Difference between revisions of "Catalyst Express 500 Series"
From NesevoWiki
Jump to navigationJump to search| (7 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
{| border = "1" | {| border = "1" | ||
||'''Feature ''' | ||'''Feature ''' | ||
| − | |align="center"|''' | + | |align="center"|'''WS-CE500-24-TT''' |
| − | |align="center"|''' | + | |align="center"|'''WS-CE500-24LC''' |
| − | |align="center"|''' | + | |align="center"|'''WS-CE500-24PC''' |
| − | |align="center"|''' | + | |align="center"|'''WS-CE500G-12TC''' |
|- | |- | ||
||'''EOS''' | ||'''EOS''' | ||
| Line 18: | Line 18: | ||
|align="center"|1 RU | |align="center"|1 RU | ||
|- | |- | ||
| − | ||'''Switch Fabric ''' | + | ||'''[[Switch Fabric]] ''' |
|align="center"|8.8Gbps | |align="center"|8.8Gbps | ||
|align="center"| 8.8Gbps | |align="center"| 8.8Gbps | ||
| Line 24: | Line 24: | ||
|align="center"|24Gbps | |align="center"|24Gbps | ||
|- | |- | ||
| − | ||'''Forwarding Rate''' | + | ||'''[[Forwarding Rate]]''' |
|align="center"|6.6Mpps | |align="center"|6.6Mpps | ||
|align="center"|6.6Mpps | |align="center"|6.6Mpps | ||
| Line 72: | Line 72: | ||
|align="center"|No | |align="center"|No | ||
|- | |- | ||
| − | ||'''Max. MAC Addresses''' | + | ||'''[[Max. MAC Addresses]]''' |
|align="center"|8000 | |align="center"|8000 | ||
|align="center"|8000 | |align="center"|8000 | ||
| Line 156: | Line 156: | ||
|align="center"| 8 lb (3.7kg) | |align="center"| 8 lb (3.7kg) | ||
|- | |- | ||
| − | ||'''RPS Used ''' | + | ||'''[[RPS]] Used ''' |
|align="center"|No | |align="center"|No | ||
|align="center"|No | |align="center"|No | ||
| Line 162: | Line 162: | ||
|align="center"| No | |align="center"| No | ||
|- | |- | ||
| − | ||'''MTBF (Hours)''' | + | ||'''[[MTBF]] (Hours)''' |
|align="center"|308,482 | |align="center"|308,482 | ||
|align="center"|282,705 | |align="center"|282,705 | ||
| Line 169: | Line 169: | ||
|- | |- | ||
|} | |} | ||
| + | <br/><br/> | ||
| + | '''Notes:''' | ||
| + | <br/> | ||
| + | The 500-24LC and 500-24PC models can have either two 10/100/1000 or two SFP ports. The 500G-12TC model can have either four | ||
| + | 10/100/1000 or four SFP ports. The 500G-12TC model has a minimum of eight 10/100/1000 ports | ||
Latest revision as of 08:14, 2 October 2008
| Feature | WS-CE500-24-TT | WS-CE500-24LC | WS-CE500-24PC | WS-CE500G-12TC |
| EOS | No | No | No | No |
| Form Factor | 1 RU | 1 RU | 1 RU | 1 RU |
| Switch Fabric | 8.8Gbps | 8.8Gbps | 8.8Gbps | 24Gbps |
| Forwarding Rate | 6.6Mpps | 6.6Mpps | 6.6Mpps | 18Mpps |
| 10/100 Ports | 24 | 24 (4 PoE) | 24 (All PoE) | 0 |
| 10/100/1000 Ports (see note) | 2 | 2 | 2 | 12 |
| SFP GE Ports (see note) | 0 | 2 | 2 | 4 |
| VLAN Trunking | 802.1q only | 802.1q only | 802.1q only | 802.1q only |
| EtherChannel | All ports | All ports | All ports | All ports |
| Voice-VLAN's | Yes | Yes | Yes | Yes |
| Multi-VLAN Capable | No | No | No | No |
| Max. MAC Addresses | 8000 | 8000 | 8000 | 8000 |
| Max. MTU | 1,500 Bytes | 1,500 Bytes | 1,500 Bytes | 1,500 Bytes |
| Multicast | IGMP Snooping in hardware | IGMP Snooping in hardware | IGMP Snooping in hardware | IGMP Snooping in hardware |
| Ingress Policing | None | None | None | None |
| Queues per port | 4 | 4 | 4 | 4 |
| QoS Granularity | N/A | N/A | N/A | N/A |
| DSCP/CoS Remark. | Yes | Yes | Yes | Yes |
| Heat (W), Max. | 30 | 45 | 90 | 45 |
| Heat (BTU), Max. | 102 | 154 | 307 | 154 |
| Dimensions (H/W/D) | 1.73 x 17.5 x 9.9 in. (4.39 x 44.45 x 25.15 cm) | 1.73 x 17.5 x 9.9 in. (4.39 x 44.45 x 25.15 cm) | 1.73 x 17.5 x 14.4 in. (4.39 x 44.45 x 36.58 cm) | 1.73 x 17.5 x 9.9 in. (4.39 x 44.45 x 25.15 cm) |
| Operating Temp. | 32 to 113°F (0 to 45°C) | 33 to 113°F (0 to 45°C) | 34 to 113°F (0 to 45°C) | 35 to 113°F (0 to 45°C) |
| Storage Temp. | -13 to 158°F (-25 to 70°C) | -13 to 158°F (-25 to 70°C) | -13 to 158°F (-25 to 70°C) | -13 to 158°F (-25 to 70°C) |
| Relative Humidity | 10 to 85% (noncondensing) | 11 to 85% (noncondensing) | 12 to 85% (noncondensing) | 13 to 85% (noncondensing) |
| Weight | 8 lb (3.7kg) | 8 lb (3.7kg) | 12 lb (5.5kg) | 8 lb (3.7kg) |
| RPS Used | No | No | RPS-675 | No |
| MTBF (Hours) | 308,482 | 282,705 | 211,167 | 289,193 |
Notes:
The 500-24LC and 500-24PC models can have either two 10/100/1000 or two SFP ports. The 500G-12TC model can have either four
10/100/1000 or four SFP ports. The 500G-12TC model has a minimum of eight 10/100/1000 ports