Difference between revisions of "Stacking"

From NesevoWiki
Jump to navigationJump to search
 
(13 intermediate revisions by 3 users not shown)
Line 1: Line 1:
== 1. Definition==
+
== Definition==
You can connect several Switches over a special Port logical together. So you have following pros:
+
You can connect several Switches over a special Port logically together, which gives you the following opportunities:
* One big Switch with a lots of Port
+
* One big Switch with a lots of Ports
 
* One logical Switch
 
* One logical Switch
* You must only manage one switch
+
* You only have to manage one switch
 
* Minimal latency between the devices
 
* Minimal latency between the devices
 
Cisco has three difference techniques, FlexStack, StackWise and GigaStack <br/>
 
Cisco has three difference techniques, FlexStack, StackWise and GigaStack <br/>
 
!!!'''Note:''' It works only between the same series!!!
 
!!!'''Note:''' It works only between the same series!!!
== 2. Diiference between FlexStack and StackWise==
+
 
 +
== the difference between FlexStack and StackWise==
 
{| border = "1"
 
{| border = "1"
 
||  
 
||  
Line 66: Line 67:
 
|-
 
|-
 
|}
 
|}
== 3. Supported Switches==
 
  
=== 3.1 FlexStack===
+
==Supported Switches==
  
==== 3.1.1 Catalyst 2960 Series====
+
===FlexStack===
 +
 
 +
====Catalyst 2960 Series====
 
* WS-C2960PD-8TT-L
 
* WS-C2960PD-8TT-L
 
* WS-C2960-8TC-L
 
* WS-C2960-8TC-L
* WS-C2960-24TT-L
+
* [http://www.nesevo.com/ws-c2960-24tt-l.html WS-C2960-24TT-L]
 
* WS-C2960-48TT-L
 
* WS-C2960-48TT-L
 
* WS-C2960-24LT-L
 
* WS-C2960-24LT-L
Line 79: Line 81:
 
* WS-C2960-48PST-L
 
* WS-C2960-48PST-L
 
* WS-C2960-48TC-L
 
* WS-C2960-48TC-L
* WS-C2960G-8TC-L
+
* [http://www.nesevo.com/ws-c2960-48tc-l.html WS-C2960G-8TC-L]
* WS-C2960G-24TC-L
+
* [http://www.nesevo.com/ws-c2960g-24tc-l.html WS-C2960G-24TC-L]
* WS-C2960G-48TC-L
+
* [http://www.nesevo.com/ws-c2960g-48tc-l.html WS-C2960G-48TC-L]
  
==== 3.1.2 2960-S Series====
+
====Catalyst 2960-S Series====
 
* WS-C2960S-48FPD-L
 
* WS-C2960S-48FPD-L
 
* WS-C2960S-48LPD-L
 
* WS-C2960S-48LPD-L
Line 109: Line 111:
 
!!! '''Note:''' You need the '''C2960S-STACK''' Module for the Catalyst 2960 and Catalyst 2960-S series!!!
 
!!! '''Note:''' You need the '''C2960S-STACK''' Module for the Catalyst 2960 and Catalyst 2960-S series!!!
  
==== 3.1.3 Cables====
+
====Cables====
 
* CAB-STK-E-0.5M=
 
* CAB-STK-E-0.5M=
 
* CAB-STK-E-1M=
 
* CAB-STK-E-1M=
Line 115: Line 117:
  
  
===3.2 StackWise===
+
===StackWise===
==== 3.2.1 3560 Series====
+
====Catalyst 3560 Series====
 
* WS-C3560-8PC-S
 
* WS-C3560-8PC-S
 
* WS-C3560-12PC-S
 
* WS-C3560-12PC-S
* WS-C3560-24TS-S
+
* [http://www.nesevo.com/ws-c3560-24ts-s.html WS-C3560-24TS-S]
* WS-C3560-24TS-E
+
* [http://www.nesevo.com/ws-c3560-24ts-e-rf.html WS-C3560-24TS-E]
 
* WS-C3560-48TS-S
 
* WS-C3560-48TS-S
 
* WS-C3560-48TS-E
 
* WS-C3560-48TS-E
* WS-C3560-24PS-S
+
* [http://www.nesevo.com/ws-c3560g-24ps-s-rf.html WS-C3560-24PS-S]
 
* WS-C3560-24PS-E
 
* WS-C3560-24PS-E
 
* WS-C3560-48PS-S
 
* WS-C3560-48PS-S
 
* WS-C3560-48PS-E
 
* WS-C3560-48PS-E
* WS-C3560G-24TS-S
+
* [http://www.nesevo.com/ws-c3560g-24ts-s-rf.html WS-C3560G-24TS-S]
* WS-C3560G-24TS-E
+
* [http://www.nesevo.com/ws-c3560g-24ts-e.html WS-C3560G-24TS-E]
 
* WS-C3560G-48TS-S
 
* WS-C3560G-48TS-S
 
* WS-C3560G-48TS-E
 
* WS-C3560G-48TS-E
Line 136: Line 138:
 
* WS-C3560G-48PS-E
 
* WS-C3560G-48PS-E
  
====3.2.2 3750 Series====
+
====Catalyst 3750 Series====
 
* WC-C2948G-GE-TX
 
* WC-C2948G-GE-TX
 
* WS-C3750G-24TS-E1U
 
* WS-C3750G-24TS-E1U
* WS-C3750G-24TS-S1U
+
* [http://www.nesevo.com/ws-c3750g-24ts-s1u-rf.html WS-C3750G-24TS-S1U]
 
* WS-C3750G-24TS-E
 
* WS-C3750G-24TS-E
 
* WS-C3750G-24TS-S
 
* WS-C3750G-24TS-S
 
* WS-C3750G-24WS-S25
 
* WS-C3750G-24WS-S25
* WS-C3750G-24WS-S50
+
* [http://www.nesevo.com/ws-c3750g-24ws-s50-rf.html WS-C3750G-24WS-S50]
 
* WS-C3750G-24T-E
 
* WS-C3750G-24T-E
* WS-C3750G-24T-S
+
* [http://www.nesevo.com/ws-c3750g-24t-s.html WS-C3750G-24T-S]
 
* WS-C3750G-12S-E
 
* WS-C3750G-12S-E
* WS-C3750G-12S-S
+
* [http://www.nesevo.com/ws-c3750g-12s-s.html WS-C3750G-12S-S]
 
* WS-C3750G-12S-SD
 
* WS-C3750G-12S-SD
 
* WS-C3750G-16TD-E
 
* WS-C3750G-16TD-E
* WS-C3750G-16TD-S
+
* [http://www.nesevo.com/ws-c3750g-16td-s-rf.html WS-C3750G-16TD-S]
 
* WS-C3750G-24PS-E
 
* WS-C3750G-24PS-E
 
* WS-C3750G-24PS-S
 
* WS-C3750G-24PS-S
Line 158: Line 160:
 
* WS-C3750G-48PS-S
 
* WS-C3750G-48PS-S
 
* WS-C3750-48PS-E
 
* WS-C3750-48PS-E
* WS-C3750-48PS-S
+
* [http://www.nesevo.com/ws-c3750-48ps-s-rf.html WS-C3750-48PS-S]
 
* WS-C3750-48TS-E
 
* WS-C3750-48TS-E
 
* WS-C3750-48TS-S
 
* WS-C3750-48TS-S
 
* WS-C3750-24PS-E
 
* WS-C3750-24PS-E
* WS-C3750-24PS-S
+
* [http://www.nesevo.com/ws-c3750-24ps-s-rf.html WS-C3750-24PS-S]
 
* WS-C3750-24TS-E
 
* WS-C3750-24TS-E
* WS-C3750-24TS-S
+
* [http://www.nesevo.com/ws-c3750-24ts-s.html WS-C3750-24TS-S]
 
* WS-C3750-24FS-S
 
* WS-C3750-24FS-S
  
====3.2.3 3750-E Series====
+
====Catalyst 3750-E Series====
* WS-C3750E-24TD-S
+
* [http://www.nesevo.com/ws-c3750e-24td-s-rf.html WS-C3750E-24TD-S]
 
* WS-C3750E-24TD-SD
 
* WS-C3750E-24TD-SD
 
* WS-C3750E-24TD-E
 
* WS-C3750E-24TD-E
Line 181: Line 183:
 
* WS-C3750E-48PD-EF
 
* WS-C3750E-48PD-EF
  
====3.2.4 Cables====
+
====Cables====
 
* CAB-STACK-50CM=
 
* CAB-STACK-50CM=
 
* CAB-STACK-1M=
 
* CAB-STACK-1M=
 
* CAB-STACK-3M=
 
* CAB-STACK-3M=
  
===3.3 GigaStack===
+
===GigaStack===
  
==== 3.3.1 3550 Series====
+
====Catalyst 3550 Series====
* WS-C3550-12G
+
* [http://www.nesevo.com/ws-c3550-12g.html WS-C3550-12G]
* WS-C3550-12T
+
* [http://www.nesevo.com/ws-c3550-12t-rf.html WS-C3550-12T]
* WS-C3550-24-SMI
+
* W[http://www.nesevo.com/ws-c3550-24-smi-rf.html WS-C3550-24-SMI]
* WS-C3550-24PWR-SMI
+
* [http://www.nesevo.com/ws-c3550-24pwr-smi-rf.html WS-C3550-24PWR-SMI]
 
* WS-C3550-24-DC-SMI
 
* WS-C3550-24-DC-SMI
 
* WS-C3550-24-FX-SMI
 
* WS-C3550-24-FX-SMI
 
* WS-C3550-24-EMI
 
* WS-C3550-24-EMI
 
* WS-C3550-24PWR-EMI
 
* WS-C3550-24PWR-EMI
* WS-C3550-48-SMI
+
* [http://www.nesevo.com WS-C3550-48-SMI]
 
* WS-C3550-48-EMI
 
* WS-C3550-48-EMI
  
====3.3.2 2950 / 2950GSeries====
+
====Catalyst 2950 / 2950G Series====
* WS-C2950G-48-EI
+
* [http://www.nesevo.com/ws-c2950g-48-ei-rf.html WS-C2950G-48-EI]
* WS-C2950G-24-EI
+
* [http://www.nesevo.com/ws-c2950g-24-ei-rf.html WS-C2950G-24-EI]
 
* WS-C2950G-24-EI-DC
 
* WS-C2950G-24-EI-DC
 
* WS-C2950G-12-EI
 
* WS-C2950G-12-EI
* WS-C2950T-24
+
* [http://www.nesevo.com/ws-c2950t-24-rf.html WS-C2950T-24]
* WS-C2950C-24
+
* [http://www.nesevo.com/ws-c2950c-24-rf.html WS-C2950C-24]
 
* WS-C2950ST-24-LRE
 
* WS-C2950ST-24-LRE
* WS-C2950ST-8-LRE
+
* [http://www.nesevo.com/ws-c2950st-8-lre-rf.html WS-C2950ST-8-LRE]
* WS-C2950-12
+
* [http://www.nesevo.com/ws-c2950-12-rf.html WS-C2950-12]
* WS-C2950-24
+
* [http://www.nesevo.com/ws-c2950-24-rf.html WS-C2950-24]
 
* WS-C2950SX-24
 
* WS-C2950SX-24
 
* WS-C2950T-48-SI
 
* WS-C2950T-48-SI
 
* WS-C2950SX-48-SI
 
* WS-C2950SX-48-SI
  
====3.3.3 2900-XL Series====
+
====Catalyst 2900-XL Series====
 
* WS-C2912MF-XL
 
* WS-C2912MF-XL
 
* WS-C2924M-XL
 
* WS-C2924M-XL
  
====3.3.4 3500-XL Series====
+
====Catalyst 3500-XL Series====
 
* WS-C3508G-XL
 
* WS-C3508G-XL
 
* WS-C3512G-XL
 
* WS-C3512G-XL
Line 225: Line 227:
 
* WS-C3548G-XL
 
* WS-C3548G-XL
  
!!!'''Note:''' You need the '''GigaStack GBIC'''to connect to the other!!!
+
!!!'''Note:''' You need the '''GigaStack GBIC'''to connect one to the other!!!

Latest revision as of 09:44, 19 April 2012

Definition

You can connect several Switches over a special Port logically together, which gives you the following opportunities:

  • One big Switch with a lots of Ports
  • One logical Switch
  • You only have to manage one switch
  • Minimal latency between the devices

Cisco has three difference techniques, FlexStack, StackWise and GigaStack
!!!Note: It works only between the same series!!!

the difference between FlexStack and StackWise

Cisco Catalyst 2960-S Stacking Cisco Catalyst 3750-X StackWise
Device limit 4 units 9 units
Stack bandwidth 10G/20G 32G/64G
Architecture Hardware drop table Ring (destination stripping)
Dynamic ring load balancing No Yes
Stack convergence 1-2 seconds Few milliseconds
Stack quality of service (QoS) Applied hop by hop Applied on ingress
Management Single IP address, SNMP, syslog Single IP address, SNMP, syslog
Configuration Single config and CLI, auto image and config update Single config and CLI, auto image and config update
Show and debug commands Unified Unified
Single forwarding and control plane Synchronize Address Resolution Protocol (ARP), MAC address, Internet Group Management Protocol (IGMP), VLAN tables Synchronize Address Resolution Protocol (ARP), MAC address, Internet Group Management Protocol (IGMP), VLAN tables, routing tables
Cross-stack features Yes Yes
Single bridge-ID Yes Yes
Redundancy Stack master 1:N redundancy Stack master 1:N redundancy

Supported Switches

FlexStack

Catalyst 2960 Series

Catalyst 2960-S Series

  • WS-C2960S-48FPD-L
  • WS-C2960S-48LPD-L
  • WS-C2960S-24PD-L
  • WS-C2960S-48TD-L
  • WS-C2960S-24TD-L
  • WS-C2960S-48FPS-L
  • WS-C2960S-48LPS-L
  • WS-C2960S-24PS-L
  • WS-C2960S-48TS-L
  • WS-C2960S-24TS-L
  • WS-C2960PD-8TT-L
  • WS-C2960-8TC-L
  • WS-C2960-24TT-L
  • WS-C2960-48TT-L
  • WS-C2960-24LT-L
  • WS-C2960-24PC-L
  • WS-C2960-48PST-L
  • WS-C2960-48TC-L
  • WS-C2960G-8TC-L
  • WS-C2960G-24TC-L
  • WS-C2960G-48TC-L


!!! Note: You need the C2960S-STACK Module for the Catalyst 2960 and Catalyst 2960-S series!!!

Cables

  • CAB-STK-E-0.5M=
  • CAB-STK-E-1M=
  • CAB-STK-E-3M=


StackWise

Catalyst 3560 Series

Catalyst 3750 Series

Catalyst 3750-E Series

  • WS-C3750E-24TD-S
  • WS-C3750E-24TD-SD
  • WS-C3750E-24TD-E
  • WS-C3750E-48TD-S
  • WS-C3750E-48TD-E
  • WS-C3750E-48TD-SD
  • WS-C3750E-24PD-S
  • WS-C3750E-24PD-E
  • WS-C3750E-48PD-S
  • WS-C3750E-48PD-E
  • WS-C3750E-48PD-SF
  • WS-C3750E-48PD-EF

Cables

  • CAB-STACK-50CM=
  • CAB-STACK-1M=
  • CAB-STACK-3M=

GigaStack

Catalyst 3550 Series

Catalyst 2950 / 2950G Series

Catalyst 2900-XL Series

  • WS-C2912MF-XL
  • WS-C2924M-XL

Catalyst 3500-XL Series

  • WS-C3508G-XL
  • WS-C3512G-XL
  • WS-C3524G-XL
  • WS-C3548G-XL

!!!Note: You need the GigaStack GBICto connect one to the other!!!