Difference between revisions of "Stacking"
From NesevoWiki
Jump to navigationJump to search (New page: == 1. Definition== You can connect several Switches over a special Port logical together. So you have following pros: * One big Switch with a lots of Port * One logical Switch * You must o...) |
|||
(14 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | == | + | == Definition== |
− | You can connect several Switches over a special Port | + | You can connect several Switches over a special Port logically together, which gives you the following opportunities: |
− | * One big Switch with a lots of | + | * One big Switch with a lots of Ports |
* One logical Switch | * One logical Switch | ||
− | * You | + | * You only have to manage one switch |
* Minimal latency between the devices | * Minimal latency between the devices | ||
Cisco has three difference techniques, FlexStack, StackWise and GigaStack <br/> | Cisco has three difference techniques, FlexStack, StackWise and GigaStack <br/> | ||
!!!'''Note:''' It works only between the same series!!! | !!!'''Note:''' It works only between the same series!!! | ||
− | == | + | |
+ | == the difference between FlexStack and StackWise== | ||
{| border = "1" | {| border = "1" | ||
|| | || | ||
Line 66: | Line 67: | ||
|- | |- | ||
|} | |} | ||
− | |||
− | == | + | ==Supported Switches== |
− | ==== | + | ===FlexStack=== |
+ | |||
+ | ====Catalyst 2960 Series==== | ||
* WS-C2960PD-8TT-L | * WS-C2960PD-8TT-L | ||
* WS-C2960-8TC-L | * WS-C2960-8TC-L | ||
− | * WS-C2960-24TT-L | + | * [http://www.nesevo.com/ws-c2960-24tt-l.html WS-C2960-24TT-L] |
* WS-C2960-48TT-L | * WS-C2960-48TT-L | ||
* WS-C2960-24LT-L | * WS-C2960-24LT-L | ||
Line 79: | Line 81: | ||
* WS-C2960-48PST-L | * WS-C2960-48PST-L | ||
* WS-C2960-48TC-L | * WS-C2960-48TC-L | ||
− | * WS-C2960G-8TC-L | + | * [http://www.nesevo.com/ws-c2960-48tc-l.html WS-C2960G-8TC-L] |
− | * WS-C2960G-24TC-L | + | * [http://www.nesevo.com/ws-c2960g-24tc-l.html WS-C2960G-24TC-L] |
− | * WS-C2960G-48TC-L | + | * [http://www.nesevo.com/ws-c2960g-48tc-l.html WS-C2960G-48TC-L] |
− | ==== | + | ====Catalyst 2960-S Series==== |
* WS-C2960S-48FPD-L | * WS-C2960S-48FPD-L | ||
* WS-C2960S-48LPD-L | * WS-C2960S-48LPD-L | ||
Line 109: | Line 111: | ||
!!! '''Note:''' You need the '''C2960S-STACK''' Module for the Catalyst 2960 and Catalyst 2960-S series!!! | !!! '''Note:''' You need the '''C2960S-STACK''' Module for the Catalyst 2960 and Catalyst 2960-S series!!! | ||
− | ==== | + | ====Cables==== |
* CAB-STK-E-0.5M= | * CAB-STK-E-0.5M= | ||
* CAB-STK-E-1M= | * CAB-STK-E-1M= | ||
Line 115: | Line 117: | ||
− | === | + | ===StackWise=== |
− | ==== | + | ====Catalyst 3560 Series==== |
* WS-C3560-8PC-S | * WS-C3560-8PC-S | ||
* WS-C3560-12PC-S | * WS-C3560-12PC-S | ||
− | * WS-C3560-24TS-S | + | * [http://www.nesevo.com/ws-c3560-24ts-s.html WS-C3560-24TS-S] |
− | * WS-C3560-24TS-E | + | * [http://www.nesevo.com/ws-c3560-24ts-e-rf.html WS-C3560-24TS-E] |
* WS-C3560-48TS-S | * WS-C3560-48TS-S | ||
* WS-C3560-48TS-E | * WS-C3560-48TS-E | ||
− | * WS-C3560-24PS-S | + | * [http://www.nesevo.com/ws-c3560g-24ps-s-rf.html WS-C3560-24PS-S] |
* WS-C3560-24PS-E | * WS-C3560-24PS-E | ||
* WS-C3560-48PS-S | * WS-C3560-48PS-S | ||
* WS-C3560-48PS-E | * WS-C3560-48PS-E | ||
− | * WS-C3560G-24TS-S | + | * [http://www.nesevo.com/ws-c3560g-24ts-s-rf.html WS-C3560G-24TS-S] |
− | * WS-C3560G-24TS-E | + | * [http://www.nesevo.com/ws-c3560g-24ts-e.html WS-C3560G-24TS-E] |
* WS-C3560G-48TS-S | * WS-C3560G-48TS-S | ||
* WS-C3560G-48TS-E | * WS-C3560G-48TS-E | ||
Line 136: | Line 138: | ||
* WS-C3560G-48PS-E | * WS-C3560G-48PS-E | ||
− | ==== | + | ====Catalyst 3750 Series==== |
* WC-C2948G-GE-TX | * WC-C2948G-GE-TX | ||
* WS-C3750G-24TS-E1U | * WS-C3750G-24TS-E1U | ||
− | * WS-C3750G-24TS-S1U | + | * [http://www.nesevo.com/ws-c3750g-24ts-s1u-rf.html WS-C3750G-24TS-S1U] |
* WS-C3750G-24TS-E | * WS-C3750G-24TS-E | ||
* WS-C3750G-24TS-S | * WS-C3750G-24TS-S | ||
* WS-C3750G-24WS-S25 | * WS-C3750G-24WS-S25 | ||
− | * WS-C3750G-24WS-S50 | + | * [http://www.nesevo.com/ws-c3750g-24ws-s50-rf.html WS-C3750G-24WS-S50] |
* WS-C3750G-24T-E | * WS-C3750G-24T-E | ||
− | * WS-C3750G-24T-S | + | * [http://www.nesevo.com/ws-c3750g-24t-s.html WS-C3750G-24T-S] |
* WS-C3750G-12S-E | * WS-C3750G-12S-E | ||
− | * WS-C3750G-12S-S | + | * [http://www.nesevo.com/ws-c3750g-12s-s.html WS-C3750G-12S-S] |
* WS-C3750G-12S-SD | * WS-C3750G-12S-SD | ||
* WS-C3750G-16TD-E | * WS-C3750G-16TD-E | ||
− | * WS-C3750G-16TD-S | + | * [http://www.nesevo.com/ws-c3750g-16td-s-rf.html WS-C3750G-16TD-S] |
* WS-C3750G-24PS-E | * WS-C3750G-24PS-E | ||
* WS-C3750G-24PS-S | * WS-C3750G-24PS-S | ||
Line 158: | Line 160: | ||
* WS-C3750G-48PS-S | * WS-C3750G-48PS-S | ||
* WS-C3750-48PS-E | * WS-C3750-48PS-E | ||
− | * WS-C3750-48PS-S | + | * [http://www.nesevo.com/ws-c3750-48ps-s-rf.html WS-C3750-48PS-S] |
* WS-C3750-48TS-E | * WS-C3750-48TS-E | ||
* WS-C3750-48TS-S | * WS-C3750-48TS-S | ||
* WS-C3750-24PS-E | * WS-C3750-24PS-E | ||
− | * WS-C3750-24PS-S | + | * [http://www.nesevo.com/ws-c3750-24ps-s-rf.html WS-C3750-24PS-S] |
* WS-C3750-24TS-E | * WS-C3750-24TS-E | ||
− | * WS-C3750-24TS-S | + | * [http://www.nesevo.com/ws-c3750-24ts-s.html WS-C3750-24TS-S] |
* WS-C3750-24FS-S | * WS-C3750-24FS-S | ||
− | ==== | + | ====Catalyst 3750-E Series==== |
− | * WS-C3750E-24TD-S | + | * [http://www.nesevo.com/ws-c3750e-24td-s-rf.html WS-C3750E-24TD-S] |
* WS-C3750E-24TD-SD | * WS-C3750E-24TD-SD | ||
* WS-C3750E-24TD-E | * WS-C3750E-24TD-E | ||
Line 181: | Line 183: | ||
* WS-C3750E-48PD-EF | * WS-C3750E-48PD-EF | ||
− | ==== | + | ====Cables==== |
* CAB-STACK-50CM= | * CAB-STACK-50CM= | ||
* CAB-STACK-1M= | * CAB-STACK-1M= | ||
* CAB-STACK-3M= | * CAB-STACK-3M= | ||
− | === | + | ===GigaStack=== |
− | ==== | + | ====Catalyst 3550 Series==== |
− | * WS-C3550-12G | + | * [http://www.nesevo.com/ws-c3550-12g.html WS-C3550-12G] |
− | * WS-C3550-12T | + | * [http://www.nesevo.com/ws-c3550-12t-rf.html WS-C3550-12T] |
− | * WS-C3550-24-SMI | + | * W[http://www.nesevo.com/ws-c3550-24-smi-rf.html WS-C3550-24-SMI] |
− | * WS-C3550-24PWR-SMI | + | * [http://www.nesevo.com/ws-c3550-24pwr-smi-rf.html WS-C3550-24PWR-SMI] |
* WS-C3550-24-DC-SMI | * WS-C3550-24-DC-SMI | ||
* WS-C3550-24-FX-SMI | * WS-C3550-24-FX-SMI | ||
* WS-C3550-24-EMI | * WS-C3550-24-EMI | ||
* WS-C3550-24PWR-EMI | * WS-C3550-24PWR-EMI | ||
− | * WS-C3550-48-SMI | + | * [http://www.nesevo.com WS-C3550-48-SMI] |
* WS-C3550-48-EMI | * WS-C3550-48-EMI | ||
− | ==== | + | ====Catalyst 2950 / 2950G Series==== |
− | * WS-C2950G-48-EI | + | * [http://www.nesevo.com/ws-c2950g-48-ei-rf.html WS-C2950G-48-EI] |
− | * WS-C2950G-24-EI | + | * [http://www.nesevo.com/ws-c2950g-24-ei-rf.html WS-C2950G-24-EI] |
* WS-C2950G-24-EI-DC | * WS-C2950G-24-EI-DC | ||
* WS-C2950G-12-EI | * WS-C2950G-12-EI | ||
− | * WS-C2950T-24 | + | * [http://www.nesevo.com/ws-c2950t-24-rf.html WS-C2950T-24] |
− | * WS-C2950C-24 | + | * [http://www.nesevo.com/ws-c2950c-24-rf.html WS-C2950C-24] |
* WS-C2950ST-24-LRE | * WS-C2950ST-24-LRE | ||
− | * WS-C2950ST-8-LRE | + | * [http://www.nesevo.com/ws-c2950st-8-lre-rf.html WS-C2950ST-8-LRE] |
− | * WS-C2950-12 | + | * [http://www.nesevo.com/ws-c2950-12-rf.html WS-C2950-12] |
− | * WS-C2950-24 | + | * [http://www.nesevo.com/ws-c2950-24-rf.html WS-C2950-24] |
* WS-C2950SX-24 | * WS-C2950SX-24 | ||
* WS-C2950T-48-SI | * WS-C2950T-48-SI | ||
* WS-C2950SX-48-SI | * WS-C2950SX-48-SI | ||
− | ==== | + | ====Catalyst 2900-XL Series==== |
* WS-C2912MF-XL | * WS-C2912MF-XL | ||
* WS-C2924M-XL | * WS-C2924M-XL | ||
− | ==== | + | ====Catalyst 3500-XL Series==== |
* WS-C3508G-XL | * WS-C3508G-XL | ||
* WS-C3512G-XL | * WS-C3512G-XL | ||
Line 225: | Line 227: | ||
* WS-C3548G-XL | * WS-C3548G-XL | ||
− | !!!'''Note:''' You need the '''GigaStack GBIC'''to connect to the other!!! | + | !!!'''Note:''' You need the '''GigaStack GBIC'''to connect one to the other!!! |
Latest revision as of 09:44, 19 April 2012
Definition
You can connect several Switches over a special Port logically together, which gives you the following opportunities:
- One big Switch with a lots of Ports
- One logical Switch
- You only have to manage one switch
- Minimal latency between the devices
Cisco has three difference techniques, FlexStack, StackWise and GigaStack
!!!Note: It works only between the same series!!!
the difference between FlexStack and StackWise
Cisco Catalyst 2960-S Stacking | Cisco Catalyst 3750-X StackWise | |
Device limit | 4 units | 9 units |
Stack bandwidth | 10G/20G | 32G/64G |
Architecture | Hardware drop table | Ring (destination stripping) |
Dynamic ring load balancing | No | Yes |
Stack convergence | 1-2 seconds | Few milliseconds |
Stack quality of service (QoS) | Applied hop by hop | Applied on ingress |
Management | Single IP address, SNMP, syslog | Single IP address, SNMP, syslog |
Configuration | Single config and CLI, auto image and config update | Single config and CLI, auto image and config update |
Show and debug commands | Unified | Unified |
Single forwarding and control plane | Synchronize Address Resolution Protocol (ARP), MAC address, Internet Group Management Protocol (IGMP), VLAN tables | Synchronize Address Resolution Protocol (ARP), MAC address, Internet Group Management Protocol (IGMP), VLAN tables, routing tables |
Cross-stack features | Yes | Yes |
Single bridge-ID | Yes | Yes |
Redundancy | Stack master 1:N redundancy | Stack master 1:N redundancy |
Supported Switches
FlexStack
Catalyst 2960 Series
- WS-C2960PD-8TT-L
- WS-C2960-8TC-L
- WS-C2960-24TT-L
- WS-C2960-48TT-L
- WS-C2960-24LT-L
- WS-C2960-24PC-L
- WS-C2960-48PST-L
- WS-C2960-48TC-L
- WS-C2960G-8TC-L
- WS-C2960G-24TC-L
- WS-C2960G-48TC-L
Catalyst 2960-S Series
- WS-C2960S-48FPD-L
- WS-C2960S-48LPD-L
- WS-C2960S-24PD-L
- WS-C2960S-48TD-L
- WS-C2960S-24TD-L
- WS-C2960S-48FPS-L
- WS-C2960S-48LPS-L
- WS-C2960S-24PS-L
- WS-C2960S-48TS-L
- WS-C2960S-24TS-L
- WS-C2960PD-8TT-L
- WS-C2960-8TC-L
- WS-C2960-24TT-L
- WS-C2960-48TT-L
- WS-C2960-24LT-L
- WS-C2960-24PC-L
- WS-C2960-48PST-L
- WS-C2960-48TC-L
- WS-C2960G-8TC-L
- WS-C2960G-24TC-L
- WS-C2960G-48TC-L
!!! Note: You need the C2960S-STACK Module for the Catalyst 2960 and Catalyst 2960-S series!!!
Cables
- CAB-STK-E-0.5M=
- CAB-STK-E-1M=
- CAB-STK-E-3M=
StackWise
Catalyst 3560 Series
- WS-C3560-8PC-S
- WS-C3560-12PC-S
- WS-C3560-24TS-S
- WS-C3560-24TS-E
- WS-C3560-48TS-S
- WS-C3560-48TS-E
- WS-C3560-24PS-S
- WS-C3560-24PS-E
- WS-C3560-48PS-S
- WS-C3560-48PS-E
- WS-C3560G-24TS-S
- WS-C3560G-24TS-E
- WS-C3560G-48TS-S
- WS-C3560G-48TS-E
- WS-C3560G-24PS-S
- WS-C3560G-24PS-E
- WS-C3560G-48PS-S
- WS-C3560G-48PS-E
Catalyst 3750 Series
- WC-C2948G-GE-TX
- WS-C3750G-24TS-E1U
- WS-C3750G-24TS-S1U
- WS-C3750G-24TS-E
- WS-C3750G-24TS-S
- WS-C3750G-24WS-S25
- WS-C3750G-24WS-S50
- WS-C3750G-24T-E
- WS-C3750G-24T-S
- WS-C3750G-12S-E
- WS-C3750G-12S-S
- WS-C3750G-12S-SD
- WS-C3750G-16TD-E
- WS-C3750G-16TD-S
- WS-C3750G-24PS-E
- WS-C3750G-24PS-S
- WS-C3750G-48TS-E
- WS-C3750G-48TS-S
- WS-C3750G-48PS-E
- WS-C3750G-48PS-S
- WS-C3750-48PS-E
- WS-C3750-48PS-S
- WS-C3750-48TS-E
- WS-C3750-48TS-S
- WS-C3750-24PS-E
- WS-C3750-24PS-S
- WS-C3750-24TS-E
- WS-C3750-24TS-S
- WS-C3750-24FS-S
Catalyst 3750-E Series
- WS-C3750E-24TD-S
- WS-C3750E-24TD-SD
- WS-C3750E-24TD-E
- WS-C3750E-48TD-S
- WS-C3750E-48TD-E
- WS-C3750E-48TD-SD
- WS-C3750E-24PD-S
- WS-C3750E-24PD-E
- WS-C3750E-48PD-S
- WS-C3750E-48PD-E
- WS-C3750E-48PD-SF
- WS-C3750E-48PD-EF
Cables
- CAB-STACK-50CM=
- CAB-STACK-1M=
- CAB-STACK-3M=
GigaStack
Catalyst 3550 Series
- WS-C3550-12G
- WS-C3550-12T
- WWS-C3550-24-SMI
- WS-C3550-24PWR-SMI
- WS-C3550-24-DC-SMI
- WS-C3550-24-FX-SMI
- WS-C3550-24-EMI
- WS-C3550-24PWR-EMI
- WS-C3550-48-SMI
- WS-C3550-48-EMI
Catalyst 2950 / 2950G Series
- WS-C2950G-48-EI
- WS-C2950G-24-EI
- WS-C2950G-24-EI-DC
- WS-C2950G-12-EI
- WS-C2950T-24
- WS-C2950C-24
- WS-C2950ST-24-LRE
- WS-C2950ST-8-LRE
- WS-C2950-12
- WS-C2950-24
- WS-C2950SX-24
- WS-C2950T-48-SI
- WS-C2950SX-48-SI
Catalyst 2900-XL Series
- WS-C2912MF-XL
- WS-C2924M-XL
Catalyst 3500-XL Series
- WS-C3508G-XL
- WS-C3512G-XL
- WS-C3524G-XL
- WS-C3548G-XL
!!!Note: You need the GigaStack GBICto connect one to the other!!!