==Supervisor engines== | ==Supervisor engines== | ||
− | Both, the Cisco7609 and the Cisco7609-S router | + | Both, the Cisco7609 and the Cisco7609-S router has nine vertical slots being numbered from right to left and measures 21 rack units (21 RU).<br/> |
− | While the supported supervisor engine 2 (see below) is installed in slot 1 and an optional redundant supervisor engine 2 in slot 2, the supported supervisor engine 720, supervisor engine 32 and route switch processor 720 are installed in slot 5 (first supervisor engine)and slot 6 (optional redundant supervisor engine).<br/> | + | While the supported supervisor engine 2 (see below) is installed in slot 1 and an optional redundant supervisor engine 2 in slot 2, the supported supervisor engine 720, supervisor engine 32 and route switch processor 720 are installed in slot 5 (first supervisor engine)and slot 6 (optional redundant supervisor engine).<br/><br/> |
− | ''!!! Note: When installing a redundant supervisor engine, both supervisor engines must be identical.''<br/> | + | '''''!!! Note: When installing a redundant supervisor engine, both supervisor engines must be identical.'''''<br/> |
− | ''!!! Note: The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by.''<br/> | + | '''''!!! Note: The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by.'''''<br/><br/> |
− | If a redundant supervisor engine is not required, all free slots can be equipped with any supported cisco7600 series / catalyst 6500 series module.<br/> | + | |
+ | If a redundant supervisor engine is not required, all free slots can be equipped with any supported cisco7600 series / catalyst 6500 series module.<br/><br/> | ||
+ | |||
'''Supported supervisor engines in the Cisco7609 router'''<br/> | '''Supported supervisor engines in the Cisco7609 router'''<br/> | ||
*Supervisor engine 2<br/>''!!! To be installed in slot 1 (first supervisor engine) and in slot 2 (optional redundant supervisor engine).''<br/> | *Supervisor engine 2<br/>''!!! To be installed in slot 1 (first supervisor engine) and in slot 2 (optional redundant supervisor engine).''<br/> | ||
− | **WS-X6K-S2-PFC2<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-PFC2]]<br/> |
− | **WS-X6K-S2-MSFC2<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2-MSFC2]]<br/> |
− | **WS-X6K-S2U-MSFC2<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-X6K-S2U-MSFC2]] <br/> |
*Supervisor engine 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | *Supervisor engine 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | ||
− | **WS-SUP720<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]] <br/> |
− | **WS-SUP720-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]] <br/> |
− | **WS-SUP720-3BXL<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]] <br/> |
''!!!Note: The Supervisor Enigne 720 has two GBIC uplink ports and one 10/100/1000 Tx port. Only two of the three ports can be active at any one time.''<br/> | ''!!!Note: The Supervisor Enigne 720 has two GBIC uplink ports and one 10/100/1000 Tx port. Only two of the three ports can be active at any one time.''<br/> | ||
*Supervisor engine 32<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | *Supervisor engine 32<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | ||
− | **WS-SUP32-GE-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B]] <br/> |
− | **WS-SUP32-10GE-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]] <br/> |
*Route switch processor 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | *Route switch processor 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | ||
Line 31: | Line 33: | ||
*Supervisor engine 32<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | *Supervisor engine 32<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | ||
− | **WS-SUP32-GE-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-GE-3B]] <br/> |
− | **WS-SUP32-10GE-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP32-10GE-3B]] <br/> |
*Supervisor engine 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | *Supervisor engine 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | ||
− | **WS-SUP720<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720]]<br/> |
− | **WS-SUP720-3B<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3B]]<br/> |
− | **WS-SUP720-3BXL<br/> | + | ** [[Cisco catalyst 6000 / 6500 series supervisor engines | WS-SUP720-3BXL]]<br/> |
*Route switch processor 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | *Route switch processor 720<br/>''!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).''<br/> | ||
Line 93: | Line 95: | ||
==Fan trays== | ==Fan trays== | ||
− | '''Supported fan trays in the | + | Both, the Cisco7609 and the Cisco7609-S router require two fan modules, that are both installed on the front of the chassis above the module slots.<br/> |
− | + | ||
− | + | '''Supported fan trays in the Cisco7609 router'''<br/> | |
*high speed fan module<br/> | *high speed fan module<br/> | ||
− | **FAN-MOD- | + | **FAN-MOD-09<br/> |
− | |||
− | '''Supported fan trays in the | + | '''Supported fan trays in the Cisco7609-S router'''<br/> |
*high speed fan module<br/> | *high speed fan module<br/> | ||
− | **FAN-MOD- | + | **FAN-MOD-9SHS<br/> |
− | ''!!! Note: | + | ''!!! Note: Both high speed fans, the FAN-MOD-09 and the FAN-MOD-9SHS will work in the Cisco7609-S chassis. With the FAN-MOD-9SHS being white, the colour would be the only difference.'' |
Latest revision as of 09:49, 8 June 2011
Supervisor engines
Both, the Cisco7609 and the Cisco7609-S router has nine vertical slots being numbered from right to left and measures 21 rack units (21 RU).
While the supported supervisor engine 2 (see below) is installed in slot 1 and an optional redundant supervisor engine 2 in slot 2, the supported supervisor engine 720, supervisor engine 32 and route switch processor 720 are installed in slot 5 (first supervisor engine)and slot 6 (optional redundant supervisor engine).
!!! Note: When installing a redundant supervisor engine, both supervisor engines must be identical.
!!! Note: The GBIC uplink ports are fully functional on the redundant supervisor engine in stand by.
If a redundant supervisor engine is not required, all free slots can be equipped with any supported cisco7600 series / catalyst 6500 series module.
Supported supervisor engines in the Cisco7609 router
- Supervisor engine 2
!!! To be installed in slot 1 (first supervisor engine) and in slot 2 (optional redundant supervisor engine).
- Supervisor engine 720
!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
!!!Note: The Supervisor Enigne 720 has two GBIC uplink ports and one 10/100/1000 Tx port. Only two of the three ports can be active at any one time.
- Supervisor engine 32
!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
- Route switch processor 720
!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
- RSP720-3C-GE
- RSP720-3CXL-GE
- RSP720-3C-GE
Supported supervisor engines in the Cisco7609-S router
- Supervisor engine 32
!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
- Supervisor engine 720
!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
- Route switch processor 720
!!! To be installed in slot 5 (first supervisor engine) and in slot 6 (optional redundant supervisor engine).
- RSP720-3C-GE
- RSP720-3CXL-GE
- RSP720-3C-GE
!!! Note: the supervisor engine 2 is not longer supported in the Cisco7609-S router.
Power supplies and power entry modules
Both, the Cisco7609 and the Cisco7609-S router have two power supply slots on the front of the chassis, with the power supply 1 being installed on the left and the optional redundant power supply 2 being installed in the right one of the two slots.
Supported power supplies in the Cisco7609 router
- 2500 watt DC-input power supply
- WS-CDC-2500W
- WS-CDC-2500W
No power entry module is needed when using a WS-CDC-2500W
- 3000 watt AC-input power supply
- WS-CAC-3000W
- WS-CAC-3000W
No power entry module is needed when using a WS-CAC-3000W
- 4000 watt AC-input power supply
- WS-CAC-4000W-US1
- WS-CAC-4000W-US1
No power entry module is needed when using a WS-CAC-4000W-US1/6
- 4000 watt DC-input power supply
- PWR-4000-DC
- PWR-4000-DC
No power entry module is needed when using a PWR-4000-DC
- 6000 watt AC-input power supply
- WS-CAC-6000W
- WS-CAC-6000W
No power entry module is needed when using a WS-CAC-6000W
- 6000 watt DC-input power supply
- PWR-6000-DC
- PWR-6000-DC
No power entry module is needed when using a PWR-6000-DC
Supported power supplies in the Cisco7609-S router
- 4000 watt AC-input power supply
- WS-CAC-4000W-US1
- WS-CAC-4000W-US1
No power entry module is needed when using a WS-CAC-4000W-US1/6
- 4000 watt DC-input power supply
- PWR-4000-DC
- PWR-4000-DC
No power entry module is needed when using a PWR-4000-DC
- 6000 watt AC-input power supply
- WS-CAC-6000W
- WS-CAC-6000W
No power entry module is needed when using a WS-CAC-6000W
- 6000 watt DC-input power supply
- PWR-6000-DC
- PWR-6000-DC
No power entry module is needed when using a PWR-6000-DC
Fan trays
Both, the Cisco7609 and the Cisco7609-S router require two fan modules, that are both installed on the front of the chassis above the module slots.
Supported fan trays in the Cisco7609 router
- high speed fan module
- FAN-MOD-09
- FAN-MOD-09
Supported fan trays in the Cisco7609-S router
- high speed fan module
- FAN-MOD-9SHS
- FAN-MOD-9SHS
!!! Note: Both high speed fans, the FAN-MOD-09 and the FAN-MOD-9SHS will work in the Cisco7609-S chassis. With the FAN-MOD-9SHS being white, the colour would be the only difference.