Difference between revisions of "Cisco7603 and Cisco7603-S routers"
(27 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | '''NOT supported hardware in cisco7603 chassis'''<br/> | ||
+ | –WS-X6704-10GE—4-port 10-Gigabit Ethernet XENPAK <br/> | ||
+ | –WS-X6748-SFP—48-port Gigabit Ethernet SFP <br/> | ||
+ | –WS-X6724-SFP—24-port Gigabit Ethernet SFP <br/> | ||
+ | –WS-X6816-GBIC—16-port Gigabit Ethernet GBIC <br/> | ||
+ | –WS-X6748-GE-TX—48-port 10/100/1000 RJ-45<br/> | ||
+ | '''The above cards are supported in the cisco7603-S chassis''' | ||
+ | |||
==Supervisor engines== | ==Supervisor engines== | ||
− | Both, the Cisco7603 and the Cisco7603-S router have three horizontal slots being numbered from top to bottom.<br/> | + | [[image:Cisco7603 front.jpg|framed|Cisco7603 front]] |
+ | [[image:Cisco7603 rear.jpg|framed|Cisco7603 rear]] | ||
+ | [[image:Cisco7603-S front.jpg|framed|Cisco7603-S front]] | ||
+ | [[image:Cisco7603-S rear.jpg|framed|Cisco7603-S rear]] | ||
+ | Both, the Cisco7603 and the Cisco7603-S router have three horizontal slots being numbered from top to bottom and measure 4 rack units (4 RU).<br/> | ||
While slot 1 is reserved for the supervisor engine, slot 2 can contain an optional redundant supervisor engine.<br/> | While slot 1 is reserved for the supervisor engine, slot 2 can contain an optional redundant supervisor engine.<br/> | ||
− | ''When installing a redundant supervisor engine, both supervisor engines must be identical.''<br/> | + | ''!!! Note: When installing a redundant supervisor engine, both supervisor engines must be identical.''<br/> |
− | ''The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by''<br/> | + | ''!!! Note: The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by.''<br/> |
+ | If a redundant supervisor engine is not required, slot two can be equipped with any supported cisco7600 series / catalyst 6500 series module.<br/> | ||
'''Supported supervisor engines in the Cisco7603 router'''<br/> | '''Supported supervisor engines in the Cisco7603 router'''<br/> | ||
*Supervisor engine 2<br/> | *Supervisor engine 2<br/> | ||
− | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-PFC2]]<br/> | |
− | **WS-X6K-S2-PFC2<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-MSFC2]] <br/> |
− | **WS-X6K-S2-MSFC2<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2U-MSFC2]] <br/> |
− | **WS-X6K-S2U-MSFC2<br/> | ||
*Supervisor engine 720<br/> | *Supervisor engine 720<br/> | ||
− | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/> | |
− | **WS-SUP720<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/> |
− | **WS-SUP720-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]] <br/> |
− | **WS-SUP720-3BXL<br/> | ||
− | ''While being supported in the WS-C6503 and WS-C6503-E chassis, the supervisor engine 32 is not supported in the ciso7603 router'' | + | ''!!! Note: While being supported in the WS-C6503 and WS-C6503-E chassis, the supervisor engine 32 is not supported in the ciso7603 router'' |
'''Supported supervisor engines in the Cisco7603-S router'''<br/> | '''Supported supervisor engines in the Cisco7603-S router'''<br/> | ||
*Supervisor engine 32<br/> | *Supervisor engine 32<br/> | ||
− | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B]] <br/> | |
− | **WS-SUP32-GE-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]] <br/> |
− | **WS-SUP32-10GE-3B<br/> | ||
*Supervisor engine 720<br/> | *Supervisor engine 720<br/> | ||
− | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/> | |
− | **WS-SUP720<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/> |
− | **WS-SUP720-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]]<br/> |
− | **WS-SUP720-3BXL<br/> | ||
*Route switch processor 720<br/> | *Route switch processor 720<br/> | ||
− | |||
**RSP720-3C-GE<br/> | **RSP720-3C-GE<br/> | ||
**RSP720-3CXL-GE<br/> | **RSP720-3CXL-GE<br/> | ||
− | ''the supervisor engine 2 is not longer supported in the Cisco7603-S router.''<br/> | + | ''!!! Note: the supervisor engine 2 is not longer supported in the Cisco7603-S router.''<br/> |
+ | |||
+ | ==Power supplies and power entry modules== | ||
+ | Both, the Cisco7603 and the Cisco7603-S router have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.<br/> | ||
+ | |||
+ | '''Supported spower supplies in the Cisco7603 router'''<br/> | ||
+ | *950 watt AC-input power supply<br/> | ||
+ | **PWR-950-AC<br/> | ||
+ | ''!!! Note: the power entry module '''PEM-15A-AC ''' is needed when using a PWR-950-AC. You need one '''PEM-15A-AC ''' per PWR-950-AC.<br/>'' | ||
+ | ''The power entry modules are installed on the front of the chassis on the very top.'' | ||
+ | |||
+ | *950 watt DC-input power supply<br/> | ||
+ | **PWR-950-DC<br/> | ||
+ | ''!!! Note: the power entry module '''PEM-DC/3''' is needed when using a PWR-950-DC. You need one '''PEM-DC/3''' per PWR-950-DC.<br/>'' | ||
+ | ''The power entry modules are installed on the front of the chassis on the very top.'' | ||
+ | |||
+ | *1400 watt AC-input power supply<br/> | ||
+ | **PWR-1400-AC<br/> | ||
+ | ''!!! Note: the power entry module '''PEM-20A-AC+''' is needed when using a PWR-1400-AC. You need one '''PEM-20A-AC+''' per PWR-1400-AC.<br/>'' | ||
+ | ''The power entry modules are installed on the front of the chassis on the very top.'' | ||
+ | |||
+ | '''Supported spower supplies in the Cisco7603-S router'''<br/> | ||
+ | *1500 watt DC-input power supply<br/> | ||
+ | **PWR-1500-DC<br/> | ||
+ | ''!!! Note: the power entry module '''PEM-1500W-DC/03S''' is needed when using a PWR-1500-DC. You need one '''PEM-1500W-DC/03S''' per PWR-1500-DC.<br/>'' | ||
+ | ''The power entry modules are installed on the front of the chassis on the very top.''<br/> | ||
+ | '''''There is no longer an AC power supply option for the Cisco7603-S router''''' | ||
+ | |||
+ | ==Fan trays== | ||
+ | |||
+ | '''Supported fan trays in the Cisco7603 router'''<br/> | ||
+ | *standard fan module<br/> | ||
+ | **FAN-MOD-3<br/> | ||
+ | *high speed fan module<br/> | ||
+ | **FAN-MOD-3HS<br/> | ||
+ | ''!!! Note: supervisor engine 720 configurations require the '''FAN-MOD-3HS'''. '''The FAN-MOD-3''' will only work in supervisor engine 2 configurations.''<br/> | ||
− | + | '''Supported fan trays in the Cisco7603-S router'''<br/> | |
+ | *high speed fan module<br/> | ||
+ | **FAN-MOD-3SHS<br/> | ||
+ | ''!!! Note: As a result of the sup 32 being the minimum required supervisor engine for the Cisco7603-S, no standard fan tray is supported in any cisco7603-S configuration. Both high speed fans, the FAN-MOD-3SHS and the FAN-MOD-3HS will work in the Cisco7603-S. With the FAN-MOD-3SHS being white, the colour would be the only difference.''<br/> |
Latest revision as of 13:47, 29 October 2010
NOT supported hardware in cisco7603 chassis
–WS-X6704-10GE—4-port 10-Gigabit Ethernet XENPAK
–WS-X6748-SFP—48-port Gigabit Ethernet SFP
–WS-X6724-SFP—24-port Gigabit Ethernet SFP
–WS-X6816-GBIC—16-port Gigabit Ethernet GBIC
–WS-X6748-GE-TX—48-port 10/100/1000 RJ-45
The above cards are supported in the cisco7603-S chassis
Supervisor engines
Both, the Cisco7603 and the Cisco7603-S router have three horizontal slots being numbered from top to bottom and measure 4 rack units (4 RU).
While slot 1 is reserved for the supervisor engine, slot 2 can contain an optional redundant supervisor engine.
!!! Note: When installing a redundant supervisor engine, both supervisor engines must be identical.
!!! Note: The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by.
If a redundant supervisor engine is not required, slot two can be equipped with any supported cisco7600 series / catalyst 6500 series module.
Supported supervisor engines in the Cisco7603 router
- Supervisor engine 2
- Supervisor engine 720
!!! Note: While being supported in the WS-C6503 and WS-C6503-E chassis, the supervisor engine 32 is not supported in the ciso7603 router
Supported supervisor engines in the Cisco7603-S router
- Supervisor engine 32
- Supervisor engine 720
- Route switch processor 720
- RSP720-3C-GE
- RSP720-3CXL-GE
- RSP720-3C-GE
!!! Note: the supervisor engine 2 is not longer supported in the Cisco7603-S router.
Power supplies and power entry modules
Both, the Cisco7603 and the Cisco7603-S router have two power supply slots on the back of the chassis, with the power supply 1 being installed on the bottom and the optional redundant power supply 2 being installed in the upper of the two slots.
Supported spower supplies in the Cisco7603 router
- 950 watt AC-input power supply
- PWR-950-AC
- PWR-950-AC
!!! Note: the power entry module PEM-15A-AC is needed when using a PWR-950-AC. You need one PEM-15A-AC per PWR-950-AC.
The power entry modules are installed on the front of the chassis on the very top.
- 950 watt DC-input power supply
- PWR-950-DC
- PWR-950-DC
!!! Note: the power entry module PEM-DC/3 is needed when using a PWR-950-DC. You need one PEM-DC/3 per PWR-950-DC.
The power entry modules are installed on the front of the chassis on the very top.
- 1400 watt AC-input power supply
- PWR-1400-AC
- PWR-1400-AC
!!! Note: the power entry module PEM-20A-AC+ is needed when using a PWR-1400-AC. You need one PEM-20A-AC+ per PWR-1400-AC.
The power entry modules are installed on the front of the chassis on the very top.
Supported spower supplies in the Cisco7603-S router
- 1500 watt DC-input power supply
- PWR-1500-DC
- PWR-1500-DC
!!! Note: the power entry module PEM-1500W-DC/03S is needed when using a PWR-1500-DC. You need one PEM-1500W-DC/03S per PWR-1500-DC.
The power entry modules are installed on the front of the chassis on the very top.
There is no longer an AC power supply option for the Cisco7603-S router
Fan trays
Supported fan trays in the Cisco7603 router
- standard fan module
- FAN-MOD-3
- FAN-MOD-3
- high speed fan module
- FAN-MOD-3HS
- FAN-MOD-3HS
!!! Note: supervisor engine 720 configurations require the FAN-MOD-3HS. The FAN-MOD-3 will only work in supervisor engine 2 configurations.
Supported fan trays in the Cisco7603-S router
- high speed fan module
- FAN-MOD-3SHS
- FAN-MOD-3SHS
!!! Note: As a result of the sup 32 being the minimum required supervisor engine for the Cisco7603-S, no standard fan tray is supported in any cisco7603-S configuration. Both high speed fans, the FAN-MOD-3SHS and the FAN-MOD-3HS will work in the Cisco7603-S. With the FAN-MOD-3SHS being white, the colour would be the only difference.