Difference between revisions of "Catalyst 6000 Supervisors - Supervisor 720/32 Variants"

From NesevoWiki
Jump to navigationJump to search
(New page: {| border = "1" ||'''Feature''' |align="center"|'''MSFC''' |align="center"|'''MSFC 2''' |align="center"|'''MSFC 3''' |- ||'''Required Software''' |align="center"|5.3(1), 12.0(3)XE(Hybrid) ...)
 
Line 102: Line 102:
 
|}
 
|}
  
<br/><br/>
+
<br/>
'''Notes - MSFC:'''
+
'''Notes - Supervsior 720/32 Variants:'''
<br/><br/>
+
<br/>
MSFC/MSFC2 requires use of PFC/PFC2. FlexWan linecard requires a MSFC/MSFC2.
+
Maximum DRAM on the Sup720 is 1GB (not available as a spare) - only offered with the 3BXL upgrade.
<br/>
 
MSFC/MSFC2's are not addable to a Supervisor 1A-PFC after the fact (as a FRU) since risers are not included. MSFC/MSFC2's are only addable to Supervisor 1A's that previously had a MSFC/MSFC2.
 
<br/>
 
If the MSFC2 is doing full Internet routes and/or MPLS, 512Mb DRAM is required. MSFC (1) does not have enough DRAM to run full Internet routes.
 
<br/>
 
MSFC2's shipped prior to July 1, 2002 shipped with 16MB bootflash.
 
<br/>
 
Release 12.1(13)E includes support for 4,096 VLAN's, but it is not recommended to exceed 2,000.
 
<br/>
 
MSFC2 memory went to 256MB default on August 1, 2004 (previously was 128MB). 512MB is default for Sup2U orders after that same date (previously was 256MB)
 
<br/>
 
Cells depicted in light blue are unknown at this time, and will be filled in as details become available.
 

Revision as of 14:15, 29 September 2008

Feature MSFC MSFC 2 MSFC 3
Required Software 5.3(1), 12.0(3)XE(Hybrid) 12.1(2)E (Native) 5.4(2), 12.1(2)E (Hybrid) 12.1(8a)E (Native) 12.2(14)SX2 (Hybrid) 12.2(14)SX (Native)
Onboard Flash 16 MB 32 MB 64 MB
CPU 200MHz R5000 300MHz RM7000 600MHz
EOS February 28, 2002 No No
Default DRAM 64 MB 256MB (if ordered with Sup2) 512MB (if ordered with Sup2U) 512 MB (or 1GB, if with the 720-3BXL)
Maximum DRAM 128 MB 512 MB 1 GB
DRAM Slots 1 1 1
DRAM Type EDO DRAM ECC SDRAM ECC SDRAM
NVRAM 128 KB 512 KB 2 MB
High Speed Packet Memory 4 MB 8 MB
Maximum WAN Interfaces 384 800
Maximum Terminated VLANs 256 2000
WCCPv2 Performance 50.000cps 150.000cps Not Supported
IPv4, IPMC Switching 15.000.000pps 30.000.000pps 30.000.000pps
Fast Switch Performance 170.000pps 500.000pps 500.000pps
Dimensions 0.6 x 15.25 x 8 in. (1.52 x 38.74 x 20.32 cm) 0.093 x 15.62 x 7.9 in. (0.236 x 39.675 x 20.066 cm)
Operating Temperature 32 to 104° F (0 to 40° C) 32 to 104° F (0 to 40° C) 32 to 104° F (0 to 40° C)
Storage Temperature -40 to 167° F (-40 to 75° C) -40 to 167° F (-40 to 75° C) -40 to 167° F (-40 to 75° C)
Relative Humidity 10% to 90%, non-condensing 10% to 90%, non-condensing 10% to 90%, non-condensing


Notes - Supervsior 720/32 Variants:
Maximum DRAM on the Sup720 is 1GB (not available as a spare) - only offered with the 3BXL upgrade.