Difference between revisions of "Gigabit Ethernet Transceiver Modules Compatibility Matrix"
From NesevoWiki
Jump to navigationJump to search| Line 119: | Line 119: | ||
|} | |} | ||
| − | |||
| − | |||
{| border = "1" | {| border = "1" | ||
Revision as of 12:41, 13 September 2012
Catalyst Express 500 Support
| Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
| DOM Support | Cisco IOS Release | |||
| Catalyst Express 500 | WS-CE500-24LC WS-CE500-24PC WS-CE500G-12TC |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(25)FY |
| Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
| DOM Support | Cisco IOS Release | |||
| Catalyst Express 520 | WS-CE520-8PC-K9 | GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(35)EX |
| WS-CE520-24LC-K9 WS-CE520-24PC-K9 WS-CE520G-24TC-K9 |
GLC-SX-MM GLC-LH-SM GLC-SX-MMD GLC-LH-SMD |
— | 12.2(37)EX |
Metro Ethernet Support
| Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | ||
| DOM Support | Cisco IOS Release | ||||
| Cisco ME 2400 | ME-2400-24TS-A | GLC-T(10/100/1000) | — | 12.2(25)EX | |
| ME-2400-24TS-D | GLC-SX-MM | ||||
| GLC-LH-SM | |||||
| GLC-ZX-SM | |||||
| GLC-BX-D | 12.2(44)SE | 12.2(25)EX | |||
| GLC-BX-U | |||||
| CDWM SFP |
| Platform | Switch or Module | Transceiver Module | Minimum Software Release Required | |
| DOM Support | Cisco IOS Release | |||
| Cisco ME 3400 | ME-3400-24TS-A | GLC-T (10/100/1000) | — | 12.2(25)EX |
| ME-3400-24TS-D | GLC-SX-MM | |||
| GLC-LH-SM | ||||
| GLC-SX-MMD | 12.2(46)SE | 12.2(25)EX | ||
| GLC-LH-SMD | ||||
| GLC-ZX-SM | 12.2(46)SE | 12.2(25)EX | ||
| GLC-BX-D | 12.2(44)SE | 12.2(25)EX | ||
| GLC-BX-U | ||||
| CWDM SFP | ||||
| DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
| DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
| SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
| SFP-GE-L | ||||
| SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
| GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
| ME-3400G-12CS-A | GLC-T (10/100/1000) | — | 12.2(25)SEG1 | |
| ME-3400G-12CS-D | GLC-SX-MM | |||
| GLC-LH-SM | ||||
| GLC-SX-MMD | 12.2(46)SE | 12.2(25)SEG1 | ||
| GLC-LH-SMD | ||||
| GLC-ZX-SM | 12.2(46)SE | 12.2(25)SEG1 | ||
| GLC-BX-D | 12.2(44)SE | |||
| GLC-BX-U | 12.2(44)SE | |||
| CWDM SFP | 12.2(44)SE | 12.2(25)SEG1 | ||
| DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
| DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
| SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
| SFP-GE-L | ||||
| SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
| GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
| ME-3400G-2CS-A | GLC-T (10/100/1000) | — | 12.2(35)SE1 | |
| GLC-SX-MM | — | |||
| GLC-LH-SM | — | |||
| GLC-SX-MMD | 12.2(46)SE | 12.2(35)SE1 | ||
| GLC-LH-SMD | ||||
| GLC-ZX-SM | 12.2(46)SE | 12.2(35)SE1 | ||
| GLC-BX-D | 12.2(44)SE | |||
| GLC-BX-U | 12.2(44)SE | |||
| CWDM SFP | 12.2(44)SE | 12.2(35)SE1 | ||
| DWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
| DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
| SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
| SFP-GE-L | ||||
| SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
| GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
| ME-3400-24FS-A | GLC-T (10/100/1000) | — | 12.2(40)SE | |
| GLC-SX-MM | — | |||
| GLC-LH-SM | — | |||
| GLC-ZX-SM | 12.2(46)SE | |||
| GLC-SX-MMD | 12.2(46)SE | |||
| GLC-LH-SMD | 12.2(46)SE | |||
| GLC-BX-D | 12.2(44)SE | 12.2(40)SE | ||
| GLC-BX-U | ||||
| CWDM SFP | 12.2(44)SE | 12.2(40)SE | ||
| DWDM SFP | 12.2(50)SE | 12.2(40)SE | ||
| DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
| SFP-GE-S | 12.2(46)SE | 12.2(46)SE | ||
| SFP-GE-L | ||||
| SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
| GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE | ||
| ME-3400E-24TS-M | GLC-T (10/100/1000) | — | 12.2(44)EY | |
| ME-3400EG-2CS-A | GLC-SX-MM | |||
| ME-3400EG-12CS-M | GLC-LH-SM | |||
| GLC-SX-MMD | 12.2(44)EY | 12.2(44)EY | ||
| GLC-LH-SMD | ||||
| GLC-ZX-SM | ||||
| GLC-BX-D | ||||
| GLC-BX-U | ||||
| CWDM SFP | ||||
| DWDM SFP | ||||
| SFP-GE-S | ||||
| SFP-GE-L | ||||
| SFP-GE-Z | ||||
| DWDM SFP (add.) | 12.2(50)SE | 12.2(50)SE | ||
| SFP-GE-T (10/100/1000) | — | 12.2(46)SE | ||
| GLC-EX-SMD | 12.2(52)SE | 12.2(52)SE |