NX-OS 4.0(1a)N1(1) | ||
+ | ||NX-OS 4.0(1a)N1(1)<br/>NX-OS 4.0(1a)N1(1) | ||
+ | |- | ||
+ | || | ||
+ | ||N5K-C5548P-FA <br/>N5K-C5548UP-FA <br/>N5KC5596UP-FA<br/>N55-M16P<br/>N55-M8P8FP <br/>N55-M16UP | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM<br/>SFP-GE-T (1000BASE-T)<br/>SFP-GE-S<br/>SFP-GE-L <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||—<br/><br/><br/><br/><br/><br/>NX-OS 5.0(3)N1(1B) | ||
+ | ||NX-OS 5.0(3)N1(1B)<br/>NX-OS 5.0(3)N1(1B) | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Unified Computing System | ||
+ | ||N10-S6100 <br/>N10-S6200 <br/>N10-E0440 <br/>N10-E0600 <br/>N20-I6584 | ||
+ | ||SFP-GE-S<br/>SFP-GE-L <br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>GLC-SX-MM <br/>GLC-LH-SM<br/>GLC-T (1000BASE-T) <br/>SFP-GE-T<br/>(1000BASE-T) | ||
+ | ||UCS Manager v1.3<br/><br/><br/><br/><br/>— | ||
+ | |align="center"|UCS Manager v1.3<br/>UCS Manager v1.3 | ||
+ | |- | ||
+ | || | ||
+ | ||UCS-FI-6248UP <br/>UCS-FI-E16UP <br/>UCS-IOM-2208XP | ||
+ | ||SFP-GE-S<br/>SFP-GE-L <br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>GLC-SX-MM <br/>GLC-LH-SM<br/>GLC-T (1000BASE-T) <br/>SFP-GE-T (1000BASE-T) | ||
+ | ||UCS Manager v2.0(1)<br/><br/><br/><br/><br/>— | ||
+ | |align="center"|UCS Manager v2.0(1)<br/>UCS Manager v2.0(1) | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco Nexus 7000 Series<br/> | ||
+ | ||N7K-F248XP-25 | ||
+ | ||GLC-T (1000BASE-T) <br/>SFP-GE-T (1000BASE-T)<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM<br/>GLC-SX-MMD <br/>SFP-GE-S <br/>GLC-LH-SMD <br/>SFP-GE-L <br/>SFP-GE-Z <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP | ||
+ | ||—<br/><br/><br/><br/><br/><br/><br/><br/>NX-OS 6.0 | ||
+ | ||NX-OS 6.0<br/>NX-OS 6.0 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco CSS 11500 Series | ||
+ | ||CSS11506-2AC <br/>CSS11506-2DC <br/>CSS11503-AC <br/>CSS11503-DC <br/>CSS11501 <br/>CSS5-SCM-2GE <br/>CSS5-IOM-2GE | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM | ||
+ | ||— | ||
+ | ||WebNS 7.5 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco MDS 9000 Series | ||
+ | ||Please refer to:<br/>http://www/en/US/prod/collateral/ps4159/ps6409/ps4358/product_data_sheet09186a00801bc698.html | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 892F Series | ||
+ | ||CISCO892F-K9 <br/>CISCO892FW-K9 | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||Not supported | ||
+ | ||15.1(2)T | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 2900 Series Router | ||
+ | ||Cisco 2921<br/>Cisco 2951 | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-U <br/>GLC-BX-D <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M | ||
+ | |- | ||
+ | || | ||
+ | ||HWIC-1GE-SFP | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M | ||
+ | |- | ||
+ | || | ||
+ | ||SM-D-ES3G-48-P <br/>SM-D-ES3-48-P <br/>SM-D-ES2-48 | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-U <br/>GLC-BX-D <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M | ||
+ | |- | ||
+ | || | ||
+ | ||EHWIC-1GE-SFP-CU | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.1(4)M | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ==Router Support == | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 1921 Series Router | ||
+ | ||HWIC-1GE-SFP | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M2 | ||
+ | |- | ||
+ | || | ||
+ | ||EHWIC-1GE-SFP-CU | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.1(4)M | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco1941 Series Router | ||
+ | ||HWIC-1GE-SFP | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M | ||
+ | |- | ||
+ | || | ||
+ | ||EHWIC-1GE-SFP-CU | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.1(4)M | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 2600 Series Router | ||
+ | ||NM-1GE | ||
+ | ||WS-G5483 <br/>WS-G5484 <br/>WS-G5486 <br/>WS-G5487 <br/>CWDM GBIC | ||
+ | ||— | ||
+ | ||12.2(11)YT | ||
+ | |- | ||
+ | || | ||
+ | ||NME-XD-24ES-1S-P<br/>NME-XD-48ES-2S-P | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.2(25)EZ | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 2800 Series Router | ||
+ | ||NME-XD-24ES-1S-P<br/>NME-XD-48ES-2S-P | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.2(25)EZ | ||
+ | |- | ||
+ | || | ||
+ | ||HWIC-1GE-SFP | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.3(8)T4 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 3200 Series Rugged Routers | ||
+ | ||Cisco 3270 | ||
+ | ||GLC-SX-MM-RGD <br/>GLC-LX-SM-RGD | ||
+ | ||— | ||
+ | |align="right"|12.4(6)XE | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 3600 Series Router | ||
+ | ||NM-1GE | ||
+ | ||WS-G5483 <br/>WS-G5484 <br/>WS-G5486 <br/>WS-G5487 <br/>CWDM GBIC | ||
+ | ||— | ||
+ | |align="right"|12.2(11)YT | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 3700 Series Router | ||
+ | ||NM-1GE | ||
+ | ||WS-G5483 <br/>WS-G5484 <br/>WS-G5486 <br/>WS-G5487 <br/>CWDM GBIC | ||
+ | ||— | ||
+ | |align="right"|12.2(11)YT | ||
+ | |- | ||
+ | || | ||
+ | ||NME-XD-24ES-1S-P<br/>NME-XD-48ES-2S-P | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | |align="right"|12.2(25)EZ | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 3800 Series Router | ||
+ | ||NM-1GE | ||
+ | ||WS-G5483 <br/>WS-G5484<br/>WS-G5486 <br/>WS-G5487 <br/>CWDM GBIC | ||
+ | ||— | ||
+ | ||12.2(11)YT | ||
+ | |- | ||
+ | || | ||
+ | ||NME-XD-24ES-1S-P<br/>NME-XD-48ES-2S-P | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.2(25)EZ | ||
+ | |- | ||
+ | || | ||
+ | ||HWIC-1GE-SFP | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.3(8)T4 | ||
+ | |- | ||
+ | || | ||
+ | ||Cisco 3825 | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.3(11)T | ||
+ | |- | ||
+ | || | ||
+ | ||Cisco 3845 | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.3(11)T | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 3900 Series Router | ||
+ | ||Cisco 3925<br/>Cisco 3945 | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-U <br/>GLC-BX-D <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M | ||
+ | |- | ||
+ | || | ||
+ | ||HWIC-1GE-SFP | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M | ||
+ | |- | ||
+ | || | ||
+ | ||SM-D-ES3G-48-P <br/>SM-D-ES3-48-P <br/>SM-D-ES2-48 | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-U <br/>GLC-BX-D <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.0(1)M | ||
+ | |- | ||
+ | || | ||
+ | ||EHWIC-1GE-SFP-CU | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||15.1(4)M | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 6400 Universal Access Router | ||
+ | ||C6400-NRP-2SV | ||
+ | ||WS-G5484<br/>WS-G5486<br/>WS-G5487 | ||
+ | ||— | ||
+ | ||12.2(2)B6 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 7200 Series Router | ||
+ | ||NPE-G1 | ||
+ | ||WS-G5484 | ||
+ | ||— | ||
+ | ||12.0(28)S | ||
+ | |- | ||
+ | ||The Cisco 7200 series | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | ||12.1(14)E | ||
+ | |- | ||
+ | ||router supports multiple | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | ||12.2(15)B | ||
+ | |- | ||
+ | ||parallel release | ||
+ | || | ||
+ | ||CWDM GBIC | ||
+ | || | ||
+ | ||12.2(4)BW | ||
+ | |- | ||
+ | ||branches. Where several | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||12.2(14)S | ||
+ | |- | ||
+ | ||releases are grouped | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||12.2(14)SU | ||
+ | |- | ||
+ | ||together, they provide | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||12.2(15)T9 | ||
+ | |- | ||
+ | ||support for all transcievers in the | ||
+ | ||Cisco 7201 | ||
+ | ||GLC-SX-MM | ||
+ | ||— | ||
+ | ||12.2(33)SRC2 | ||
+ | |- | ||
+ | ||corresponding group. | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | ||12.4(15)T7 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||12.4(20)T1 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-T | ||
+ | ||— | ||
+ | ||12.2(33)SRC2 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||12.4(15)T7 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | ||— | ||
+ | ||12.2(31)SB2 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | ||12.2(33)SRC2 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | ||12.4(15)T7 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||NPE-G2 | ||
+ | ||GLC-SX-MM | ||
+ | ||— | ||
+ | ||12.2(33)SRC2 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | ||12.4(15)T7 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||12.4(20)T1 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | ||— | ||
+ | ||12.2(31)SB2 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | ||12.2(33)SRC2 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | ||12.4(15)T7 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||C7200-I/O-GE+E | ||
+ | ||WS-G5484 | ||
+ | ||— | ||
+ | ||12.0(14)S2 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | ||12.1(3a)E5 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | ||12.1(5)T1 | ||
+ | |- | ||
+ | || | ||
+ | ||PA-GE | ||
+ | ||WS-G5484 | ||
+ | ||— | ||
+ | ||12.0(7)S | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | ||12.0(6)T | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | ||12.1(1)E | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco uBR7200 Series | ||
+ | ||uBR7200-NPE-G1 | ||
+ | ||WS-G5484 | ||
+ | ||— | ||
+ | |align="right"|12.2(11)CX | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM GBIC | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||uBR7200-NPE-G2 | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2SB | ||
+ | |align="right"|12.2SB | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 7300 Series Router | ||
+ | ||CISCO7301 | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||12.2(18)S1 | ||
+ | |- | ||
+ | || | ||
+ | ||7300-NSE-100 | ||
+ | ||WS-G5484<br/>WS-G5486<br/>WS-G5487<br/>WS-G5483 <br/>CWDM GBIC | ||
+ | ||— | ||
+ | ||12.2(20)S<br/><br/><br/>12.2(28)SB | ||
+ | |- | ||
+ | || | ||
+ | ||7304-NPE-G100 | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>CWDM SFP | ||
+ | ||— | ||
+ | ||12.2(20)S | ||
+ | |- | ||
+ | || | ||
+ | ||7300-NSE-150 | ||
+ | ||GLC-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM<br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>GLC-BX-D <br/>GLC-BX-U <br/>SFP-GE-S <br/>SFP-GE-L <br/>SFP-GE-Z <br/>CWDM SFP | ||
+ | ||—<br/><br/><br/><br/><br/>12.2(31)SB2 | ||
+ | ||12.2(31)SB2<br/>12.2(31)SB2 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 7500 Series Router | ||
+ | ||GEIP | ||
+ | ||WS-G5484<br/>WS-G5486<br/>WS-G5487 | ||
+ | ||— | ||
+ | ||Please see release notes | ||
+ | |- | ||
+ | || | ||
+ | ||GEIP+ | ||
+ | ||WS-G5484<br/>WS-G5486<br/>WS-G5487 | ||
+ | ||— | ||
+ | ||Please see release notes | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 7600 Series Router | ||
+ | ||OSM-1CHOC12/T1-SI <br/>OSM-1CHOC12/T3-SI <br/>OSM-2OC12-ATM-MM <br/>OSM-2OC12-ATM-SI<br/>OSM-2OC12-ATM-MM+ <br/>OSM-2OC12-ATM-SI+ <br/>OSM-4OC3-POS-SI <br/>OSM-4OC3-POS-SI+ <br/>OSM-4OC12-POS-SI <br/>OSM-4OC12-POS-SI+ <br/>OSM-8OC3-POS-MM <br/>OSM-8OC3-POS-SI <br/>OSM-8OC3-POS-SL <br/>OSM-8OC3-POS-SL+ <br/>OSM-8OC3-POS-SI+ <br/>OSM-16OC3-POS-MM <br/>OSM-16OC3-POS-SI <br/>OSM-16OC3-POS-SL <br/>OSM-16OC3-POS-SI+<br/>OSM-2OC12-POS-MM <br/>OSM-2OC12-POS-SI <br/>OSM-2OC12-POS-SL <br/>OSM-2OC12-POS-SI+ <br/>OSM-2OC12-POS-MM+ <br/>OSM4OC12-POS-MM <br/>OSM4OC12-POS-SI <br/>OSM4OC12-POS-SL <br/>OSM4OC12-POS-SI+ <br/>OSM-1OC48-POS-SI <br/>OSM-1OC48-POS-SL <br/>OSM-1OC48-POS-SS <br/>OSM-1OC48-POS-SS+ <br/>OSM-10C48-POS-SI+ <br/>OSM-1OC48-POS-SL+ <br/>OSM-2OC48/1DPT-SS <br/>OSM-2OC48/1DPT-SI <br/>OSM-2OC48/1DPT-SL <br/>OSM-2+4GE-WAN+ <br/>OSM-4GE-WAN-GBIC | ||
+ | ||WS-G5484 <br/>WS-G5486 <br/>WS-G5487 <br/>CWDM GBIC | ||
+ | ||— | ||
+ | ||Please see release notes | ||
+ | |- | ||
+ | || | ||
+ | ||WS-SUP720 <br/>WS-SUP720-3B <br/>WS-SUP720-3BXL | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>CWDM SFP | ||
+ | ||—<br/><br/><br/><br/><br/><br/><br/>12.2(33)SRA | ||
+ | ||12.2(33)SRA<br/>12.2(33)SRA | ||
+ | |- | ||
+ | || | ||
+ | ||WS-SUP32-GE-3B | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>GLC-BX-D<br/>GLC-BX-U<br/>CWDM SFP<br/>DWDM SFP | ||
+ | ||—<br/><br/><br/><br/><br/><br/><br/><br/>12.2(33)SRA<br/><br/>12.2(33)SRB<br/>12.2(33)SRE | ||
+ | ||12.2(33)SRA<br/>12.2(33)SRA<br/><br/>12.2(33)SRB<br/>12.2(33)SRE | ||
+ | |- | ||
+ | || | ||
+ | ||WS-X6724-SFP<br/>WS-X6748-SFP | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-BX-D <br/>GLC-BX-U<br/>CWDM SFP <br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>SFP-GE-T (1000BASE-T) <br/>SFP-GE-S<br/>SFP-GE-L <br/>SFP-GE-Z<br/>DWDM SFP | ||
+ | ||—<br/><br/><br/><br/><br/><br/><br/>—<br/>— | ||
+ | ||12.2(33)SRA<br/><br/><br/><br/><br/><br/><br/>12.2(33)SRB<br/>12.2(33)SRE | ||
+ | |- | ||
+ | || | ||
+ | ||RSP720-3C-GE <br/>RSP720-3CXL-GE | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM<br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>SFP-GE-T (1000BASE-T)<br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP <br/>SFP-GE-S<br/>SFP-GE-L | ||
+ | ||—<br/><br/><br/><br/>12.2(33)SRE1<br/><br/>— <br/>12.2(33)SRE1 | ||
+ | ||12.2(33)SRB<br/><br/><br/><br/>12.2(33)SRB<br/><br/>12.2(33)SRE1<br/>12.2(33)SRE1 | ||
+ | |- | ||
+ | || | ||
+ | ||RSP720-10GE | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM<br/>SFP-GE-T (1000BASE-T)<br/>GLC-BX-D <br/>GLC-BX-U <br/>SFP-GE-S <br/>SFP-GE-L <br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>CWDM SFP<br/>DWDM SFP | ||
+ | ||—<br/><br/><br/><br/><br/><br/>12.2(33)SRC<br/><br/><br/><br/><br/><br/><br/>12.2(33)SRE1 | ||
+ | ||12.2(33)SRC<br/>12.2(33)SRC<br/><br/><br/><br/><br/>12.2(33)SRE1 | ||
+ | |- | ||
+ | || | ||
+ | ||7600-ES20-GE3CXL <br/>7600-ES20-GE3C | ||
+ | ||SFP-GE-S <br/>SFP-GE-L <br/>SFP-GE-Z <br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>SFP-GE-T <br/>CWDM SFP<br/>GLC-BX-D <br/>GLC-BX-U <br/>DWDM SFP<br/>DWDM SFP (add.) | ||
+ | ||12.2(33)SRB<br/><br/><br/><br/>— 12.2(33)SRB3<br/>12.2(33)SRD<br/>12.2(33)SRE | ||
+ | ||12.2(33)SRB<br/><br/><br/><br/>12.2(33)SRB3 12.2(33)SRD<br/><br/><br/>12.2(33)SRE | ||
+ | |- | ||
+ | || | ||
+ | ||7600-ES+20G3C <br/>7600-ES+20G3CXL <br/>7600-ES+40G3C <br/>7600-ES+40G3CXL | ||
+ | ||SFP-GE-T<br/>GLC-SX-MMD <br/>GLC-LH-SMD <br/>SFP-GE-S<br/>SFP-GE-L <br/>SFP-GE-Z <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP<br/>DWDM SFP (add.) | ||
+ | ||— 12.2(33)SRD<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>12.2(33)SRE | ||
+ | ||12.2(33)SRD<br/>12.2(33)SRD<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>12.2(33)SRE | ||
+ | |- | ||
+ | || | ||
+ | ||76-ES+T-20G | ||
+ | ||SFP-GE-T | ||
+ | ||— | ||
+ | ||12.2(33)SRD3 | ||
+ | |- | ||
+ | || | ||
+ | ||76-ES+T-40G | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(33)SRD3 | ||
+ | ||12.2(33)SRD3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | ||12.2(33)SRE | ||
+ | ||12.2(33)SRE | ||
+ | |- | ||
+ | || | ||
+ | ||76-ES+XC-20G3C | ||
+ | ||SFP-GE-T | ||
+ | ||— | ||
+ | ||12.2(33)SRE | ||
+ | |- | ||
+ | || | ||
+ | ||76-ES+XC-20G3CXL | ||
+ | ||GLC-SX-MMD | ||
+ | ||12.2(33)SRE | ||
+ | ||12.2(33)SRE | ||
+ | |- | ||
+ | || | ||
+ | ||76-ES+XC-40G3C | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||76-ES+XC-40G3CXL | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-D | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-BX-U | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP (add.) | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 10000 Series Router | ||
+ | ||ESR-1GE | ||
+ | ||WS-G5484 | ||
+ | ||— | ||
+ | ||Please see release | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | ||notes | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||ESR-HH-1GE | ||
+ | ||SFP-GE-T | ||
+ | ||— | ||
+ | ||12.0(23)S | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | ||12.0(23)S | ||
+ | ||12.0(23)S | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco RF Gateway Series | ||
+ | ||RFGW-X4516-10GE | ||
+ | ||SFP-GE-S | ||
+ | ||12.2(44)SQ | ||
+ | ||12.2(44)SQ | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||RFGW-DS48 | ||
+ | ||SFP-GE-T | ||
+ | ||— | ||
+ | ||12.2(44)SQ | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-S | ||
+ | ||12.2(44)SQ | ||
+ | ||12.2(44)SQ | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 10700 Series Internet Router | ||
+ | ||10720-GE-FE-TX | ||
+ | ||SFP-GE-T | ||
+ | ||— | ||
+ | ||12.0(27)S | ||
+ | |- | ||
+ | || | ||
+ | ||10720-GE-FE-TX-B | ||
+ | ||SFP-GE-S | ||
+ | ||12.0(26)S | ||
+ | ||12.0(26)S | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | ||12.0(31)S | ||
+ | ||12.0(31)S | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco 12000 Series Router | ||
+ | ||3GE-GBIC-SC | ||
+ | ||WS-G5484 | ||
+ | ||— | ||
+ | |align="right"|12.0(11)S3 | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5486 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||WS-G5487 | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM GBIC | ||
+ | || | ||
+ | |align="right"|12.0(32)S | ||
+ | |- | ||
+ | || | ||
+ | ||10x1GE-SFP-LC-B | ||
+ | ||GLC-SX-MM | ||
+ | ||— | ||
+ | |align="right"|12.0(21)S | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||4GE-SFP-LC | ||
+ | ||GLC-SX-MM | ||
+ | ||— | ||
+ | |align="right"|12.0(25)S | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | |align="right"|12.0(32)S | ||
+ | |- | ||
+ | || | ||
+ | ||EPA-3GE-SX/LH-LC | ||
+ | ||GLC-SX-MM | ||
+ | ||— | ||
+ | |align="right"|12.0(23)S | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-ZX-SM | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Shared Port Adapters (SPAs) | ||
+ | ||SPA-2X1GE | ||
+ | ||SFP-GE-T | ||
+ | ||SPA software support is determined by | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-5X1GE | ||
+ | ||SFP-GE-S | ||
+ | ||the platform on which the SPA is | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-8X1GE | ||
+ | ||SFP-GE-L | ||
+ | ||installed. Refer to the SPA release notes | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-10X1GE | ||
+ | ||SFP-GE-Z | ||
+ | ||for the correct software release. | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-5X1GE-V2 | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-8X1GE-V2 | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-10X1GE-V2 | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-2GE-7304 | ||
+ | ||SFP-GE-S | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | ||SPA-2X1GE-V2 | ||
+ | ||SFP-GE-L | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||SFP-GE-Z | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||CWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||DWDM SFP | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-SX-MMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | ||GLC-LH-SMD | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||CRS Router Series | ||
+ | ||CRS-16-RP | ||
+ | ||GLC-LH-SM <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||XR 2.0 | ||
+ | |- | ||
+ | || | ||
+ | ||CRS-16-RP-B | ||
+ | ||GLC-LH-SM <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||XR 3.3 | ||
+ | |- | ||
+ | || | ||
+ | ||CRS-FCC-SC-22GE | ||
+ | ||GLC-LH-SM <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||XR 3.4.1 | ||
+ | |- | ||
+ | || | ||
+ | ||42-1GE 20-1GE-FLEX | ||
+ | ||SFP-GE-T (1000BASE-T)<br/>SFP-GE-S <br/>GLC-SX-MMD<br/>SFP-GE-L <br/>GLC-LH-SMD<br/>SFP-GE-Z | ||
+ | ||—<br/>XR 3.8.1 | ||
+ | ||XR 3.8.1<br/>XR 3.8.1 | ||
+ | |- | ||
+ | || | ||
+ | ||CRS-8-PRP-6G <br/>CRS-8-PRP-12G | ||
+ | ||GLC-LH-SM <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||XR 4.0.2 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||ASR 901 Series Router | ||
+ | ||A901-12C-F-D <br/>A901-12-C-FT-D | ||
+ | ||GLC-T<br/>SFP-GE-T<br/>GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-ZX-SM <br/>GLC-SX-MM-RGD <br/>GLC-LX-SM-RGD<br/>SFP-GE-S<br/>SFP-GE-L<br/>SFP-GE-Z | ||
+ | ||—<br/><br/><br/><br/><br/><br/><br/><br/><br/>15.1(2)SNG | ||
+ | |align="center"|15.1(2)SNG<br/>15.1(2)SNG | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco ASR 903 Series | ||
+ | ||A900-IMA8S | ||
+ | ||SFP-GE-T <br/>GLC-SX-MM-RGD <br/>GLC-LX-SM-RGD <br/>GLC-ZX-SM-RGD<br/>GLC-BX-D <br/>GLC-BX-U <br/>GLC-EX-SMD<br/>GLC-SX-MMD <br/>GLC-LH-SMD<br/>CWDM SFP <br/>DWDM SFP <br/>DWDM SFP (add.) | ||
+ | ||—<br/><br/><br/><br/><br/>XE 3.5.0S<br/>XE 3.6.0S | ||
+ | ||XE 3.5.0S<br/><br/><br/><br/><br/>XE 3.5.0S<br/>XE 3.6.0S | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||ASR 1000 Series Router | ||
+ | ||ASR1001 <br/>ASR1002 <br/>ASR1002-F | ||
+ | ||SFP-GE-T<br/>SFP-GE-S<br/>SFP-GE-L <br/>SFP-GE-Z <br/>CWDM SFP <br/>DWDM SFP<br/>GLC-BX-D<br/>GLC-BX-U<br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||—<br/>XE 2.1<br/><br/><br/><br/><br/><br/>XE 2.5 XE 3.4S | ||
+ | ||XE 2.1<br/>XE 2.1<br/><br/><br/><br/><br/>XE 2.5 XE 3.4S | ||
+ | |- | ||
+ | || | ||
+ | ||ASR 1000 platform with SPA cards | ||
+ | ||Software support on the ASR 1000 modular platforms is determined by the platform on which the SPA is installed. Refer to the SPA release notes for the correct software release.<br/>http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_ad apters/configuration/ASR1000/ASRspasw.pdf | ||
+ | || | ||
+ | || | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||ASR 9000 Series Router | ||
+ | ||A9K-40GE-B<br/>A9K-40GE-E | ||
+ | ||SFP-GE-T (10/100/1000)<br/>SFP-GE-S<br/>SFP-GE-L <br/>SFP-GE-Z <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP<br/>DWDM SFP (add.)<br/>GLC-SX-MMD <br/>GLC-LH-SMD <br/>GLC-EX-SMD | ||
+ | ||—<br/>XR 3.7.3<br/><br/><br/><br/><br/><br/><br/><br/>XR 3.9.0<br/>XR 4.1.1 | ||
+ | ||XR 3.7.3<br/>XR 3.7.3<br/><br/><br/><br/><br/><br/><br/><br/>XR 3.9.0<br/>XR 4.1.1 | ||
+ | |- | ||
+ | || | ||
+ | ||A9K-2T20GE-B <br/>A9K-2T20GE-E <br/>A9K-2T20GE-L <br/>A9K-40GE-L | ||
+ | ||SFP-GE-T (10/100/1000)<br/>SFP-GE-S<br/>SFP-GE-L <br/>SFP-GE-Z <br/>GLC-BX-D <br/>GLC-BX-U <br/>CWDM SFP <br/>DWDM SFP <br/>DWDM SFP (add.)<br/>GLC-SX-MMD <br/>GLC-LH-SMD <br/>GLC-EX-SMD | ||
+ | ||—<br/>XR 3.9.0<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>XR 4.1.1 | ||
+ | ||XR 3.9.0<br/>XR 3.9.0<br/><br/><br/><br/><br/><br/><br/><br/><br/>XR 4.1.1 | ||
+ | |- | ||
+ | || | ||
+ | ||A9K-MPA-20X1GE | ||
+ | ||SFP-GE-T (10/100/1000)<br/>SFP-GE-S<br/>SFP-GE-L<br/>SFP-GE-Z<br/>GLC-BX-D<br/>GLC-BX-U<br/>CWDM SFP<br/>DWDM SFP<br/>DWDM SFP (add.) <br/>GLC-SX-MMD <br/>GLC-LH-SMD <br/>GLC-EX-SMD | ||
+ | ||—<br/>XR 4.2.0 | ||
+ | ||XR 4.2.0<br/>XR 4.2.0 | ||
+ | |- | ||
+ | || | ||
+ | ||A9K-RSP440-TR <br/>A9K-RSP440-SE <br/>ASR-9001 | ||
+ | ||SFP-GE-T (10/100/1000)<br/>SFP-GE-S<br/>SFP-GE-L<br/>SFP-GE-Z<br/>GLC-BX-D<br/>GLC-BX-U<br/>CWDM SFP<br/>DWDM SFP<br/>DWDM SFP (add.) <br/>GLC-SX-MMD <br/>GLC-LH-SMD <br/>GLC-EX-SMD | ||
+ | ||—<br/>XR 4.2.1 | ||
+ | ||XR 4.2.1<br/>XR 4.2.1 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM support''' | ||
+ | ||'''Cisco IOS or NX-OS Release''' | ||
+ | |- | ||
+ | ||Cisco MWR 2941<br/>Mobile Wireless Routers | ||
+ | ||MWR-2941-DC | ||
+ | ||GLC-SX-MMD <br/>GLC-LH-SMD<br/>SFP-GE-S<br/>SFP-GE-L<br/>SFP-GE-Z<br/>GLC-SX-MM-RGD <br/>GLC-LX-SM-RGD <br/>GLC-ZX-SM-RGD<br/>SFP-GE-T<br/><br/>CWDM SFP<br/>DWDM SFP<br/>GLC-BX-D<br/>GLC-BX-U<br/>GLC-EX-SMD | ||
+ | ||12.4(19)MR1<br/><br/><br/><br/>—<br/>—<br/><br/>12.4(19MR3/ <br/>12.2(33)MRA<br/>12.2(33)MRB/<br/>12.4(20)MRA<br/>15.1(01)MR | ||
+ | ||12.4(19)MR1<br/>12.4(19)MR1<br/><br/>12.4(19)MR3/<br/>12.2(33)MRA<br/>12.4(19MR3/ <br/>12.2(33)MRA<br/>12.2(33)MRB/ <br/>12.4(20)MRA<br/>15.1(01)MR | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | == Appliance Support == | ||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM Support''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||ASA5500 Series appliances | ||
+ | ||SSM-4GE | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | ||ASA 7.0 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM Support''' | ||
+ | ||'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||NAM 2200 Series appliances | ||
+ | ||NAM2204-SFP | ||
+ | ||GLC-T (1000BASE-T) <br/>GLC-SX-MM<br/>GLC-LH-SM | ||
+ | ||— | ||
+ | ||NAM 4.0 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | {| border = "1" | ||
+ | ||'''Platform''' | ||
+ | ||'''Switch or Module''' | ||
+ | ||'''Transceiver Module''' | ||
+ | ||'''Minimum Software Release Required''' | ||
+ | || | ||
+ | |- | ||
+ | || | ||
+ | || | ||
+ | || | ||
+ | ||'''DOM Support''' | ||
+ | |align="right"|'''Cisco IOS Release''' | ||
+ | |- | ||
+ | ||Catalyst Express 500 | ||
+ | ||WS-CE500-24LC <br/>WS-CE500-24PC <br/>WS-CE500G-12TC | ||
+ | ||GLC-SX-MM <br/>GLC-LH-SM <br/>GLC-SX-MMD <br/>GLC-LH-SMD | ||
+ | ||— | ||
+ | |align="right"|12.2(25)FY | ||
|- | |- | ||
|} | |} |
Latest revision as of 11:09, 14 September 2012
Catalyst Express 500 Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst Express 500 | WS-CE500-24LC WS-CE500-24PC WS-CE500G-12TC |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)FY |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst Express 520 | WS-CE520-8PC-K9 | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(35)EX |
WS-CE520-24LC-K9 WS-CE520-24PC-K9 WS-CE520G-24TC-K9 |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(37)EX |
Metro Ethernet Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | ||
DOM Support | Cisco IOS Release | ||||
Cisco ME 2400 | ME-2400-24TS-A | GLC-T(10/100/1000) | — | 12.2(25)EX | |
ME-2400-24TS-D | GLC-SX-MM | ||||
GLC-LH-SM | |||||
GLC-ZX-SM | |||||
GLC-BX-D | 12.2(44)SE | 12.2(25)EX | |||
GLC-BX-U | |||||
CDWM SFP |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Cisco ME 3400 | ME-3400-24TS-A | GLC-T (10/100/1000) | — | 12.2(25)EX |
ME-3400-24TS-D | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)EX | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(25)EX | ||
GLC-BX-D | 12.2(44)SE | 12.2(25)EX | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400G-12CS-A | GLC-T (10/100/1000) | — | 12.2(25)SEG1 | |
ME-3400G-12CS-D | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)SEG1 | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(25)SEG1 | ||
GLC-BX-D | 12.2(44)SE | |||
GLC-BX-U | 12.2(44)SE | |||
CWDM SFP | 12.2(44)SE | 12.2(25)SEG1 | ||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400G-2CS-A | GLC-T (10/100/1000) | — | 12.2(35)SE1 | |
GLC-SX-MM | — | |||
GLC-LH-SM | — | |||
GLC-SX-MMD | 12.2(46)SE | 12.2(35)SE1 | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(35)SE1 | ||
GLC-BX-D | 12.2(44)SE | |||
GLC-BX-U | 12.2(44)SE | |||
CWDM SFP | 12.2(44)SE | 12.2(35)SE1 | ||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400-24FS-A | GLC-T (10/100/1000) | — | 12.2(40)SE | |
GLC-SX-MM | — | |||
GLC-LH-SM | — | |||
GLC-ZX-SM | 12.2(46)SE | |||
GLC-SX-MMD | 12.2(46)SE | |||
GLC-LH-SMD | 12.2(46)SE | |||
GLC-BX-D | 12.2(44)SE | 12.2(40)SE | ||
GLC-BX-U | ||||
CWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP | 12.2(50)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
SFP-GE-L | ||||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
ME-3400E-24TS-M | GLC-T (10/100/1000) | — | 12.2(44)EY | |
ME-3400EG-2CS-A | GLC-SX-MM | |||
ME-3400EG-12CS-M | GLC-LH-SM | |||
GLC-SX-MMD | 12.2(44)EY | 12.2(44)EY | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Cisco ME 3800X | ME-3800X-24FS-M (client ports) | GLC-T (10/100/1000) GLC-SX-MM GLC-LH-SM SFP-GE-T (10/100/1000) GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM SFP-GE-S SFP-GE-L GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) |
— 12.2(52)EY |
12.2(52)EY 12.2(52)EY |
ME-3800X-24FS-M (SFP+ ports) | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD GLC-ZX-SM SFP-GE-S SFP-GE-L GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) |
— 12.2(52)EY |
12.2(52)EY 12.2(52)EY |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Cisco ME 4900 Series | ME-4924-10GE | GLC-T (1000BASE-T) | — | 12.2(31)SGA |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(31)SGA | 12.2(31)SGA | ||
GLC-BX-U | ||||
CDWM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG |
Catalyst 2900 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2900 series | WS-C2980G-A | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
7.2.1 | Not supported |
WS-C2948G | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
7.2 | Not supported | |
WS-C2948G-L3 | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
7.2 | Not supported | |
Catalyst 2900 series (continued) | WS-C2948G-GE-TX | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP |
8.2(1)GLX | Not supported |
WS-C2912MF-XL with WS-X2931-XL |
WS-G5482 WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
Not supported Not supported |
12.0(5)XW 12.0(5)WC3b 12.0(5)WC5 | |
WS-C2924M-XL-EN with WS-X2931-XL | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
Not supported | 12.0(5)WC3b 12.0(5)WC5 | |
WS-C2924M-XL-EN-DC with WS-X2931-XL | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
Not supported | 12.0(5)WC3b 12.0(5)WC5 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2940 Series | WS-C2940-8TF-S | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.1(13)AY |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2950 Series | WS-C2950G-12-EI WS-C2950G-24-EI WS-C2950G-24-EI-DC WS-C2950G-48-EI |
WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC DWDM GBIC |
Not supported | 12.1(6)EA2b 12.1(12c)EA1 12.1(20)EA2 |
WS-C2950ST-8 LRE WS-C2950ST-24 LRE WS-C2950ST-24 LRE997 |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.1(19)EA1c |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Catalyst 2960 series | WS-C2960-24TC-L WS-C2960G-24TC-L WS-C2960-48TC-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(25)FX |
WS-C2960-24PC-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(44)SE | |
WS-C2960-24TC-S WS-C2960-48TC-S |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(37)EY | |
WS-C2960-8TC-S | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(46)SE | |
WS-C2960-48PST-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(46)SE | |
Catalyst 2960 series (continued) | WS-C2960-8TC-L WS-C2960G-8TC-L | GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(35)SE |
WS-C2960G-48TC-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(25)SEE | |
WS-C2960-48PST-S WS-C2960-24PC-S WS-C2960-24LT-S | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(50)SE |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2960-S Series | WS-C2960S-24TS-S | GLC-T (1000BASE-T) | Not supported | 12.2(53)SE1 |
WS-C2960S-48TS-S | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
WS-C2960S-48FPS-L | GLC-T (1000BASE-T) | Not supported | 12.2(53)SE1 | |
WS-C2960S-48LPS-L | GLC-SX-MM | |||
WS-C2960S-24PS-L | GLC-LH-SM | |||
WS-C2960S-48TS-L | GLC-ZX-SM | |||
WS-C2960S-24TS-L | GLC-BX-D | |||
GLC-BX-U | ||||
CWDM SFP | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
WS-C2960S-48FPD-L | GLC-SX-MM | Not supported | 12.2(53)SE1 | |
WS-C2960S-48LPD-L | GLC-LH-SM | |||
WS-C2960S-24PD-L | GLC-ZX-SM | |||
WS-C2960S-48TD-L | GLC-BX-D | |||
WS-C2960S-24TD-L | GLC-BX-U | |||
CWDM SFP | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2960-C Series | WS-C2960CG-8TC-L | GLC-SX-MM | Not supported | 12.2(55)EX1 |
GLC-SX-MMD | ||||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
WS-C2960C-8TC-S | GLC-SX-MM | Not supported | 12.2(55)EX3 | |
GLC-SX-MMD | ||||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
WS-C2960C-8TC-L | GLC-SX-MM | Not supported | 12.2(55)EX3 | |
WS-C2960C-8PC-L | GLC-SX-MMD | |||
WS-C2960C-12PC-L | GLC-LH-SM | |||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2970 series | WS-C2970G-24TS-E | GLC-T (10/100/1000) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.1(14)EA1 |
Minimum Software Release Required | ||||
Catalyst Operating | ||||
Platform | Switch or Module | Transceiver Module | System | Cisco IOS Release |
Catalyst 2975 Series | WS-C2975GS-48PS-L | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
Not supported | 12.2(46)EX |
Catalyst 3500 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3500XL Series | WS-C3508G-XL-EN | WS-G5482 | — | 12.0(5)XW |
WS-C3512-XL-EN | WS-G5483 | 12.0(5)WC3b | ||
WS-C3524-XL-EN | WS-G5484 | |||
WS-C3524-PWR-XL-EN | WS-G5486 | |||
WS-C3548-XL-EN | WS-G5487 | |||
CWDM GBIC |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3550 Series | WS-C3550-24-SMI | WS-G5482 | — | 12.1(6)EA1a |
WS-C3550-24-EMI | WS-G5483 | 12.1(8)EA1b | ||
WS-C3550-24-DC-SMI | WS-G5484 | |||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | 12.1(12c)EA1 | |||
DWDM GBIC | 12.1(20)EA2 | |||
WS-C3550-24-FX-SMI | WS-G5482 | — | 12.1(12c)EA1 | |
WS-C3550-24PWR-SMI | WS-G5483 | |||
WS-C3550-24PWR-EMI | WS-G5484 | |||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.1(20)EA2 | |||
WS-C3550-48-SMI | WS-G5482 | — | 12.1(8)EA1b | |
WS-C3550-48-EMI | WS-G5483 | |||
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | 12.1(12c)EA1 | |||
DWDM GBIC | 12.1(20)EA2 | |||
WS-C3550-12G | WS-G5482 | — | 12.1(6)EA1 | |
WS-C3550-12T | WS-G5483 | 12.1(8)EA1b | ||
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | 12.1(12c)EA1 | |||
DWDM GBIC | 12.1(20)EA2 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560 Series | WS-C3560-24PS | GLC-T (10/100/1000) | — | 12.1(19)EA1c |
WS-C3560-48PS | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.1(19)EA1c | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | ||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560G-24TS | GLC-T (10/100/1000) | — | 12.2(20)SE3 | |
WS-C3560G-48TS | GLC-SX-MM | |||
WS-C3560G-48PS | GLC-LH-SM | |||
WS-C3560G-24PS | GLC-SX-MMD | 12.2(46)SE | 12.2(20)SE3 | |
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | ||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560-48TS | GLC-T (10/100/1000) | — | 12.2(20)SE3 | |
WS-C3560-24TS | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(20)SE3 | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | ||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560-8PC | GLC-T (10/100/1000) | — | 12.2(35)SE | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(35)SE | ||
CWDM SFP | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | ||
WS-C3560-12PC-S | GLC-SX-MM | — | 12.2(46)SE | |
GLC-LH-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | 12.2(46)SE | 12.2(46)SE | ||
CWDM SFP | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
WS-C3560V2-24PS | GLC-T (10/100/1000) | — | 12.2(50)SE | |
WS-C3560V2-24TS | GLC-SX-MM | |||
WS-C3560V2-48PS | GLC-LH-SM | |||
WS-C3560V2-48TS | GLC-SX-MMD | 12.2(50)SE | 12.2(50)SE | |
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
CWDM SFP | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560-E Series | WS-C3560E-12SD | GLC-T (10/100/1000) | — | 12.2(44)SE |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-SX-MMD | 12.2(46)SE | 12.2(44)SE | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | ||
WS-C3560E-12SD | GLC-T (10/100/1000) | — | 12.2(44)SE | |
With CVR-X2-SFP (for X2 ports) | GLC-SX-MM GLC-LH-SM |
|||
GLC-SX-MMD | 12.2(46)SE | 12.2(44)SE | ||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560-X Series | WS-C3560X-24T | GLC-T (10/100/1000) | — | 12.2(53)SE |
WS-C3560X-48T | GLC-SX-MM | |||
WS-C3560X-24P | GLC-LH-SM | |||
WS-C3560X-48P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3560X-48PF | GLC-LH-SMD | |||
With C3KX-NM-1G and C3KX-NM-10G (slots 1 and 3) network modules |
GLC-ZX-SM GLC-BX-D GLC-BX-U |
|||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3560X-24T | GLC-SX-MM | — | 12.2(53)SE | |
WS-C3560X-48T | GLC-LH-SM | |||
WS-C3560X-24P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3560X-48P | GLC-LH-SMD | |||
WS-C3560X-48PF | GLC-ZX-SM | |||
With C3KX-NM-10G | GLC-BX-D | |||
(slots 2 and 4) and | GLC-BX-U | |||
C3KX-SM-10G network modules | SFP-GE-S SFP-GE-L |
|||
SFP-GE-Z | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Dom Support | Cisco IOS Release | |||
Catalyst 3560-C Series | WS-C3560CG-8TC-S | GLC-SX-MM | — | 12.2(55)EX |
WS-C3560CG-8PC-S | GLC-SX-MMD | |||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
WS-C3560C-8PC-S | GLC-SX-MM | — | 12.2(55)EX3 | |
WS-C3560C-12PC-S | GLC-SX-MMD | |||
GLC-LH-SM | ||||
GLC-LH-SMD | ||||
GLC-ZX-SM | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP |
Catalyst 3700 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst 3750-E Series | WS-C3750E-24TD | GLC-T (10/100/1000) | — | 12.2(35)SE2 |
WS-C3750E-24PD | GLC-SX-MM | |||
WS-C3750E-48TD | GLC-LH-SM | |||
WS-C3750E-48PD | GLC-SX-MMD | 12.2(46)SE | 12.2(35)SE2 | |
WS-C3750E-48PDF | GLC-LH-SMD | |||
With CVR-X2-SFP (for X2 ports) | GLC-ZX-SM GLC-BX-D |
|||
GLC-BX-U | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | ||
DOM Support | Cisco IOS Release | ||||
Catalyst 3750 series | WS-C3750G-12S | GLC-T (10/100/1000) | — | 12.1.(14)EA1 | |
WS-C3750G-24TS | GLC-SX-MM | ||||
WS-C3750G-48TS | GLC-LH-SM | ||||
WS-C3750G-24PS | GLC-SX-MMD | 12.2(46)SE | 12.1(14)EA1 | ||
WS-C3750G-48PS | GLC-LH-SMD | ||||
GLC-ZX-SM | |||||
CWDM SFP | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | |||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24TS | GLC-T (10/100/1000) | — | 12.1(14)EA1 | ||
WS-C3750-48TS | GLC-SX-MM | ||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.1(14)EA1 | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | 12.2(46)SE | 12.1(19)EA1c | |||
CWDM SFP | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | |||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24PS | GLC-T (10/100/1000) | — | 12.1(19)EA1c | ||
WS-C3750-48PS | GLC-SX-MM | ||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.1(19)EA1c | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
CWDM SFP | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
GLC-BX-D | 12.2(46)SE | 12.2(25)SEB | |||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24FS-S | GLC-T (10/100/1000) | — | 12.2(25)SEB | ||
GLC-SX-MM | |||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)SEB | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
CWDM SFP | |||||
GLC-BX-D | |||||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750-24WFS | GLC-T (1000BASE-T) | — | 12.2(25)FZ | ||
GLC-SX-MM | |||||
GLC-LH-SM | |||||
GLC-SX-MMD | 12.2(46)SE | 12.2(25)FZ | |||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
CWDM SFP | |||||
GLC-BX-D | |||||
GLC-BX-U | |||||
DWDM SFP | 12.2(46)SE | 12.2(40)SE | |||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE | |||
WS-C3750V2-24PS | GLC-T (10/100/1000) | — | 12.2(50)SE | ||
WS-C3750V2-24TS | GLC-SX-MM | ||||
WS-C3750V2-48PS | GLC-LH-SM | ||||
WS-C3750V2-48TS | GLC-SX-MMD | 12.2(50)SE | 12.2(50)SE | ||
GLC-LH-SMD | |||||
GLC-ZX-SM | |||||
SFP-GE-S | |||||
SFP-GE-L | |||||
SFP-GE-Z | |||||
CWDM SFP | |||||
GLC-BX-D | |||||
GLC-BX-U | |||||
DWDM SFP | |||||
DWDM SFP (add.) | 12.2(52)SE | 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst 3750-X Series | WS-C3750X-24T | GLC-T (10/100/1000) | — | 12.2(53)SE |
WS-C3750X-48T | GLC-SX-MM | |||
WS-C3750X-24P | GLC-LH-SM | |||
WS-C3750X-48P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3750X-48PF | GLC-LH-SMD | |||
With C3KX-NM-1G and | GLC-ZX-SM | |||
C3KX-NM-10G (slots 1 and 3) network modules |
GLC-BX-D GLC-BX-U |
|||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3750X-24T | GLC-SX-MM | — | 12.2(53)SE | |
WS-C3750X-48T | GLC-LH-SM | |||
WS-C3750X-24P | GLC-SX-MMD | 12.2(53)SE | 12.2(53)SE | |
WS-C3750X-48P | GLC-LH-SMD | |||
WS-C3750X-48PF | GLC-ZX-SM | |||
With C3KX-NM-10G | GLC-BX-D | |||
(slots 2 and 4) and | GLC-BX-U | |||
C3KX-SM-10G network modules | CWDM SFP SFP-GE-S |
|||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3750X-12S | GLC-T (10/100/1000) | — | 12.2(58)SE1 | |
WS-C3750X-24S | GLC-SX-MM | |||
Client ports and uplink | GLC-LH-SM | |||
ports with C3KX-NM-1G and C3KX-NM-10G | GLC-SX-MMD GLC-LH-SMD |
12.2(58)SE1 | 12.2(58)SE1 | |
(slots 1 and 3) network modules | GLC-ZX-SM GLC-BX-D |
|||
GLC-BX-U | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
WS-C3750X-12S | GLC-SX-MM | — | 12.2(58)SE1 | |
WS-C3750X-24S | GLC-LH-SM | |||
Uplink ports with | GLC-SX-MMD | 12.2(58)SE1 | 12.2(58)SE1 | |
C3KX-NM-10G (slots 2 and 4) and C3KX-SM-10G network modules | GLC-LH-SMD GLC-ZX-SM GLC-BX-D |
|||
GLC-BX-U | ||||
CWDM SFP | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
DWDM SFP | ||||
DWDM SFP (add.) |
Industrial Ethernet and Smart Grid Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Cisco 2500 Connected Grid Switch Series | CGS-2520-24TC CGS-2520-16S-8PC |
GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD GLC-BX-D GLC-BX-U SFP-GE-S SFP-GE-L GLC-EX-SMD SFP-GE-Z CWDM SFP |
Not supported | 12.2(53)EX |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Catalyst Operating System | Cisco IOS Release | |||
Cisco 2000 Connected Grid Router Series | CGR 2010 | GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD |
Not supported | 15.1(1)T |
Catalyst 4500 and Catalyst 4900 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Cisco IOS Support | DOM Support | |||
Catalyst 4500 series | WS-X4013 | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CDWM GBIC |
Not supported | — |
WS-X4013+ | WS-G5483 | 12.1(19)EW | — | |
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CDWM GBIC | ||||
DWDM GBIC | 12.1(19)EW | |||
WS-X4013+TS | GLC-SX-MM | 12.2(20)EWA | — | |
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(20)EWA | 12.2(20)EWA | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG | ||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4013+10GE | GLC-SX-MM | 12.2(25)SG | — | |
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(25)SG | 12.2(25)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG | ||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4014 | WS-G5483 | 12.1(13)EW | — | |
WS-X4232-GB-RJ | WS-G5484 | 12.1(8a)EW | — | |
WS-X4306-GB | WS-G5486 | |||
WS-X4412-2GB-T | WS-G5487 | |||
CWDM GBIC | 12.1(12c)EW | — | ||
DWDM GBIC | 12.1(19)EW | 12.2(19)EW | ||
WS-X4418-GB | WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
12.1(8a)EW 12.1(12c)EW |
— — | |
DWDM GBIC | 12.1(19)EW | 12.2(19)EW | ||
WS-X4302-GB | WS-G5483 | 12.1(19)EW | — | |
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.1(19)EW | 12.2(19)EW | ||
WS-4448-GB-SFP | GLC-T (1000BASE-T) | 12.2(20)EW | — | |
GLC-SX-MM | — | |||
GLC-LH-SM | — | |||
GLC-ZX-SM | — | |||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
CWDM SFP | 12.2(20)EW | 12.2(20)EW | ||
GLC-BX-D | 12.2(20)EWA | 12.2(20)EWA | ||
GLC-BX-U | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4506-GB-T | GLC-SX-MM | 12.2(20)EWA | — | |
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(20)EWA | 12.2(20)EWA | ||
GLC-BX-U | ||||
CWDM SFP | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4515 | WS-G5483 | 12.1(13)EW | — | |
WS-G5484 | 12.1(12c)EW | — | ||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.1(19)EW | 12.1(19)EW | ||
WS-X4516 | WS-G5483 | 12.2(18)EW | — | |
WS-G5484 | ||||
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
DWDM GBIC | 12.2(18)EW | 12.2(18)EW | ||
WS-X4516-10GE | GLC-T (1000BASE-T) | 12.2(25)EWA | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(25)EWA | 12.2(25)EWA | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | 12.2(37)SG | 12.2(37)SG | ||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X45-SUP6-E | GLC-T | 12.2(40)SG | — | |
WS-X4606-X2 | GLC-SX-MM | |||
with CVR-X2-SFP Twin | GLC-LH-SM | |||
Gig converter | GLC-ZX-SM | |||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(40)SG | 12.2(40)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-4624-SFP-E | GLC-T (1000BASE-T) | 12.2(44)SG | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(44)SG | 12.2(44)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X45-SUP6L-E | GLC-T (1000BASE-T) | 12.2(52)SG | — | |
with CVR-X2-SFP Twin | GLC-SX-MM | |||
Gig converter | GLC-LH-SM | |||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(52)SG | 12.2(52)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(53)SG3 | 12.2(53)SG3 | ||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4612-SFP-E | GLC-T (1000BASE-T) | 12.2(54)SG | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 12.2(54)SG | 12.2(54)SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4640-CSFP-E | GLC-T (1000BASE-T) | 15.0(2)SG | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 15.0(2)SG | 15.0(2)SG | ||
GLC-2BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X4712-SFP+E | GLC-T (1000BASE-T) | 3.1.0SG | — | |
WS-X45-SUP7-E | GLC-SX-MM | |||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 3.1.0SG | 3.1.0SG | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG | ||
WS-X45-SUP7L-E | GLC-T (1000BASE-T) | 3.2.0XO | — | |
GLC-SX-MM | ||||
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD | ||||
GLC-BX-D | 3.2.0XO | 3.2.0XO | ||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
Cisco IOS Support | DOM Support | |||
Catalyst 4500-X Series | WS-C4500X-32SFP+ | GLC-T (1000BASE-T) | 3.3.0SG | — |
WS-C4500X-F-32SFP+ | GLC-SX-MM | |||
WS-C4500X-40X-ES | GLC-LH-SM | |||
C4KX-NM-8SFP+ | GLC-ZX-SM | |||
GLC-SX-MMD | 3.3.0SG | 3.3.0SG | ||
GLC-LH-SMD | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | ||||
GLC-EX-SMD | 15.1(1)SG | 15.1(1)SG |
Catalyst 6500 Switches Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | ||
Catalyst Operating System | Cisco IOS Release | DOM Support | |||
Catalyst 6500 Series |
WS-X6K-SUP1-2GE WS-X6K-SUP1A-2GE WS-X6K-SUP1A-MSFC WS-X6K-SUP1A-MSFC2 WS-X6K-SUP1A-PFC WS-X6K-SUP2U-MSFC2 WS-X6K-S2-PFC2 |
WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
7.2 Please see release notes for details 7.2 |
12.1(13)E Please see release notes for details 12.1(13)E |
— |
WS-X6K-SUP2-MSFC2 WS-X6K-SUP2U-PFC2 WS-X6408-GBIC WS-X6408A-GBIC WS-X6416-GBIC WS-X6516-GBIC WS-X6816-GBIC |
WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC DWDM GBIC |
7.2 Please see release notes for details 7.2 8.3.1 |
12.1(13)E Please see release notes for details 12.1(13)E 12.2(17a)SX |
— | |
WS-X6516A-GBIC | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC DWDM GBIC |
7.5.1 Please see release notes for details 7.5.1 8.3.1 |
12.1(19)E1 Please see release notes for details 12.1(19)E1 12.2(17a)SX |
— | |
WS-SUP720 | GLC-T(1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
8.3.1 8.1.1 8.1.1 8.2 8.4.1 8.4.1 8.3.1 — — — |
12.2(17a)SX 12.2(14)SX 12.2(17a)SX 12.2(17d)SXB1 12.2(18)SXE1 12.2(18)SXE1 12.2(17a)SX 12.2(33)SXH 12.2(14)SX 12.2(17a)SX |
— — — — 12.2(18)SXE1 12.2(18)SXE1 12.2(18)SXE 12.2(33)SXH — — | |
WS-SUP720-3B WS-SUP720-3BXL |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
8.3.2 8.3.2 8.3.2 8.3.2 8.4.1 8.4.1 8.3.2 — — — |
12.2(17d)SXB1 12.2(17d)SXB1 12.2(17d)SXB1 12.2(17d)SXB1 12.2(18)SXE1 12.2(18)SXE1 12.2(17d)SXB1 12.2(33)SXH 12.2(17d)SXB1 12.2(17d)SXB1 |
— — — — 12.2(18)SXE1 12.2(18)SXE1 12.2(18)SXE 12.2(33)SXH — — | |
WS-SUP32-GE-3B WS-SUP32-10GE-3B |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
8.4(1) 8.4(1) 8.4(1) 8.4(1) 8.4(1) 8.4(1) 8.4(1) — — — |
12.2(18)SXF 12.2(18)SXF 12.2(18)SXF 12.2(18)SXF 12.2(18)SXF 12.2(18)SXF 12.2(18)SXF 12.2(33)SXH 12.2(18)SXF 12.2(18)SXF |
— — — — 12.2(18)SXF 12.2(18)SXF 12.2(18)SXF 12.2(33)SXH — — | |
WS-SUP32-GE-PISA | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 12.2(18)ZY | — | |
VS-S720-10G-3C VS-S720-10G-3CXL |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 12.2(33)SXH | — — — — 12.2(33)SXH 12.2(33)SXH 12.2(33)SXH 12.2(33)SXH — — | |
WS-X6724-SFP WS-X6748-SFP |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
8.3.1 8.1.1 8.1.1 8.2 8.4.1 8.4.1 8.3.1 — — — |
12.2(17a)SX 12.2(14)SX 12.2(17a)SX 12.2(17d)SXB1 12.2(18)SXE1 12.2(18)SXE1 12.2(17a)SX 12.2(33)SXH 12.2(14)SX 12.2(17a)SX |
— | |
VS-S2T-10G VS-S2T-10G-XL WS-X6824-SFP-2T WS-X6824-SFP-2TXL WS-X6848-SFP-2T WS-X6848-SFP-2TXL |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM-SFP DWDM-SFP GLC-SX-MMD GLC-LH-SMD |
— | 12.2(50)SY | — |
Data Center and Blade Switching Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Catalyst 2350 Series | 2350-48TD-S 2350-48TD-SD (with CVR-X2-SFP TwinGig converter) |
GLC-T GLC-SX-MM GLC-SX-MMD |
— | Cisco IOS 12.2(46)EY |
Cisco Catalyst 2360 Series | 2360-48TD-S | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | Cisco IOS 12.2(53)EY |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Catalyst 3000 and 3100 Blade Switches | WS-CBS3020-HPQ | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | Cisco IOS 12.2(35)SE |
WS-CBS3030-DEL WS-CBS3040-FSC |
GLC-T (1000BASE-T) GLC-SX-MM GLC-SX-MMD |
— | Cisco IOS 12.2(35)SE | |
WS-CBS-3120G-S WS-CBS-3130G-S (with CVR-X2-SFP TwinGig converter) |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | Cisco IOS 12.2(40)EX1 | |
WS-CBS3032-DEL (with CVR-X2-SFP TwinGig converter) |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | Cisco IOS 12.2(40)EX1 | |
WS-CBS3110X-S (with CVR-X2-SFP TwinGig converter) |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | Cisco IOS 12.2(52)SE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Nexus 2000 Series | N2K-C2232PP-10GE | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | NX-OS 4.2(1)N2(1) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Nexus 3000 Series | N3K-C3064PQ | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | NX-OS 5.0(3)U1(1d) |
N3K-C3064PQ-10GE | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | NX-OS 5.0(3)U1(2) | |
N3K-C3048TP-1GE | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | NX-OS 5.0(3)U2(2b) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Nexus 4000 Series | N4K-4001I-XPX | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | NX-OS 4.1(2)E1(1) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Nexus 5000 Series | N5K-C5010P-BF N5K-C5020P-BF |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM SFP-GE-T (1000BASE-T) SFP-GE-S SFP-GE-L GLC-SX-MMD GLC-LH-SMD |
— NX-OS 4.0(1a)N1(1) |
NX-OS 4.0(1a)N1(1) NX-OS 4.0(1a)N1(1) |
N5K-C5548P-FA N5K-C5548UP-FA N5KC5596UP-FA N55-M16P N55-M8P8FP N55-M16UP |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM SFP-GE-T (1000BASE-T) SFP-GE-S SFP-GE-L GLC-SX-MMD GLC-LH-SMD |
— NX-OS 5.0(3)N1(1B) |
NX-OS 5.0(3)N1(1B) NX-OS 5.0(3)N1(1B) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Unified Computing System | N10-S6100 N10-S6200 N10-E0440 N10-E0600 N20-I6584 |
SFP-GE-S SFP-GE-L GLC-SX-MMD GLC-LH-SMD GLC-SX-MM GLC-LH-SM GLC-T (1000BASE-T) SFP-GE-T (1000BASE-T) |
UCS Manager v1.3 — |
UCS Manager v1.3 UCS Manager v1.3 |
UCS-FI-6248UP UCS-FI-E16UP UCS-IOM-2208XP |
SFP-GE-S SFP-GE-L GLC-SX-MMD GLC-LH-SMD GLC-SX-MM GLC-LH-SM GLC-T (1000BASE-T) SFP-GE-T (1000BASE-T) |
UCS Manager v2.0(1) — |
UCS Manager v2.0(1) UCS Manager v2.0(1) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco Nexus 7000 Series |
N7K-F248XP-25 | GLC-T (1000BASE-T) SFP-GE-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD SFP-GE-S GLC-LH-SMD SFP-GE-L SFP-GE-Z GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP |
— NX-OS 6.0 |
NX-OS 6.0 NX-OS 6.0 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco CSS 11500 Series | CSS11506-2AC CSS11506-2DC CSS11503-AC CSS11503-DC CSS11501 CSS5-SCM-2GE CSS5-IOM-2GE |
GLC-T GLC-SX-MM GLC-LH-SM |
— | WebNS 7.5 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco MDS 9000 Series | Please refer to: http://www/en/US/prod/collateral/ps4159/ps6409/ps4358/product_data_sheet09186a00801bc698.html |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 892F Series | CISCO892F-K9 CISCO892FW-K9 |
GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U GLC-SX-MMD GLC-LH-SMD |
Not supported | 15.1(2)T |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 2900 Series Router | Cisco 2921 Cisco 2951 |
GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-U GLC-BX-D CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M |
HWIC-1GE-SFP | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M | |
SM-D-ES3G-48-P SM-D-ES3-48-P SM-D-ES2-48 |
GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-U GLC-BX-D CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M | |
EHWIC-1GE-SFP-CU | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.1(4)M |
Router Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 1921 Series Router | HWIC-1GE-SFP | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M2 |
EHWIC-1GE-SFP-CU | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.1(4)M |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco1941 Series Router | HWIC-1GE-SFP | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M |
EHWIC-1GE-SFP-CU | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.1(4)M |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 2600 Series Router | NM-1GE | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
— | 12.2(11)YT |
NME-XD-24ES-1S-P NME-XD-48ES-2S-P |
GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)EZ |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 2800 Series Router | NME-XD-24ES-1S-P NME-XD-48ES-2S-P |
GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)EZ |
HWIC-1GE-SFP | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 12.3(8)T4 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 3200 Series Rugged Routers | Cisco 3270 | GLC-SX-MM-RGD GLC-LX-SM-RGD |
— | 12.4(6)XE |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 3600 Series Router | NM-1GE | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
— | 12.2(11)YT |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 3700 Series Router | NM-1GE | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
— | 12.2(11)YT |
NME-XD-24ES-1S-P NME-XD-48ES-2S-P |
GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)EZ |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 3800 Series Router | NM-1GE | WS-G5483 WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
— | 12.2(11)YT |
NME-XD-24ES-1S-P NME-XD-48ES-2S-P |
GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)EZ | |
HWIC-1GE-SFP | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 12.3(8)T4 | |
Cisco 3825 | GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 12.3(11)T | |
Cisco 3845 | GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 12.3(11)T |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 3900 Series Router | Cisco 3925 Cisco 3945 |
GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-U GLC-BX-D CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M |
HWIC-1GE-SFP | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M | |
SM-D-ES3G-48-P SM-D-ES3-48-P SM-D-ES2-48 |
GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-U GLC-BX-D CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.0(1)M | |
EHWIC-1GE-SFP-CU | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP GLC-SX-MMD GLC-LH-SMD |
— | 15.1(4)M |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 6400 Universal Access Router | C6400-NRP-2SV | WS-G5484 WS-G5486 WS-G5487 |
— | 12.2(2)B6 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 7200 Series Router | NPE-G1 | WS-G5484 | — | 12.0(28)S |
The Cisco 7200 series | WS-G5486 | 12.1(14)E | ||
router supports multiple | WS-G5487 | 12.2(15)B | ||
parallel release | CWDM GBIC | 12.2(4)BW | ||
branches. Where several | 12.2(14)S | |||
releases are grouped | 12.2(14)SU | |||
together, they provide | 12.2(15)T9 | |||
support for all transcievers in the | Cisco 7201 | GLC-SX-MM | — | 12.2(33)SRC2 |
corresponding group. | GLC-SX-MMD | 12.4(15)T7 | ||
12.4(20)T1 | ||||
SFP-GE-T | — | 12.2(33)SRC2 | ||
12.4(15)T7 | ||||
SFP-GE-S | — | 12.2(31)SB2 | ||
SFP-GE-L | 12.2(33)SRC2 | |||
GLC-LH-SMD | 12.4(15)T7 | |||
SFP-GE-Z | ||||
CWDM SFP | ||||
NPE-G2 | GLC-SX-MM | — | 12.2(33)SRC2 | |
GLC-SX-MMD | 12.4(15)T7 | |||
12.4(20)T1 | ||||
SFP-GE-S | — | 12.2(31)SB2 | ||
SFP-GE-L | 12.2(33)SRC2 | |||
GLC-LH-SMD | 12.4(15)T7 | |||
SFP-GE-Z | ||||
CWDM SFP | ||||
C7200-I/O-GE+E | WS-G5484 | — | 12.0(14)S2 | |
WS-G5486 | 12.1(3a)E5 | |||
WS-G5487 | 12.1(5)T1 | |||
PA-GE | WS-G5484 | — | 12.0(7)S | |
WS-G5486 | 12.0(6)T | |||
WS-G5487 | 12.1(1)E |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco uBR7200 Series | uBR7200-NPE-G1 | WS-G5484 | — | 12.2(11)CX |
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | ||||
uBR7200-NPE-G2 | GLC-SX-MMD | 12.2SB | 12.2SB | |
GLC-LH-SMD | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
CWDM SFP |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 7300 Series Router | CISCO7301 | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(18)S1 |
7300-NSE-100 | WS-G5484 WS-G5486 WS-G5487 WS-G5483 CWDM GBIC |
— | 12.2(20)S 12.2(28)SB | |
7304-NPE-G100 | GLC-SX-MM GLC-LH-SM GLC-ZX-SM CWDM SFP |
— | 12.2(20)S | |
7300-NSE-150 | GLC-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD GLC-BX-D GLC-BX-U SFP-GE-S SFP-GE-L SFP-GE-Z CWDM SFP |
— 12.2(31)SB2 |
12.2(31)SB2 12.2(31)SB2 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 7500 Series Router | GEIP | WS-G5484 WS-G5486 WS-G5487 |
— | Please see release notes |
GEIP+ | WS-G5484 WS-G5486 WS-G5487 |
— | Please see release notes |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 7600 Series Router | OSM-1CHOC12/T1-SI OSM-1CHOC12/T3-SI OSM-2OC12-ATM-MM OSM-2OC12-ATM-SI OSM-2OC12-ATM-MM+ OSM-2OC12-ATM-SI+ OSM-4OC3-POS-SI OSM-4OC3-POS-SI+ OSM-4OC12-POS-SI OSM-4OC12-POS-SI+ OSM-8OC3-POS-MM OSM-8OC3-POS-SI OSM-8OC3-POS-SL OSM-8OC3-POS-SL+ OSM-8OC3-POS-SI+ OSM-16OC3-POS-MM OSM-16OC3-POS-SI OSM-16OC3-POS-SL OSM-16OC3-POS-SI+ OSM-2OC12-POS-MM OSM-2OC12-POS-SI OSM-2OC12-POS-SL OSM-2OC12-POS-SI+ OSM-2OC12-POS-MM+ OSM4OC12-POS-MM OSM4OC12-POS-SI OSM4OC12-POS-SL OSM4OC12-POS-SI+ OSM-1OC48-POS-SI OSM-1OC48-POS-SL OSM-1OC48-POS-SS OSM-1OC48-POS-SS+ OSM-10C48-POS-SI+ OSM-1OC48-POS-SL+ OSM-2OC48/1DPT-SS OSM-2OC48/1DPT-SI OSM-2OC48/1DPT-SL OSM-2+4GE-WAN+ OSM-4GE-WAN-GBIC |
WS-G5484 WS-G5486 WS-G5487 CWDM GBIC |
— | Please see release notes |
WS-SUP720 WS-SUP720-3B WS-SUP720-3BXL |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD CWDM SFP |
— 12.2(33)SRA |
12.2(33)SRA 12.2(33)SRA | |
WS-SUP32-GE-3B | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP |
— 12.2(33)SRA 12.2(33)SRB 12.2(33)SRE |
12.2(33)SRA 12.2(33)SRA 12.2(33)SRB 12.2(33)SRE | |
WS-X6724-SFP WS-X6748-SFP |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-BX-D GLC-BX-U CWDM SFP GLC-SX-MMD GLC-LH-SMD SFP-GE-T (1000BASE-T) SFP-GE-S SFP-GE-L SFP-GE-Z DWDM SFP |
— — — |
12.2(33)SRA 12.2(33)SRB 12.2(33)SRE | |
RSP720-3C-GE RSP720-3CXL-GE |
GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MMD GLC-LH-SMD SFP-GE-T (1000BASE-T) GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP SFP-GE-S SFP-GE-L |
— 12.2(33)SRE1 — 12.2(33)SRE1 |
12.2(33)SRB 12.2(33)SRB 12.2(33)SRE1 12.2(33)SRE1 | |
RSP720-10GE | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM GLC-ZX-SM SFP-GE-T (1000BASE-T) GLC-BX-D GLC-BX-U SFP-GE-S SFP-GE-L GLC-SX-MMD GLC-LH-SMD CWDM SFP DWDM SFP |
— 12.2(33)SRC 12.2(33)SRE1 |
12.2(33)SRC 12.2(33)SRC 12.2(33)SRE1 | |
7600-ES20-GE3CXL 7600-ES20-GE3C |
SFP-GE-S SFP-GE-L SFP-GE-Z GLC-SX-MMD GLC-LH-SMD SFP-GE-T CWDM SFP GLC-BX-D GLC-BX-U DWDM SFP DWDM SFP (add.) |
12.2(33)SRB — 12.2(33)SRB3 12.2(33)SRD 12.2(33)SRE |
12.2(33)SRB 12.2(33)SRB3 12.2(33)SRD 12.2(33)SRE | |
7600-ES+20G3C 7600-ES+20G3CXL 7600-ES+40G3C 7600-ES+40G3CXL |
SFP-GE-T GLC-SX-MMD GLC-LH-SMD SFP-GE-S SFP-GE-L SFP-GE-Z GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) |
— 12.2(33)SRD 12.2(33)SRE |
12.2(33)SRD 12.2(33)SRD 12.2(33)SRE | |
76-ES+T-20G | SFP-GE-T | — | 12.2(33)SRD3 | |
76-ES+T-40G | GLC-SX-MMD | 12.2(33)SRD3 | 12.2(33)SRD3 | |
GLC-LH-SMD | ||||
SFP-GE-S | ||||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) | 12.2(33)SRE | 12.2(33)SRE | ||
76-ES+XC-20G3C | SFP-GE-T | — | 12.2(33)SRE | |
76-ES+XC-20G3CXL | GLC-SX-MMD | 12.2(33)SRE | 12.2(33)SRE | |
76-ES+XC-40G3C | GLC-LH-SMD | |||
76-ES+XC-40G3CXL | SFP-GE-S | |||
SFP-GE-L | ||||
SFP-GE-Z | ||||
GLC-BX-D | ||||
GLC-BX-U | ||||
CWDM SFP | ||||
DWDM SFP | ||||
DWDM SFP (add.) |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 10000 Series Router | ESR-1GE | WS-G5484 | — | Please see release |
WS-G5486 | notes | |||
WS-G5487 | ||||
ESR-HH-1GE | SFP-GE-T | — | 12.0(23)S | |
SFP-GE-S | 12.0(23)S | 12.0(23)S | ||
SFP-GE-L | ||||
SFP-GE-Z |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco RF Gateway Series | RFGW-X4516-10GE | SFP-GE-S | 12.2(44)SQ | 12.2(44)SQ |
SFP-GE-L | ||||
RFGW-DS48 | SFP-GE-T | — | 12.2(44)SQ | |
SFP-GE-S | 12.2(44)SQ | 12.2(44)SQ | ||
SFP-GE-L |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 10700 Series Internet Router | 10720-GE-FE-TX | SFP-GE-T | — | 12.0(27)S |
10720-GE-FE-TX-B | SFP-GE-S | 12.0(26)S | 12.0(26)S | |
SFP-GE-L | ||||
SFP-GE-Z | ||||
CWDM SFP | 12.0(31)S | 12.0(31)S |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco 12000 Series Router | 3GE-GBIC-SC | WS-G5484 | — | 12.0(11)S3 |
WS-G5486 | ||||
WS-G5487 | ||||
CWDM GBIC | 12.0(32)S | |||
10x1GE-SFP-LC-B | GLC-SX-MM | — | 12.0(21)S | |
GLC-LH-SM | ||||
4GE-SFP-LC | GLC-SX-MM | — | 12.0(25)S | |
GLC-LH-SM | ||||
GLC-ZX-SM | ||||
CWDM SFP | 12.0(32)S | |||
EPA-3GE-SX/LH-LC | GLC-SX-MM | — | 12.0(23)S | |
GLC-LH-SM | ||||
GLC-ZX-SM |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Shared Port Adapters (SPAs) | SPA-2X1GE | SFP-GE-T | SPA software support is determined by | |
SPA-5X1GE | SFP-GE-S | the platform on which the SPA is | ||
SPA-8X1GE | SFP-GE-L | installed. Refer to the SPA release notes | ||
SPA-10X1GE | SFP-GE-Z | for the correct software release. | ||
SPA-5X1GE-V2 | CWDM SFP | |||
SPA-8X1GE-V2 | DWDM SFP | |||
SPA-10X1GE-V2 | GLC-SX-MMD | |||
GLC-LH-SMD | ||||
SPA-2GE-7304 | SFP-GE-S | |||
SPA-2X1GE-V2 | SFP-GE-L | |||
SFP-GE-Z | ||||
CWDM SFP | ||||
DWDM SFP | ||||
GLC-SX-MMD | ||||
GLC-LH-SMD |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
CRS Router Series | CRS-16-RP | GLC-LH-SM GLC-LH-SMD |
— | XR 2.0 |
CRS-16-RP-B | GLC-LH-SM GLC-LH-SMD |
— | XR 3.3 | |
CRS-FCC-SC-22GE | GLC-LH-SM GLC-LH-SMD |
— | XR 3.4.1 | |
42-1GE 20-1GE-FLEX | SFP-GE-T (1000BASE-T) SFP-GE-S GLC-SX-MMD SFP-GE-L GLC-LH-SMD SFP-GE-Z |
— XR 3.8.1 |
XR 3.8.1 XR 3.8.1 | |
CRS-8-PRP-6G CRS-8-PRP-12G |
GLC-LH-SM GLC-LH-SMD |
— | XR 4.0.2 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
ASR 901 Series Router | A901-12C-F-D A901-12-C-FT-D |
GLC-T SFP-GE-T GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-SX-MM-RGD GLC-LX-SM-RGD SFP-GE-S SFP-GE-L SFP-GE-Z |
— 15.1(2)SNG |
15.1(2)SNG 15.1(2)SNG |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco ASR 903 Series | A900-IMA8S | SFP-GE-T GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD GLC-BX-D GLC-BX-U GLC-EX-SMD GLC-SX-MMD GLC-LH-SMD CWDM SFP DWDM SFP DWDM SFP (add.) |
— XE 3.5.0S XE 3.6.0S |
XE 3.5.0S XE 3.5.0S XE 3.6.0S |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
ASR 1000 Series Router | ASR1001 ASR1002 ASR1002-F |
SFP-GE-T SFP-GE-S SFP-GE-L SFP-GE-Z CWDM SFP DWDM SFP GLC-BX-D GLC-BX-U GLC-SX-MMD GLC-LH-SMD |
— XE 2.1 XE 2.5 XE 3.4S |
XE 2.1 XE 2.1 XE 2.5 XE 3.4S |
ASR 1000 platform with SPA cards | Software support on the ASR 1000 modular platforms is determined by the platform on which the SPA is installed. Refer to the SPA release notes for the correct software release. http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_ad apters/configuration/ASR1000/ASRspasw.pdf |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
ASR 9000 Series Router | A9K-40GE-B A9K-40GE-E |
SFP-GE-T (10/100/1000) SFP-GE-S SFP-GE-L SFP-GE-Z GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) GLC-SX-MMD GLC-LH-SMD GLC-EX-SMD |
— XR 3.7.3 XR 3.9.0 XR 4.1.1 |
XR 3.7.3 XR 3.7.3 XR 3.9.0 XR 4.1.1 |
A9K-2T20GE-B A9K-2T20GE-E A9K-2T20GE-L A9K-40GE-L |
SFP-GE-T (10/100/1000) SFP-GE-S SFP-GE-L SFP-GE-Z GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) GLC-SX-MMD GLC-LH-SMD GLC-EX-SMD |
— XR 3.9.0 XR 4.1.1 |
XR 3.9.0 XR 3.9.0 XR 4.1.1 | |
A9K-MPA-20X1GE | SFP-GE-T (10/100/1000) SFP-GE-S SFP-GE-L SFP-GE-Z GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) GLC-SX-MMD GLC-LH-SMD GLC-EX-SMD |
— XR 4.2.0 |
XR 4.2.0 XR 4.2.0 | |
A9K-RSP440-TR A9K-RSP440-SE ASR-9001 |
SFP-GE-T (10/100/1000) SFP-GE-S SFP-GE-L SFP-GE-Z GLC-BX-D GLC-BX-U CWDM SFP DWDM SFP DWDM SFP (add.) GLC-SX-MMD GLC-LH-SMD GLC-EX-SMD |
— XR 4.2.1 |
XR 4.2.1 XR 4.2.1 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM support | Cisco IOS or NX-OS Release | |||
Cisco MWR 2941 Mobile Wireless Routers |
MWR-2941-DC | GLC-SX-MMD GLC-LH-SMD SFP-GE-S SFP-GE-L SFP-GE-Z GLC-SX-MM-RGD GLC-LX-SM-RGD GLC-ZX-SM-RGD SFP-GE-T CWDM SFP DWDM SFP GLC-BX-D GLC-BX-U GLC-EX-SMD |
12.4(19)MR1 — — 12.4(19MR3/ 12.2(33)MRA 12.2(33)MRB/ 12.4(20)MRA 15.1(01)MR |
12.4(19)MR1 12.4(19)MR1 12.4(19)MR3/ 12.2(33)MRA 12.4(19MR3/ 12.2(33)MRA 12.2(33)MRB/ 12.4(20)MRA 15.1(01)MR |
Appliance Support
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
ASA5500 Series appliances | SSM-4GE | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | ASA 7.0 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
NAM 2200 Series appliances | NAM2204-SFP | GLC-T (1000BASE-T) GLC-SX-MM GLC-LH-SM |
— | NAM 4.0 |
Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
DOM Support | Cisco IOS Release | |||
Catalyst Express 500 | WS-CE500-24LC WS-CE500-24PC WS-CE500G-12TC |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)FY |