==Supervisor engines==
 
==Supervisor engines==
 +
[[image:Cisco7606 front.jpg|framed|Cisco7606-S front]]
 +
[[image:Cisco7606 rear.jpg|framed|Cisco7606-S rear]]
 
Both, the Cisco7606 and the Cisco7606-S router have six horizontal slots being numbered from top to bottom and measure 7 rack units (7 RU).<br/>
 
Both, the Cisco7606 and the Cisco7606-S router have six horizontal slots being numbered from top to bottom and measure 7 rack units (7 RU).<br/>
 
While the supported supervisor engine 2 (see below) is installed in slot 1 and an optional redundant supervisor engine 2 in slot 2, the supported supervisor engine 720 and supervisor engine 32 are installed in slot 5 (first supervisor engine)and slot 6 (optional redundant supervisor engine).<br/>
 
While the supported supervisor engine 2 (see below) is installed in slot 1 and an optional redundant supervisor engine 2 in slot 2, the supported supervisor engine 720 and supervisor engine 32 are installed in slot 5 (first supervisor engine)and slot 6 (optional redundant supervisor engine).<br/>
Line 8: Line 10:
 
'''Supported supervisor engines in the Cisco7606 router'''<br/>
 
'''Supported supervisor engines in the Cisco7606 router'''<br/>
  
*Supervisor engine 2<br/>
+
*Supervisor engine 2<br/>''!!! To be installed in slot 1 (first supervisor engine) and in slot 2 (optional redundant supervisor engine).''<br/>
**WS-X6K-S2-PFC2<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-PFC2]] <br/>
**WS-X6K-S2-MSFC2<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-MSFC2]] <br/>
**WS-X6K-S2U-MSFC2<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2U-MSFC2]]<br/>
  
*Supervisor engine 720<br/>
+
*Supervisor engine 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/>
**WS-SUP720<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/>
**WS-SUP720-3B<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]]<br/>
**WS-SUP720-3BXL<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]]<br/>
  
*Supervisor engine 32<br/>
+
*Supervisor engine 32<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/>
**WS-SUP32-GE-3B<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B]] <br/>
**WS-SUP32-10GE-3B<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]] <br/>
  
 
''!!! Note: While being supported in the Cisco7604 and the Cisco7606-S chassis, the route switch processor 720 is not supported in the ciso7606 router''
 
''!!! Note: While being supported in the Cisco7604 and the Cisco7606-S chassis, the route switch processor 720 is not supported in the ciso7606 router''
Line 26: Line 28:
 
'''Supported supervisor engines in the Cisco7606-S router'''<br/>
 
'''Supported supervisor engines in the Cisco7606-S router'''<br/>
  
*Supervisor engine 32<br/>
+
*Supervisor engine 32<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/>
**WS-SUP32-GE-3B<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B]]<br/>
**WS-SUP32-10GE-3B<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]]<br/>
  
*Supervisor engine 720<br/>
+
*Supervisor engine 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/>
**WS-SUP720<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/>
**WS-SUP720-3B<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/>
**WS-SUP720-3BXL<br/>
+
** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]]<br/>
  
*Route switch processor 720<br/>
+
*Route switch processor 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/>
 
**RSP720-3C-GE<br/>
 
**RSP720-3C-GE<br/>
 
**RSP720-3CXL-GE<br/>
 
**RSP720-3CXL-GE<br/>
Line 44: Line 46:
 
Both, the Cisco7606 and the Cisco7606-S router have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.<br/>
 
Both, the Cisco7606 and the Cisco7606-S router have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.<br/>
  
'''Supported spower supplies in the Cisco7606 router'''<br/>
+
'''Supported power supplies in the Cisco7606 router'''<br/>
*950 watt AC-input power supply<br/>
+
*1900 watt AC-input power supply<br/>
**PWR-950-AC<br/>
+
**PWR-1900-AC/6<br/>
''!!! Note: the power entry module '''PEM-15A-AC ''' is needed when using a PWR-950-AC. You need one '''PEM-15A-AC ''' per PWR-950-AC.<br/>''
+
''!!! Note: the power entry module '''PEM-20A-AC''' is needed when using a PWR-1900-AC/6. You need one '''PEM-20A-AC''' per PWR-1900-AC/6.<br/>''
 
''The power entry modules are installed on the front of the chassis on the very top.''
 
''The power entry modules are installed on the front of the chassis on the very top.''
  
*950 watt DC-input power supply<br/>
+
*1900 watt DC-input power supply<br/>
**PWR-950-DC<br/>
+
**PWR-1900-DC<br/>
''!!! Note: the power entry module '''PEM-DC/3''' is needed when using a PWR-950-DC. You need one '''PEM-DC/3''' per PWR-950-DC.<br/>''
+
''!!! Note: the power entry module '''PEM-DC''' is needed when using a PWR-1900-DC. You need one '''PEM-DC''' per PWR-1900-DC.<br/>''
 
''The power entry modules are installed on the front of the chassis on the very top.''
 
''The power entry modules are installed on the front of the chassis on the very top.''
  
*1400 watt AC-input power supply<br/>
+
*2700 watt AC-input power supply<br/>
**PWR-1400-AC<br/>
+
**PWR-2700-AC<br/>
''!!! Note: the power entry module '''PEM-20A-AC+''' is needed when using a PWR-1400-AC. You need one '''PEM-20A-AC+''' per PWR-1400-AC.<br/>''
+
''No power entry module is needed when using a PWR-2700-AC''
''The power entry modules are installed on the front of the chassis on the very top.''
+
 
 +
*2700 watt DC-input power supply<br/>
 +
**PWR-2700-DC<br/>
 +
''No power entry module is needed when using a PWR-2700-DC''
 +
 
 +
'''Supported power supplies in the Cisco7606-S router'''<br/>
 +
*2700 watt AC-input power supply<br/>
 +
**PWR-2700-AC<br/>
 +
''No power entry module is needed when using a PWR-2700-AC''
  
'''Supported spower supplies in the Cisco7603-S router'''<br/>
+
*2700 watt DC-input power supply<br/>
*1500 watt DC-input power supply<br/>
+
**PWR-2700-DC<br/>
**PWR-1500-DC<br/>
+
''No power entry module is needed when using a PWR-2700-DC''
''!!! Note: the power entry module '''PEM-1500W-DC/03S''' is needed when using a PWR-1500-DC. You need one '''PEM-1500W-DC/03S''' per PWR-1500-DC.<br/>''
 
''The power entry modules are installed on the front of the chassis on the very top.''<br/>
 
'''''There is no longer an AC power supply option for the Cisco7603-S router'''''
 
  
 
==Fan trays==
 
==Fan trays==
  
'''Supported fan trays in the Cisco7603 router'''<br/>
+
'''Supported fan trays in the Cisco7606 router'''<br/>
 
*standard fan module<br/>
 
*standard fan module<br/>
**FAN-MOD-3<br/>
+
**WS-C6K-6SLOT-FAN<br/>
 
*high speed fan module<br/>
 
*high speed fan module<br/>
**FAN-MOD-3HS<br/>
+
**FAN-MOD-6HS<br/>
''!!! Note: supervisor engine 720 configurations require the '''FAN-MOD-3HS'''. '''The FAN-MOD-3''' will only work in supervisor engine 2 configurations.''<br/>
+
''!!! Note: supervisor engine 720 configurations require the '''FAN-MOD-6HS'''. '''WS-C6K-6SLOT-FAN''' will only work in supervisor engine 2 configurations.''<br/>
  
'''Supported fan trays in the Cisco7603-S router'''<br/>
+
'''Supported fan trays in the Cisco7606-S router'''<br/>
 
*high speed fan module<br/>
 
*high speed fan module<br/>
**FAN-MOD-3SHS<br/>
+
**FAN-MOD-6SHS<br/>
''!!! Note: As a result of the sup 32 being the minimum required supervisor engine for the Cisco7603-S, no standard fan tray is supported in any cisco7603-S configuration. Both high speed fans, the FAN-MOD-3SHS and the FAN-MOD-3HS will work in the Cisco7603-S. With the FAN-MOD-3SHS being white, the colour would be the only difference.''
+
''!!! Note: As a result of the sup 32 being the minimum required supervisor engine for the Cisco7606-S, no standard fan tray is supported in any cisco7606-S configuration. Both high speed fans, the FAN-MOD-6SHS and the FAN-MOD-6HS will work in the Cisco7606-S. With the FAN-MOD-6SHS being white, the colour would be the only difference.''

Latest revision as of 09:43, 2 July 2009

Supervisor engines

Cisco7606-S front
Cisco7606-S rear

Both, the Cisco7606 and the Cisco7606-S router have six horizontal slots being numbered from top to bottom and measure 7 rack units (7 RU).
While the supported supervisor engine 2 (see below) is installed in slot 1 and an optional redundant supervisor engine 2 in slot 2, the supported supervisor engine 720 and supervisor engine 32 are installed in slot 5 (first supervisor engine)and slot 6 (optional redundant supervisor engine).
!!! Note: When installing a redundant supervisor engine, both supervisor engines must be identical.
!!! Note: The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by.
If a redundant supervisor engine is not required, all free slots can be equipped with any supported cisco7600 series / catalyst 6500 series module.

Supported supervisor engines in the Cisco7606 router

  • Supervisor engine 32
    !!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).

!!! Note: While being supported in the Cisco7604 and the Cisco7606-S chassis, the route switch processor 720 is not supported in the ciso7606 router

Supported supervisor engines in the Cisco7606-S router

  • Supervisor engine 32
    !!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
  • Route switch processor 720
    !!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
    • RSP720-3C-GE
    • RSP720-3CXL-GE

!!! Note: the supervisor engine 2 is not longer supported in the Cisco7606-S router.

Power supplies and power entry modules

Both, the Cisco7606 and the Cisco7606-S router have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.

Supported power supplies in the Cisco7606 router

  • 1900 watt AC-input power supply
    • PWR-1900-AC/6

!!! Note: the power entry module PEM-20A-AC is needed when using a PWR-1900-AC/6. You need one PEM-20A-AC per PWR-1900-AC/6.
The power entry modules are installed on the front of the chassis on the very top.

  • 1900 watt DC-input power supply
    • PWR-1900-DC

!!! Note: the power entry module PEM-DC is needed when using a PWR-1900-DC. You need one PEM-DC per PWR-1900-DC.
The power entry modules are installed on the front of the chassis on the very top.

  • 2700 watt AC-input power supply
    • PWR-2700-AC

No power entry module is needed when using a PWR-2700-AC

  • 2700 watt DC-input power supply
    • PWR-2700-DC

No power entry module is needed when using a PWR-2700-DC

Supported power supplies in the Cisco7606-S router

  • 2700 watt AC-input power supply
    • PWR-2700-AC

No power entry module is needed when using a PWR-2700-AC

  • 2700 watt DC-input power supply
    • PWR-2700-DC

No power entry module is needed when using a PWR-2700-DC

Fan trays

Supported fan trays in the Cisco7606 router

  • standard fan module
    • WS-C6K-6SLOT-FAN
  • high speed fan module
    • FAN-MOD-6HS

!!! Note: supervisor engine 720 configurations require the FAN-MOD-6HS. WS-C6K-6SLOT-FAN will only work in supervisor engine 2 configurations.

Supported fan trays in the Cisco7606-S router

  • high speed fan module
    • FAN-MOD-6SHS

!!! Note: As a result of the sup 32 being the minimum required supervisor engine for the Cisco7606-S, no standard fan tray is supported in any cisco7606-S configuration. Both high speed fans, the FAN-MOD-6SHS and the FAN-MOD-6HS will work in the Cisco7606-S. With the FAN-MOD-6SHS being white, the colour would be the only difference.