Difference between revisions of "Catalyst 5000 - Switching Fabric Only Supervisors"

From NesevoWiki
Jump to navigationJump to search
Line 1: Line 1:
Catalyst 5000 - Switching Fabric Only Supervisors
 
<br/><br/>
 
 
{| border = "1"
 
{| border = "1"
 +
||'''Feature '''
 +
|align="center"|'''Supervisor III '''
 +
|align="center"|'''Supervisor III F'''
 +
|align="center"|''' Supervisor III G'''
 +
|-
 +
||'''EOS Status '''
 +
|align="center"|July 30, 2003
 +
|align="center"| April 15, 2000
 +
|align="center"|July 30, 2003
 +
|-
 +
||'''Chassis Support'''
 +
|align="center"|All but 5002 with 155W Power
 +
|align="center"| All
 +
|align="center"|All
 +
|-
 +
||'''Redundant Supervisors'''
 +
|align="center"|Yes
 +
|align="center"|Yes
 +
|align="center"|Yes
 +
|-
 +
||'''Processor'''
 +
|align="center"|150MHz R4700 RISC
 +
|align="center"| IDT RISC (Similar to SupII)
 +
|align="center"|37.5MHz Motorola  MCF5102
 +
|-
 +
||'''Modular NFFC-II '''
 +
|align="center"|Yes (A and II-A)*
 +
|align="center"|Yes
 +
|align="center"| Integrated
 +
|-
 +
||'''Modular RSFC'''
 +
|align="center"| No
 +
|align="center"| No
 +
|align="center"|Yes
 +
|-
 +
||'''Fixed Uplinks'''
 +
|align="center"| None
 +
|align="center"|(2)1000BaseSX (2)1000BaseLX
 +
|align="center"|(2)GBIC
 +
|-
 +
||'''Modular Uplinks No No'''
 +
|align="center"|(2/4)100BaseTX, (2/4)100BaseFX, (2)1000BaseSX, (2)1000BaseLX
 +
|align="center"|No
 +
|align="center"|No
 
|-
 
|-
||Feature
+
||'''Backplane Connection'''
||Supervisor I
+
|align="center"|3.6 Gbps
||Supervisor II
+
|align="center"|3.6 Gbps
|| Supervisor IIG
+
|align="center"|3.6 Gbps
 
|-
 
|-
||Chassis Support
+
||'''PCMCIA Flash'''
|| 5000, 5002
+
|align="center"| Yes
||All
+
|align="center"| No
|| All
+
|align="center"|No
 
|-
 
|-
||Redundant Supervisors
+
||'''Default Flash'''
||No
+
|align="center"|8 MB
|| Yes
+
|align="center"|8 MB
|| Yes
+
|align="center"|8 MB
 
|-
 
|-
||Processor
+
||'''Default DRAM '''
||25MHz Motorola  MC68EC040
+
|align="center"|64 MB
||25MHz Motorola MC68EC040
+
|align="center"| 32 MB
||37.5MHz Motorola  MCF5102
+
|align="center"| 32 MB
 
|-
 
|-
||Modular NFFC-II
+
||'''NVRAM'''
||No
+
|align="center"|512 KB
||No
+
|align="center"|512 KB
|| Integrated
+
|align="center"|512 KB
 
|-
 
|-
||Modular RSFC
+
||'''Console Port'''
|| No
+
|align="center"|RJ-45
|| No
+
|align="center"|RJ-45
||Yes
+
|align="center"|RJ-45
 
|-
 
|-
||Fixed Uplinks
+
||'''Auxiliary Port'''
|| (2)100BaseTX (2)100BaseTX
+
|align="center"|RJ-45
||(2)100BaseFX (2)100BaseFX
+
|align="center"|RJ-45
||None
+
|align="center"|RJ-45
 
|-
 
|-
||Modular Uplinks
+
||'''FE Management Interface'''
||None
+
|align="center"|Yes
||None
+
|align="center"|Yes
||(4)100BaseTX (4)100BaseFX (2)1000BaseSX (2)1000BaseLX
+
|align="center"|Yes
 
|-
 
|-
||Backplane Connection
+
||'''EtherChannel on Uplinks FEC No No'''
||1.2 Gbps
+
|align="center"|FEC
||1.2 Gbps
+
|align="center"|No
||1.2 Gbps
+
|align="center"|No
 
|-
 
|-
||PCMCIA Flash
+
||'''Max # of MAC Addresses'''
||No
+
|align="center"|16000
||No
+
|align="center"|16000
||No
+
|align="center"|16000
 
|-
 
|-
||Default Flash
+
||'''Max VLANs'''
|| 4 MB
+
|align="center"|1024
||8 MB
+
|align="center"|1024
||8 MB
+
|align="center"|1024
 
|-
 
|-
||Default DRAM
+
||'''Dimensions'''
|| 20 MB
+
|align="center"|1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm)
|| 32 MB
+
|align="center"|1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm)
||32 MB
+
|align="center"|1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm)
 
|-
 
|-
||NVRAM
+
||'''Operating Temperature Range'''
|| 256 KB
+
|align="center"|32 to 104 Deg. F (0 to 40 Deg. C)
|| 256 KB
+
|align="center"|32 to 104 Deg. F (0 to 40 Deg. C)
|| 512 KB
+
|align="center"|32 to 104 Deg. F (0 to 40 Deg. C)
 
|-
 
|-
||Console Port
+
||'''Storage Temperature Range'''
||DB-25
+
|align="center"| -40 to 167 Deg. F (-40 to 75 Deg. C)
|| DB-25
+
|align="center"| -40 to 167 Deg. F (-40 to 75 Deg. C)
|| RJ-45
+
|align="center"| -40 to 167 Deg. F (-40 to 75 Deg. C)
 
|-
 
|-
||Auxiliary Port
+
||'''Relative Humidity'''
||No
+
|align="center"|10% to 90%, noncondensing
||No
+
|align="center"|10% to 90%, noncondensing
||RJ-45
+
|align="center"|10% to 90%, noncondensing
 
|-
 
|-
||FE Management Interface
+
|}
||Yes
+
 
||Yes
+
'''Note:''' Older versions of the Supervisor III came with NFFC's or NFFC-II's, instead of the newer NFFC-A and
||Yes
+
NFFC-IIA's. Some even older ones even came without a NFFC at all, and these models were quickly EOS'd.
 +
 
 +
{| border = "1"
 +
||'''Part Number '''
 +
|align="center"|'''Description'''
 +
|align="center"|'''Software Req'd'''
 +
||  
 
|-
 
|-
||EtherChannel on Uplinks
+
||'''WS-X5005'''
|| No
+
|align="center"|Supervisor I (100BaseFX, Singlemode)
||FEC
+
|align="center"| 1.1
||FEC
+
||  
 
|-
 
|-
||Max # of MAC Addresses
+
||'''WS-X5006'''
||16000
+
|align="center"|Supervisor I (100BaseFX, Multimode)
||16000
+
|align="center"| 1.1
||16000
+
||  
 
|-
 
|-
||Max VLANs
+
||'''WS-X5009'''
||1024
+
|align="center"|Supervisor I (100BaseTX)
||1024
+
|align="center"| 1.1
||1024
+
||  
 
|-
 
|-
||Dimensions (H/W/D)
+
||'''WS-X5505 '''
||1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm)
+
|align="center"|Supervisor II (100BaseFX, Singlemode)
||1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm)
+
|align="center"|2.2 (1)
||1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm)
+
||  
 
|-
 
|-
||Operating Temperature Range
+
||'''WS-X5506'''
||32 to 104° F (0 to 40° C)
+
|align="center"|Supervisor II (100BaseFX, Multimode)
||32 to 104° F (0 to 40° C)
+
|align="center"|2.2 (1)
||32 to 104° F (0 to 40° C)
+
||  
 
|-
 
|-
||Storage Temperature Range
+
||'''WS-X5509'''
||-40 to 167° F (-40 to 75° C)
+
|align="center"|Supervisor II (100BaseTX)
||-40 to 167° F (-40 to 75° C)
+
|align="center"|2.2 (1)
||-40 to 167° F (-40 to 75° C)
+
||  
 
|-
 
|-
||Relative Humidity
+
||'''WS-X5530-E1 '''
||10% to 90%, noncondensing
+
|align="center"|Supervisor III
||10% to 90%, noncondensing
+
|align="center"|3.1(1)
||10% to 90%, noncondensing
+
||
 +
|-
 +
||'''WS-X5530-E2'''
 +
|align="center"|Supervisor III with NFFC
 +
|align="center"|4.1(1)
 +
||
 +
|-
 +
||'''WS-X5530-E2A'''
 +
|align="center"|Supervisor III with NFFC-A
 +
|align="center"|4.5(4)
 +
||
 +
|-
 +
||'''WS-X5530-E3 '''
 +
|align="center"|Supervisor III with NFFC II
 +
|align="center"|4.3(1)
 +
||
 +
|-
 +
||'''WS-X5530-E3A '''
 +
|align="center"|Supervisor III with NFFC II-A
 +
|align="center"|4.5(4)
 +
||
 +
|-
 +
||'''WS-X5534-E1-GESX'''
 +
|align="center"|Supervisor III F (1000BaseSX)
 +
|align="center"|4.3(1a)
 +
||
 +
|-
 +
||'''WS-X5534-E1-GELX'''
 +
|align="center"|Supervisor III F (1000BaseLX)
 +
|align="center"|4.3(1a)
 +
||
 +
|-
 +
||'''WS-X5540 '''
 +
|align="center"|Supervisor II G
 +
|align="center"| 5.1(1a)
 +
||
 +
|-
 +
||'''WS-X5550'''
 +
|align="center"|Supervisor III G
 +
|align="center"| 5.1(1a)
 +
||  
 
|-
 
|-
 
|}
 
|}
 +
 +
'''Supervisor Redundancy'''
 
<br/><br/>
 
<br/><br/>
'''Note:''' Older versions of the Supervisor III came with NFFC's or NFFC-II's, instead of the newer NFFC-A and
+
{| border = "1"
NFFC-IIA's. Some even older ones even came without a NFFC at all, and these models were quickly EOS'd.
+
||Supervisor Redundancy requires a 5500 series chassis (5505, 5509, 5500) and one of the following
Gigabit Etherchannel is not supported on any Supervisor, and never will. GEC is only supported on the 9-port
+
|-
GE line card (WS-X5410).
+
||combinations:
 +
|-
 +
||Two Supervisor Engine IIs
 +
|-
 +
||Two Supervisor Engine IIIs with EARL 1
 +
|-
 +
||Two Supervisor Engine IIIs with the NFFC/NFFC-A
 +
|-
 +
||Two Supervisor Engine IIIs with the NFFC II/II-A
 +
|-
 +
||Two Supervisor Engine III Fs with EARL 1
 +
|-
 +
||Two Supervisor Engine III Fs with NFFC/NFFC-A  
 +
|-
 +
||Two Supervisor Engine III Fs with NFFC II/II-A
 +
|-
 +
||Two Supervisor Engine II Gs without the RSFC
 +
|-
 +
||Two Supervisor Engine II Gs with RSFC
 +
|-
 +
||Two Supervisor Engine III Gs without the RSFC
 +
|-
 +
||Two Supervisor Engine III Gs with RSFC
 +
|-
 +
||One Supervisor Engine II G with the RSFC and one Supervisor Engine II G without the RSFC
 +
|-
 +
||One Supervisor Engine III G with the RSFC and one Supervisor Engine III G without the RSFC
 +
|-
 +
|}
 +
 
 +
 +
The following redundant configurations are supported, but with the caveat that MLS is not supported for
 +
traffic on the redundant supervisor engine ports when the supervisor engine in standby mode has the NFFC
 +
or NFFCII. MLS is supported for traffic on the redundant supervisor engine ports when the supervisor engine
 +
in standby mode has the NFFC-A or NFFCII-A.
 +
 
 +
 
 +
{| border = "1"
 +
||Supervisor Engine III with NFFC and Supervisor Engine III with NFFC-A
 +
|-
 +
||Supervisor Engine III with NFFC II and Supervisor Engine III with NFFC II-A
 +
|-
 +
||Supervisor Engine III F with NFFC and Supervisor Engine III F with NFFC-A
 +
|-
 +
||Supervisor Engine III F with NFFC II and Supervisor Engine III F with NFFC II-A
 +
|-
 +
|}

Revision as of 14:30, 24 September 2008

Feature Supervisor III Supervisor III F Supervisor III G
EOS Status July 30, 2003 April 15, 2000 July 30, 2003
Chassis Support All but 5002 with 155W Power All All
Redundant Supervisors Yes Yes Yes
Processor 150MHz R4700 RISC IDT RISC (Similar to SupII) 37.5MHz Motorola MCF5102
Modular NFFC-II Yes (A and II-A)* Yes Integrated
Modular RSFC No No Yes
Fixed Uplinks None (2)1000BaseSX (2)1000BaseLX (2)GBIC
Modular Uplinks No No (2/4)100BaseTX, (2/4)100BaseFX, (2)1000BaseSX, (2)1000BaseLX No No
Backplane Connection 3.6 Gbps 3.6 Gbps 3.6 Gbps
PCMCIA Flash Yes No No
Default Flash 8 MB 8 MB 8 MB
Default DRAM 64 MB 32 MB 32 MB
NVRAM 512 KB 512 KB 512 KB
Console Port RJ-45 RJ-45 RJ-45
Auxiliary Port RJ-45 RJ-45 RJ-45
FE Management Interface Yes Yes Yes
EtherChannel on Uplinks FEC No No FEC No No
Max # of MAC Addresses 16000 16000 16000
Max VLANs 1024 1024 1024
Dimensions 1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm) 1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm) 1.2 x 14.4 x 16 in. (3 x 35.6 x 40.6 cm)
Operating Temperature Range 32 to 104 Deg. F (0 to 40 Deg. C) 32 to 104 Deg. F (0 to 40 Deg. C) 32 to 104 Deg. F (0 to 40 Deg. C)
Storage Temperature Range -40 to 167 Deg. F (-40 to 75 Deg. C) -40 to 167 Deg. F (-40 to 75 Deg. C) -40 to 167 Deg. F (-40 to 75 Deg. C)
Relative Humidity 10% to 90%, noncondensing 10% to 90%, noncondensing 10% to 90%, noncondensing

Note: Older versions of the Supervisor III came with NFFC's or NFFC-II's, instead of the newer NFFC-A and NFFC-IIA's. Some even older ones even came without a NFFC at all, and these models were quickly EOS'd.

Part Number Description Software Req'd
WS-X5005 Supervisor I (100BaseFX, Singlemode) 1.1
WS-X5006 Supervisor I (100BaseFX, Multimode) 1.1
WS-X5009 Supervisor I (100BaseTX) 1.1
WS-X5505 Supervisor II (100BaseFX, Singlemode) 2.2 (1)
WS-X5506 Supervisor II (100BaseFX, Multimode) 2.2 (1)
WS-X5509 Supervisor II (100BaseTX) 2.2 (1)
WS-X5530-E1 Supervisor III 3.1(1)
WS-X5530-E2 Supervisor III with NFFC 4.1(1)
WS-X5530-E2A Supervisor III with NFFC-A 4.5(4)
WS-X5530-E3 Supervisor III with NFFC II 4.3(1)
WS-X5530-E3A Supervisor III with NFFC II-A 4.5(4)
WS-X5534-E1-GESX Supervisor III F (1000BaseSX) 4.3(1a)
WS-X5534-E1-GELX Supervisor III F (1000BaseLX) 4.3(1a)
WS-X5540 Supervisor II G 5.1(1a)
WS-X5550 Supervisor III G 5.1(1a)

Supervisor Redundancy

Supervisor Redundancy requires a 5500 series chassis (5505, 5509, 5500) and one of the following
combinations:
Two Supervisor Engine IIs
Two Supervisor Engine IIIs with EARL 1
Two Supervisor Engine IIIs with the NFFC/NFFC-A
Two Supervisor Engine IIIs with the NFFC II/II-A
Two Supervisor Engine III Fs with EARL 1
Two Supervisor Engine III Fs with NFFC/NFFC-A
Two Supervisor Engine III Fs with NFFC II/II-A
Two Supervisor Engine II Gs without the RSFC
Two Supervisor Engine II Gs with RSFC
Two Supervisor Engine III Gs without the RSFC
Two Supervisor Engine III Gs with RSFC
One Supervisor Engine II G with the RSFC and one Supervisor Engine II G without the RSFC
One Supervisor Engine III G with the RSFC and one Supervisor Engine III G without the RSFC


The following redundant configurations are supported, but with the caveat that MLS is not supported for traffic on the redundant supervisor engine ports when the supervisor engine in standby mode has the NFFC or NFFCII. MLS is supported for traffic on the redundant supervisor engine ports when the supervisor engine in standby mode has the NFFC-A or NFFCII-A.


Supervisor Engine III with NFFC and Supervisor Engine III with NFFC-A
Supervisor Engine III with NFFC II and Supervisor Engine III with NFFC II-A
Supervisor Engine III F with NFFC and Supervisor Engine III F with NFFC-A
Supervisor Engine III F with NFFC II and Supervisor Engine III F with NFFC II-A